TX5 Hybrid – GAMMA LED Vision
Page 22 of 24
Troubleshooting Problems
The following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work:
•
Check that the unit is plugged in to a working power connector.
•
Press the menu button to confirm that the unit is powered on. If the screen does
not light up, the unit has no power.
B. Not Responding to the DMX Controller
•
Check DMX cables to verify that they are plugged in and functional.
•
Check the DMX address and mode – does it match the address and mode patched
in the lighting console or software?
•
Plug the light directly into the DMX controller with a cable that you know is good.
Unplug all other lights – does it work?
•
Try to use another DMX controller.
4. Technical Specifications
•
Input Voltage: AC90-260V 50/60Hz
•
Light Source:
250W High Output White LED
•
Control Signal: DMX 512, master-slave and sound activated or auto operation
Control Channel: 16/18 DMX Channels USITT DMX-512
•
Power Consumption: 250w Dimensions: 270(D)*270(W)*470(H)mm
•
Packaging Size: 305(D)*305(W)*500(H)mm
•
Net Weight: 13.5kg