Technical data
110
· G&D DP1.2-Vision-IP-Fiber
Features of transmission modules
MULTIMODE TRANSMISSION MODULE
Data transmission
Type:
fibre optics (2 glass fibres)
Interface type:
LC duplex
Cable length (max.)
Multimode 50/125
μ
m,
Class OM2:
550 metres (fibres with 500 MHz*km),
500 metres (fibres with 400 MHz*km)
Multimode 62,5/125
μ
m,
Class OM1:
220 metres (fibres with 160 MHz*km),
275 metres (fibres with 200 MHz*km)
Performance data
Wave length (
λ
):
850 nm (770 nm to 860 nm)
Optical power output (P
AVG
)
in 50 or 62,5
μ
m MMF:
-9,5 dBm to -3 dBm
Receiving sensitivity (P
MIN
):
-17 dBm
Sensitivity – Stressed (P
S
):
-13,5 dBm (50
μ
m MMF)
SINGLEMODE TRANSMISSION MODULE
Data transmission
Type:
fibre optics (2 glass fibres)
Interface type:
LC duplex
Cable length (max.)
Singlemode 9/125
μ
m,
Class OS1:
10 kilometres
Wave length (
λ
):
1310 nm (1270 nm to 1360 nm)
Performance data
Optical power output (P
AVG
)
in 9
μ
m SMF:
-9,5 dBm to -3 dBm
Receiving sensitivity (P
MIN
):
-19 dBm
Sensitivity – Stressed (P
S
):
-14,4 dBm
Summary of Contents for DP1.2-Vision-IP-Fiber
Page 118: ...Deutsch...
Page 119: ......
Page 236: ...English...
Page 237: ......
Page 238: ...English...
Page 239: ......