G&G CYGG-080 Instructions For Use Manual Download Page 19

15

Particulate Pollutants

 REPLACEMENT 

PARTS

If you need to replace any part or assembly, please contact 

G&G

filtration, s.r.o.

, or the company that implemented the filtration unit, to

after agreement, arranged delivery and assembly of the required component.

DEMONTAGE AND

LIKVIDATION

When  disassembling  the  device,  follow  the  steps  opposite  to  those  described  in 

the  INSTALLATION  AND  REPLACEMENT  chapter.  If  you  are  unsure  of  the 

procedure, contact the unit manufacturer or call a specialist company.

Due  to  the  nature  of  the  working  conditions,  which  vary  from  application  to 

application, it is not possible to determine the lifetime of the cyclone in general. 

However, before disposing of the cyclone and its parts, render them unusable.
When disposing of the unit parts, the instructions of the manufacturers of the 

individual components as well as the relevant national regulations on waste 

disposal must be observed. Individual
We recommend that you have the components of the device disposed of at a 
specialised disposal facility.

6

ǀ

 DOCUMENTATION OF THE MANUFACTURER AND 

SUBCONTRACTORS

ADDED

DOCUMENTATION

The following manufacturer's documentation is supplied with this filtration device

and subcontractors:

- delivery note (handed over on delivery)

- declaration of conformity

- manufacturers' manuals for selected components
- electrical documentation

- production documentation (drawings, etc.)

7

ǀ

 WARRANTY CONDITIONS

Summary of Contents for CYGG-080

Page 1: ...CYCLONE SEPARATOR Instructions for use...

Page 2: ...Manual version v4 Date created 2023 11 08...

Page 3: ...NTS 7 PROHIBITED ACTIVITIES 7 safety instructions for operation and maintenance 8 RESIDUAL RISKS 8 4 INSTALLATION AND COMMISSIONING 10 WORKING ENVIRONMENT 10 OPERATING SPACE 10 AVAILABILITY 10 placeme...

Page 4: ...structions in this manual to ensure not only ease of use but also optimum use and longevity of the equipment Do not operate the equipment until you are thoroughly familiar with all the instructions pr...

Page 5: ...ABOUT THE INSTRUCTION 1...

Page 6: ...ht of the equipment supplied is indicated on the equipment s nameplate Lift the load with the lifting device and transport it to the designated unpacking or storage location The delivered equipment ma...

Page 7: ...pecified above Furthermore it is forbidden to operate them with components other than those with which they were supplied Cyclone separators must not be operated in a different power range than that s...

Page 8: ...mple model of a cyclone The supplied models consist of the same components differing only in size 1 Cyclone body cylindrical part 5 Input flange 2 Cyclone body conical part 6 Output flange 3 Expansion...

Page 9: ...ed or removed The selection of a particular model of cyclone separator its features and equipment is a matter of commercial negotiation between the manufacturer and the operator and this manual does n...

Page 10: ...6 TECHNICAL DATA EXIT CONCENTRATION The guaranteed dust removal rate is between 70 95 depending on the type of dust and the extraction conditions LABELS ON FACILITIES Production label...

Page 11: ...ompany that implements cyclone in its technology or the operator must ensure the following must clearly define the scope of responsibilities and competencies of the personnel designated for installati...

Page 12: ...the nature of the work to be performed such as flame resistant and dielectric work suits steel toed work boots gloves helmets safety glasses ear protectors and respirators depending on local condition...

Page 13: ...they are risks that remain even when all preventive and protective measures have been considered and implemented HAZARD Electric shock during installation maintenance or servicing of electrical parts...

Page 14: ...Explosion due to non compliance with the maximum temperature of filtered particulates in the case of explosive dusts or mixtures PROTECTION The model of the filter unit is designed for the environmen...

Page 15: ...material according to the operator s internal regulations or legislation valid in the country of installation of the filter unit 2 Visually check if any parts of the unit have been damaged during tra...

Page 16: ...parts conductively connected The unit shall be prevented from unexpected start up according to the applicable national standards of the country of operation and shall be equipped with a lockable shut...

Page 17: ...with the filter unit switched off Regularly check the insulation condition of all cables and the grounding condition In case of any damage contact the electrical maintenance personnel immediately Che...

Page 18: ...the filter outlet Dirt leaks through the seal Check the tightening of the fixing plates Residual drift value TZL is too high Low extraction power and poor air rotation inside the cyclone and thus low...

Page 19: ...e to determine the lifetime of the cyclone in general However before disposing of the cyclone and its parts render them unusable When disposing of the unit parts the instructions of the manufacturers...

Page 20: ...RRANTY COVERS hidden defects in the material demonstrable design defects Defects covered by the warranty must be reported in writing to the manufacturer s service department Special cases can only be...

Page 21: ...ent handling by unprofessional intervention by connecting or reconnecting to the wrong type or voltage of electricity normal mechanical wear and tear etc Other warranty conditions can be agreed in the...

Page 22: ...g the dust container P 1 X B2 Inspection of the inner part of the cyclone and removal of sediments 1 X B3 Checking the cyclone hopper flanges for leaks 1 X B4 Inspection and repair of corroded parts o...

Page 23: ...15...

Page 24: ...G G filtration CZ s r o Hrub nova 1903 9 664 51 lapanice Czech Republic...

Reviews: