MIDI CONTROLS

All parameters of the PLASMA Rack can be controlled with MIDI - via CC messages and 

via Program Change messages. 

Configuring the PLASMA Rack’s MIDI Tx(Transmit) an Rx(Receive) Channels:

1) Turn the PLASMA Rack OFF, using the front panel POWER button

2) PRESS and HOLD the CLEAN EQ and DYNAMIC buttons until they start blinking

3) Now you can configure the MIDI Tx Channel by tapping the OVERSATURATE button a 

specific number of times - for example, if you wish to set the Rack’s MIDI Tx channel to 

Channel Three, then tap the OVERSATURATE Button 3 times. 

4)To configure the PLASMA Rack’s MIDI Rx Channel - tap the CLEAN GATE button. 

For example - Rx Channel 4 would mean 4 taps on the CLEAN GATE button.

5) To SAVE press and hold the CLEAN EQ button until it blinking stops. 

6) To exit without saving press the DYNAMIC button.

Any combination of knobs and buttons can be saved on one of PLASMA Rack’s eight 

preset slots. 

PRESET SLOTS 1 - 8 are indicated by 8 front panel buttons shown below

To save a preset:

1) Configure a Sound that you wish to save on the PLASMA Rack 

This includes the positions of all rotary knobs and all sound-related buttons (excl. Power, MIDI 

Send, PAD, FX LOOP).*

2) PRESS and HOLD the MIDI SEND button until it starts blinking. 

3) You will see that the POWER button is ON, while the MIDI SEND and FX LOOP buttons are 

blinking (since preset slot 1 is indicated by the FX LOOP button)

Tap the MIDI SEND button to navigate through the remaining 7 Preset slots. 

4) When you’ve chosen one of the eight available Preset Slots, PRESS and HOLD the MIDI 

SEND button to save the Preset. 

5) To Escape before saving - PRESS the POWER button.

Settings saved as Presets can be recalled by MIDI Program Change messages 01 - 08.

Program Change Message 09 will return the PLASMA Rack to actual front panel settings.

13

*CLEAN/DRIVE Toggle and EXP Pedal assignment are also saved

Summary of Contents for PLASMA Rack

Page 1: ...MANUAL...

Page 2: ...icians and engineers to break new ground PLASMA Rack is the result over 2 years of research and development dozens of prototypes and an incalculable amount of hard work We are all very happy with the...

Page 3: ...GE AND BLEND EQUALIZER VOLUME AND UTILITY BUTTONS SUSTAIN OVERSATURATE AND CLEAN GATE TREMOLO BACK PANEL MIDI CONTROLS EXPRESSION PEDAL INPUT DEFAULT BUTTON STATES CLEAN DIRTY TOGGLE AND FACTORY RESET...

Page 4: ...overdrive the PLASMA RACK uses a fly back coil transformer to express your instrument s live signal as a series of continuous high voltage discharges within a xenon filled tube In essence you are play...

Page 5: ...onse Built In Distortion Channel A special button combination lets you add some High Class Op Amp dirt to your Dry signal 3 FX Loops with switchable level control Modify the signal path by inserting e...

Page 6: ...es or multiple PLASMA Racks SUSTAIN turns on a compression circuit that prolongs the note s sustain in the PLASMA Tube OVERSATURATE creates overtones by overpowering the PLASMA Tube GAIN controls the...

Page 7: ...IN MIDI OUT can be configured as OUT THROUGH see page 11 SEND 3 SEND 2 SEND 1 RETURN 3 RETURN 2 RETURN 1 MIDI THROUGH ON OFF turns the device ON and OFF GROUND LIFT BALANCED OUT LINE BALANCED IN comb...

Page 8: ...e Mixing the DRY and WET signals lets you achieve more sound variations When BLEND is turned all the way to the left only the DRY audio can be heard in the output Gating EQ Tremolo set separately When...

Page 9: ...n to a warm bass track When the CLEAN EQ button is switched ON both WET and DRY signals will be filtered VOLUME Master Volume Control affects the output levels of DRY and WET signals POWER The POWER B...

Page 10: ...ality to melodic lines CLEAN GATE can also be used to eliminate Hum and noise from other pedals or effects in the signal chain Naturally the CLEAN GATE mode can be used when both DRY and WET signals a...

Page 11: ...ar monics produced by the Flickering PLASMA Tube DYNAMIC DYNAMIC mode is a special kind of Tremolo effect specifically designed for the PLASMA Rack In essence DYNAMIC Mode makes the Tremolo Depth sens...

Page 12: ...into the PLASMA Rack s MIDI OUT connector and the MIDI SEND button on the PLASMA Rack s front panel needs to be switched ON The MIDI OUT connector can also be configured as a MIDI OUT THROUGH for mor...

Page 13: ...Loop 3 will affect the WET Signal only after the PLASMA Tube 12 GROUND LIFT The ground lift switch disonnects the ground of all signal connectors from the AC Mains safety ground allowing to break grou...

Page 14: ...bination of knobs and buttons can be saved on one of PLASMA Rack s eight preset slots PRESET SLOTS 1 8 are indicated by 8 front panel buttons shown below To save a preset 1 Configure a Sound that you...

Page 15: ...Reassigning the EXP Input 1 Make sure that the PLASMA Rack is ON 2 PRESS and HOLD the PAD Button until it starts blinking 3 While PAD is blinking turn the desired knob to the MINIMUM position 4 Then...

Page 16: ...on 4 To Escape without saving PRESS the POWER Button NB Saving default button states will also save the CLEAN DIRTY Blend setting see next page Default Button States for Utility Settings The default s...

Page 17: ...n an Overdriven signal 3 To return to CLEAN Blend repeat the SUSTAIN CLEAN GATE Long Press FACTORY RESET To return to the Factory settings and erase all saved presets follow these steps 1 Switch the d...

Page 18: ...es performed by an Expression Pedal connected to RACK 1 will be repeated on RACK 2 ONLY if the MIDI SEND Button on RACK 1 is ON RACK 1 RACK 2 EXPRESSION PEDAL MIDI CONTROLLER M I D I O U T M I D I I N...

Page 19: ...edance 220 Maximum output level 7 dBu Balanced output Connector Male XLR Pin 2 Hot Type Mic Line input RF ltered true bypass to balanced output Unbalanced output Connector Tip Sleeve Jack Impedance 22...

Page 20: ...remolo Rate range 0 85 to 2600 Hz Depth control 0 100 in posi ve range or out nega ve range of phase between clean and distorted signals Tube Gas Xenon Discharge voltage 5 5 kV System performance Freq...

Page 21: ...roved by Gamechanger Audio could void the User s authority to operate the equipment CA This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme...

Page 22: ...ntrol DEPTH 24 0 1023 CC 24 CC 56 Tremolo depth control INPUT GAIN 21 0 1023 CC 21 CC 53 Drive gain control VOLTAGE 22 0 1023 CC 22 CC 54 Voltage gain control BLEND 23 0 1023 CC 23 CC 55 Blend between...