GAME CHANGER AUDIO PLASMA Rack Manual Download Page 22

https://docs.google.com/document/d/141nItTnFUzMIWo9ioGfFYkQFWgxTQXHcn-ZbwESh7CE/edit

1/2

Maximum output level 

+ 10 dBu  

 

 

FX loop send (1-3): 

 

Connector 

Tip-Sleeve ¼” Jack 

Impedance 

100 

 

Maximum output level 

+12 dBu (Line level) 

-6 dBu (Instrument level) 

 

 

FX loop return (1-3):

 

 

Connector 

Tip-Sleeve ¼” Jack 

Impedance 

1 M

 

Maximum input level 

+14 dBu 

 

 

MIDI in/out/through:

 

 

Connector 

5-pin DIN (180 degree) 

Type 

Op cally isolated input, RF 

ltered 

 

 

Expression pedal: 

 

Connector 

Tip-Ring-Sleeve ¼” (Wiper  p, CCW ring, CW sleeve) 

Type 

Designed for poten ometer-based expression pedals,  

RF 

ltered 

 

 

 

 

https://docs.google.com/document/d/141nItTnFUzMIWo9ioGfFYkQFWgxTQXHcn-ZbwESh7CE/edit

e) of 

MIDI CONTROL TABLE

20

 

 

 

 

Program Change message 

definitions 

 

Presets:

 

 

 

 

 

 

 

 

 

PC 

 

PRESET 1 

01 

 

 

PRESET 2 

02 

 

 

PRESET 3 

03 

 

 

PRESET 4 

04 

 

 

PRESET 5  

05 

 

 

PRESET 6  

06 

 

 

PRESET 7 

07 

 

 

PRESET 8 

08 

 

 

READ FRONT PANEL  

09 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continuous Control Message  
definitions 

 

 

      Potentiometers 

CC  

CC value range 

10 bit MSB / LSB 

 

 

 

 

 

 

EQ LOW 

14 

0 - 1023 

CC 14 / CC 46 

Low band eq se ng 

EQ MID 

15 

0 - 1023 

CC 15 / CC 47 

Mid band eq se ng 

EQ HI 

20 

0 - 1023 

CC 20 / CC 52 

Hi band eq se ng 

VOLUME 

07 

0 - 1023 

CC 07 / CC 39 

Master volume control 

RATE 

01 

0 - 1023 

CC 01 / CC 33 

Tremolo rate control 

DEPTH 

24 

0 - 1023 

CC 24 / CC 56 

Tremolo depth control 

INPUT GAIN 

21 

0 - 1023 

CC 21 / CC 53 

Drive gain control 

VOLTAGE 

22 

0 - 1023 

CC 22 / CC 54 

Voltage gain control 

BLEND 

23 

0 - 1023 

CC 23 / CC 55 

Blend between DRY and WET 

channels 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      Switches: 

CC 

CC value range

 

 

 

 

 

 

 

OVERSATURATE 

25 

0 - 63 = o

; 64 - 127 = on 

Ac va on of oversaturate mode 

CLEAN GATE 

26 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean gate mode 

PAD 

27 

0 - 63 = o

; 64 - 127 = on 

Ac va on of PAD 

DYNAMIC  

28 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Dynamic Tremolo 

TREMOLO 

29 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Tremolo mode 

SUSTAIN 

30 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Sustain mode 

CLEAN EQ 

31 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean tremolo 

CLEAN / DRIVE TOGGLE  85 

0 - 63 = clean; 64 - 127 = dirty 

Ac va on of lamp tremolo 

BYPASS 

86 

0 - 63 = o

; 64 - 127 = on 

Bypass PLASMA Rack 

MUTE 

87 

0 - 63 = o

; 64 - 127 = on 

Turn Volume O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program Change Message 

definitions 

 

Presets:

 

 

 

 

 

 

 

 

 

PC 

 

PRESET 1 

01 

 

 

PRESET 2 

02 

 

 

PRESET 3 

03 

 

 

PRESET 4 

04 

 

 

PRESET 5  

05 

 

 

PRESET 6  

06 

 

 

PRESET 7 

07 

 

 

PRESET 8 

08 

 

 

READ FRONT PANEL  

09 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switches: 

PC 

 

OVERSATURATE ON  

 

10 

 

 

OVERSATURATE OFF 

11 

 

 

OVERSATURATE TOGGLE 

12 

 

 

 

CLEAN GATE ON  

 

13 

 

 

CLEAN GATE OFF 

14 

 

 

CLEAN GATE TOGGLE 

15 

 

 

 

PAD ON  

 

16 

 

 

PAD OFF 

17 

 

 

PAD TOGGLE 

18 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switches: 

 

 

 

 

 

 

 

 

PC 

 

DYNAMIC ON 

 

19 

 

DYNAMIC OFF 

20 

 

DYNAMIC TOGGLE 

21 

 

 

TREMOLO ON 

 

22 

 

TREMOLO OFF 

23 

 

TREMOLO TOGGLE 

24 

 

 

SUSTAIN ON 

 

25 

 

SUSTAIN OFF 

26 

 

SUSTAIN TOGGLE 

27 

 

 

CLEAN EQ ON 

 

28 

 

CLEAN EQ OFF 

29 

 

CLEAN EQ TOGGLE 

30 

 

 

CLEAN/ DRIVE  

 

31 

 

CLEAN /DRIVE  

32 

 

CLEAN/DRIVE TOGGLE 

33 

 

 

RACK TRUE BYPASS ON 

 

34 

 

RACK TRUE BYPASS OFF 

35 

 

RACK TRUE BYPASS 

TOGGLE 

36 

 

 

MUTE ON 

 

37 

 

MUTE OFF 

38 

 

MUTE TOGGLE 

39 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
      Continuous Control Message  
      definitions 

 

 

      Potentiometers 

CC  

CC value range 

10 bit MSB / LSB 

 

 

 

 

 

 

EQ LOW 

14 

0 - 1023 

CC 14 / CC 46 

Low band eq se ng 

EQ MID 

15 

0 - 1023 

CC 15 / CC 47 

Mid band eq se ng 

EQ HI 

20 

0 - 1023 

CC 20 / CC 52 

Hi band eq se ng 

VOLUME 

07 

0 - 1023 

CC 07 / CC 39 

Master volume control 

RATE 

01 

0 - 1023 

CC 01 / CC 33 

Tremolo rate control 

DEPTH 

24 

0 - 1023 

CC 24 / CC 56 

Tremolo depth control 

INPUT GAIN 

21 

0 - 1023 

CC 21 / CC 53 

Drive gain control 

VOLTAGE 

22 

0 - 1023 

CC 22 / CC 54 

Voltage gain control 

BLEND 

23 

0 - 1023 

CC 23 / CC 55 

Blend between DRY and WET 

channels 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      Switches: 

CC 

CC value range

 

 

 

 

 

 

 

OVERSATURATE 

25 

0 - 63 = o

; 64 - 127 = on 

Ac va on of oversaturate mode 

CLEAN GATE 

26 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean gate mode 

PAD 

27 

0 - 63 = o

; 64 - 127 = on 

Ac va on of PAD 

DYNAMIC  

28 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Dynamic Tremolo 

TREMOLO 

29 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Tremolo mode 

SUSTAIN 

30 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Sustain mode 

CLEAN EQ 

31 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean tremolo 

CLEAN / DRIVE TOGGLE  85 

0 - 63 = clean; 64 - 127 = dirty 

Ac va on of lamp tremolo 

 

 

 

 

Program Change Message 

definitions 

 

Presets:

 

 

 

 

 

 

 

 

 

PC 

 

PRESET 1 

01 

 

 

PRESET 2 

02 

 

 

PRESET 3 

03 

 

 

PRESET 4 

04 

 

 

PRESET 5  

05 

 

 

PRESET 6  

06 

 

 

PRESET 7 

07 

 

 

PRESET 8 

08 

 

 

READ FRONT PANEL  

09 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
CC 119 is reserved for TREMOLO RATE sync between mul ple PLASMA Racks 
 
 

 
      Continuous Control Message  
      definitions 

 

 

      Potentiometers 

CC  

CC value range 

   

   

MSB / LSB

 

 

 

 

 

 

 

EQ LOW 

14 

0 - 1023 

CC 14 / CC 46 

Low band eq se ng 

EQ MID 

15 

0 - 1023 

CC 15 / CC 47 

Mid band eq se ng 

EQ HI 

20 

0 - 1023 

CC 20 / CC 52 

Hi band eq se ng 

VOLUME 

07 

0 - 1023 

CC 07 / CC 39 

Master volume control 

RATE 

01 

0 - 1023 

CC 01 / CC 33 

Tremolo rate control 

DEPTH 

24 

0 - 1023 

CC 24 / CC 56 

Tremolo depth control 

INPUT GAIN 

21 

0 - 1023 

CC 21 / CC 53 

Drive gain control 

VOLTAGE 

22 

0 - 1023 

CC 22 / CC 54 

Voltage gain control 

BLEND 

23 

0 - 1023 

CC 23 / CC 55 

Blend between DRY and WET 

channels 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      Switches: 

CC 

CC value range

 

 

 

 

 

 

 

OVERSATURATE 

25 

0 - 63 = o

; 64 - 127 = on 

Ac va on of oversaturate mode 

CLEAN GATE 

26 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean gate mode 

PAD 

27 

0 - 63 = o

; 64 - 127 = on 

Ac va on of PAD 

DYNAMIC  

28 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Dynamic Tremolo 

TREMOLO 

29 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Tremolo mode 

SUSTAIN 

30 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Sustain mode 

CLEAN EQ 

31 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean tremolo 

CLEAN / DRIVE TOGGLE  85 

0 - 63 = clean; 64 - 127 = dirty 

Ac va on of lamp tremolo 

BYPASS 

86 

0 - 63 = o

; 64 - 127 = on 

Bypass PLASMA Rack 

 
      Continuous Control Message  
      definitions 

 

 

      Potentiometers 

CC  

CC value range 

10 bit MSB / LSB 

 

 

 

 

 

 

EQ LOW 

14 

0 - 1023 

CC 14 / CC 46 

Low band eq se ng 

EQ MID 

15 

0 - 1023 

CC 15 / CC 47 

Mid band eq se ng 

EQ HI 

20 

0 - 1023 

CC 20 / CC 52 

Hi band eq se ng 

VOLUME 

07 

0 - 1023 

CC 07 / CC 39 

Master volume control 

RATE 

01 

0 - 1023 

CC 01 / CC 33 

Tremolo rate control 

DEPTH 

24 

0 - 1023 

CC 24 / CC 56 

Tremolo depth control 

INPUT GAIN 

21 

0 - 1023 

CC 21 / CC 53 

Drive gain control 

VOLTAGE 

22 

0 - 1023 

CC 22 / CC 54 

Voltage gain control 

BLEND 

23 

0 - 1023 

CC 23 / CC 55 

Blend between DRY and WET 

channels 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      Switches: 

CC 

CC value range

 

 

 

 

 

 

 

OVERSATURATE 

25 

0 - 63 = o

; 64 - 127 = on 

Ac va on of oversaturate mode 

CLEAN GATE 

26 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean gate mode 

PAD 

27 

0 - 63 = o

; 64 - 127 = on 

Ac va on of PAD 

DYNAMIC  

28 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Dynamic Tremolo 

TREMOLO 

29 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Tremolo mode 

SUSTAIN 

30 

0 - 63 = o

; 64 - 127 = on 

Ac va on of Sustain mode 

CLEAN EQ 

31 

0 - 63 = o

; 64 - 127 = on 

Ac va on of clean tremolo 

CLEAN / DRIVE TOGGLE  85 

0 - 63 = clean; 64 - 127 = dirty 

Ac va on of lamp tremolo 

BYPASS 

86 

0 - 63 = o

; 64 - 127 = on 

Bypass PLASMA Rack 

MUTE 

87 

0 - 63 = o

; 64 - 127 = on 

Turn Volume O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PLASMA Rack

Page 1: ...MANUAL...

Page 2: ...icians and engineers to break new ground PLASMA Rack is the result over 2 years of research and development dozens of prototypes and an incalculable amount of hard work We are all very happy with the...

Page 3: ...GE AND BLEND EQUALIZER VOLUME AND UTILITY BUTTONS SUSTAIN OVERSATURATE AND CLEAN GATE TREMOLO BACK PANEL MIDI CONTROLS EXPRESSION PEDAL INPUT DEFAULT BUTTON STATES CLEAN DIRTY TOGGLE AND FACTORY RESET...

Page 4: ...overdrive the PLASMA RACK uses a fly back coil transformer to express your instrument s live signal as a series of continuous high voltage discharges within a xenon filled tube In essence you are play...

Page 5: ...onse Built In Distortion Channel A special button combination lets you add some High Class Op Amp dirt to your Dry signal 3 FX Loops with switchable level control Modify the signal path by inserting e...

Page 6: ...es or multiple PLASMA Racks SUSTAIN turns on a compression circuit that prolongs the note s sustain in the PLASMA Tube OVERSATURATE creates overtones by overpowering the PLASMA Tube GAIN controls the...

Page 7: ...IN MIDI OUT can be configured as OUT THROUGH see page 11 SEND 3 SEND 2 SEND 1 RETURN 3 RETURN 2 RETURN 1 MIDI THROUGH ON OFF turns the device ON and OFF GROUND LIFT BALANCED OUT LINE BALANCED IN comb...

Page 8: ...e Mixing the DRY and WET signals lets you achieve more sound variations When BLEND is turned all the way to the left only the DRY audio can be heard in the output Gating EQ Tremolo set separately When...

Page 9: ...n to a warm bass track When the CLEAN EQ button is switched ON both WET and DRY signals will be filtered VOLUME Master Volume Control affects the output levels of DRY and WET signals POWER The POWER B...

Page 10: ...ality to melodic lines CLEAN GATE can also be used to eliminate Hum and noise from other pedals or effects in the signal chain Naturally the CLEAN GATE mode can be used when both DRY and WET signals a...

Page 11: ...ar monics produced by the Flickering PLASMA Tube DYNAMIC DYNAMIC mode is a special kind of Tremolo effect specifically designed for the PLASMA Rack In essence DYNAMIC Mode makes the Tremolo Depth sens...

Page 12: ...into the PLASMA Rack s MIDI OUT connector and the MIDI SEND button on the PLASMA Rack s front panel needs to be switched ON The MIDI OUT connector can also be configured as a MIDI OUT THROUGH for mor...

Page 13: ...Loop 3 will affect the WET Signal only after the PLASMA Tube 12 GROUND LIFT The ground lift switch disonnects the ground of all signal connectors from the AC Mains safety ground allowing to break grou...

Page 14: ...bination of knobs and buttons can be saved on one of PLASMA Rack s eight preset slots PRESET SLOTS 1 8 are indicated by 8 front panel buttons shown below To save a preset 1 Configure a Sound that you...

Page 15: ...Reassigning the EXP Input 1 Make sure that the PLASMA Rack is ON 2 PRESS and HOLD the PAD Button until it starts blinking 3 While PAD is blinking turn the desired knob to the MINIMUM position 4 Then...

Page 16: ...on 4 To Escape without saving PRESS the POWER Button NB Saving default button states will also save the CLEAN DIRTY Blend setting see next page Default Button States for Utility Settings The default s...

Page 17: ...n an Overdriven signal 3 To return to CLEAN Blend repeat the SUSTAIN CLEAN GATE Long Press FACTORY RESET To return to the Factory settings and erase all saved presets follow these steps 1 Switch the d...

Page 18: ...es performed by an Expression Pedal connected to RACK 1 will be repeated on RACK 2 ONLY if the MIDI SEND Button on RACK 1 is ON RACK 1 RACK 2 EXPRESSION PEDAL MIDI CONTROLLER M I D I O U T M I D I I N...

Page 19: ...edance 220 Maximum output level 7 dBu Balanced output Connector Male XLR Pin 2 Hot Type Mic Line input RF ltered true bypass to balanced output Unbalanced output Connector Tip Sleeve Jack Impedance 22...

Page 20: ...remolo Rate range 0 85 to 2600 Hz Depth control 0 100 in posi ve range or out nega ve range of phase between clean and distorted signals Tube Gas Xenon Discharge voltage 5 5 kV System performance Freq...

Page 21: ...roved by Gamechanger Audio could void the User s authority to operate the equipment CA This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme...

Page 22: ...ntrol DEPTH 24 0 1023 CC 24 CC 56 Tremolo depth control INPUT GAIN 21 0 1023 CC 21 CC 53 Drive gain control VOLTAGE 22 0 1023 CC 22 CC 54 Voltage gain control BLEND 23 0 1023 CC 23 CC 55 Blend between...

Page 23: ...the apparatus has been damaged in any way such as by being dropped exposed to rain liquid being spilled on it or otherwise does not operate normally Service There are no user serviceable parts inside...

Page 24: ......

Reviews: