background image

when connects to computer: 
<1> Transmission format: serial asynchronous 
<2>Serial communication protocol: Baud rat:600, data units: 8 units, starting 

unit: 1 unit, ending unit: 1unit 

<3> Data format: starting spaces  data    symbol    ending    enter 
                                    2unit          7units          3unit            1 unit      1 unit 
<4> Calibration: no calibration 
<5> Output pins content (9-core socket): 2 pins: RXD   3 pins: TXD   
5pins: GND 
<6> Computer can control balance though RS232. The orders to balance are: 

           1BH+70H: sending data 
                      1BH+71H: calibration (like “CAL”)             

1BH+73H: Units change 

                      1BH+74H: Tare 
 

4.

 

Structure

 

   
   





 
 
 
 

 

 
(1) Scale pan   (2) Display window   (3) Level indicate   (4) Counting indicate    
(5) lb indicate   (6) kg indicate      (7) CAL   (8) COUNT   (9) TARE    
(10) PRINT          (11) UNIT                (12) ON/OFF switch      (13) Data output    
(14) Power line   (15) Level adjust 
 