GSWP100W-EVBPA
GaN E-HEMT Wireless Power Transfer Evaluation Board
User’s Guide
_____________________________________________________________________________________________________________________
GSWP100W-EVBPA Rev 180529
© 2018 GaN Systems Inc.
www.gansystems.com 15
Please refer to the Evaluation Board/Kit Important Notice on page 26
Test points
To monitor the performance of PA, test points are provided and as described in Table 5. All test points
are available on the top side of the board, none are on the bottom side. The test points locations are
silkscreened on the PCB.
Table 5
: Test point description
Test point
Description
TP197
U90 input (PE29102 driver)
TP76
U6 input (PE29102 driver)
TP8
Q77 Gate voltage
TP81
Q76 Gate voltage
TP189
Q77 Drain voltage
TP82
Q76 Drain voltage
TP176
60V DC current detection
TP194
External oscillator monitor
Evaluation Bench Test Setup
The test bench setup for the GSWP100W-EVBPA EVB is shown in Figure 15. Ensure that the safety
precautions mentioned on page 2 are followed.
Figure 15 •
Bench setup
A recommended list equipment is provided below. Equipment with equivalent performance
specifications can be substituted. In all cases, ensure that it is well calibration.
•
DC power supply 100V/15A
•
TEK scope with current probe TCM0030A