background image

How to operate.

Installation & maintenance

PR

ODUC

T M

ANU

AL

RAIR-01 Version 6. Approved 23/02/2022

from the makers of

Summary of Contents for Clinell Rediair RAIR-UK

Page 1: ...How to operate Installation maintenance P R O D U C T M A N U A L RAIR 01 Version 6 Approved 23 02 2022 from the makers of ...

Page 2: ...PRODUCT CONTENTS Rediair decontamination device Pre filter Rediair decontamination device pre filter main combination filter HEPA 14 instruction manual Main combination filter HEPA 14 ...

Page 3: ...ty precautions 5 How to use Rediair Setup 6 LCD touch control panel 8 Disposal cleaning and maintenance External surface cleaning 11 Filter changing and cleaning 11 Cleaning a pre filter 12 Cleaning and changing times 12 How to change the pre filters 12 Disposal 14 How to change the main filters 15 Appendix Technical specifications 17 Declaration of Conformity 19 Contact 20 ...

Page 4: ...air quality indicator strip monitors a room s air quality and changes depending on the current air quality Rediair will change its internal fan speeds to account for the CADR required to decontaminate the surrounding air when in automatic mode Always read before commissioning Please carefully follow the instructions in the operating manual Non observance will invalidate the warranty GAMA Healthcar...

Page 5: ...n the filter is saturated the filter must be replaced GAMA Healthcare recommends replacement every six months In case of strong odour pollution a more frequent change is advisable 1 3 Highly efficient HEPA filter suspended matter filter The HEPA 14 filter filters airborne microorganisms smoke and dust particles down to 1μm in size at a rate of 99 995 or more In combination with stage 2 the HEPA 14...

Page 6: ...rator Consult instructions for use AU Regulatory Compliance Mark CE marked product European Conformity mark UK Conformity Assessed Do not dispose of in general waste Waste Electrical and Electronic Equipment WEEE Directive 2012 19 EU Article 11 2 Serial number Quantity Catalogue number Date of manufacture Maximum mass 20 9kg Electrical ratings Universal labels symbols and icons ...

Page 7: ...4 Maximum altitude Double insulated device Handle with care Keep dry Temperature limitation Atmospheric pressure limitation Humidity limitation ...

Page 8: ...omes wet discontinue use until dry and then test the device for proper operation before reuse Please speak to your local Rediair customer service representative for more information about the warnings and precautions NOTE To avoid electrical or fire hazards do not attempt to remove or replace the power cord The power cord and plug must be intact and undamaged check the cable s integrity before eac...

Page 9: ...n the two clips at the top of the filter and remove both sides Remove the main filters by pulling on the tabs both sides Remove the blue tape on the external covers of the device Before getting started and switching on the Rediair please remove all packaging The Rediair filters must be removed from their protective packaging 2 1 2 3 2 2 2 5 2 4 ...

Page 10: ...are facing outwards Remove the plastic wrap from the filters Connect the power supply Re install the pre filters both sides Re install the external covers both sides Note Ensure external covers are fitted correctly or the Rediair will not power on 2 9 2 7 2 10 2 8 2 6 ...

Page 11: ...to provide maximum decontamination turbo mode allows the Rediair fan to operate at its highest speeds 3 3 3 Night mode Rediair will operate at its quietest level All lights and displays are turned off and the fan runs at its slowest speed In sleep mode Rediair will not respond to the air quality sensor 3 4 Timer setting The Timer setting lets Rediair operate automatically for a select period rangi...

Page 12: ...ace the main filters If the filter indicator flashes red intermittently it is time to clean the pre filters 3 6 1 Working time display Press the filter indicator button to view working time of the current filters on the main display 3 6 As the Rediair display has only 3 digits values of 1000 hours or more will scroll across the screen For example below shows a working time of 2349 hours 3 6 2 Rese...

Page 13: ...10 LED AIR QUALITY INDICATOR Very good Not good Good Bad 3 7 ...

Page 14: ...d by the filter indicator button located on the digital display Pre filters should be cleaned regularly at least once a month When the filter indicator changes to red after 3000 hours approximately twice a year you should replace the main Rediair filter After replacing the Rediair main filter reset the filter DISPOSAL CLEANING AND MAINTENANCE WIPE IN AN S SHAPED PATTERN ENSURE CORRECT CONTACT TIME...

Page 15: ...h a HEPA filter if available The pre filter can also be rinsed with clean water but must be completely dry before being used again as any remaining moisture could potentially cause damage to the HEPA 14 filter Cleaning and changing times Pre filters are to be cleaned twice a month and replaced twice a year Main filters are to be replaced twice a year The ioniser is located within the device and ca...

Page 16: ...lters both sides Note Ensure external covers are fitted correctly or the Rediair will not power on µg m3 PM2 5 1h 2h 4h 8h 12h AUTO FILTER TIMER LOCK POWER MODE SPEED To clean Rediair s air outlet lift the grill from the side with the arrow symbol and clean the area with a dust cloth The pre filters can be rinsed with clean water The pre filters must be completely dry before being used again as an...

Page 17: ...cies Also if the device has been used in polluted air situations the filter must be packed into an airtight bag and disposed of per local waste guidance policies In the case of contamination with viruses please consult local guidance for the appropriate PPE Respiratory protection is recommended at a minimum of FFP2 Decommissioning Rediair has been designed to operate for many years However please ...

Page 18: ... dispose of them both sides µg m3 PM2 5 1h 2h 4h 8h 12h AUTO POWER MODE SPEED Switch off device and disconnect the power supply µg m3 PM2 5 1h 2h 4h 8h 12h AUTO FILTER TIMER LOCK POWER MODE SPEED FILTER TIMER LOCK When filter indicator 3 6 on control panel lights up continuously red it is time to change the pre filters and main filters 5 5 5 3 5 1 5 6 5 4 5 2 ...

Page 19: ...uch control panel Install the new pre filters both sides Re install the external covers both sides Note Ensure external covers are fitted correctly or the Rediair will not power on Connect the power supply Install the new main filters both sides making sure that the tabs are facing outwards Remove the plastic wrap from the filters 5 11 5 9 5 7 5 12 5 10 5 8 ...

Page 20: ...rbon HEPA filter FILTER CLASS HEPA ELECTRICAL CONNECTION V HZ 230 50 POWER W 85 NOISE LEVEL MIN DB A 3 M 22 NOISE LEVEL MAX DB A 3 M 66 CABLE LENGTH M 2 IP CLASS 20 LENGTH WIDTH HEIGHT MM 400 400 669 WEIGHT KG 15 1 ADDITIONAL FEATURES Intelligent particulate sensor child lock turbo mode programmable shutdown time ionisation function rounded edges brushless motors castor wheels APPENDIX The technic...

Page 21: ...ing agents may be used on external surfaces only CHEMICAL FLUID CONCENTRATION CLINELL UNIVERSAL WIPES N A CHLORINE 1000ppm HYDROGEN PEROXIDE WIPES 7 5 Use only the cleaning agents recommended Damage occurring through decontamination of the device using agents other than those cited in this document will void the warranty NOTE ...

Page 22: ...IEC 60335 2 65 EN 62233 IEC 62321 NAME OF COMPANY ADDRESS DISTRIBUTOR GAMA Healthcare Ltd The Maylands Building Maylands Avenue Hemel Hempstead Industrial Estate Hemel Hempstead HP2 7TG United Kingdom EUROPEAN REPRESENTATIVE GAMA Healthcare Ireland Ltd 13 Upper Baggot Street 2nd Floor Dublin 4 D04 W7K5 AUSTRALIAN SPONSOR GAMA Healthcare Australia Pty Suite 1 33 37 Duerdin Street Notting Hill VIC 3...

Page 23: ...han 60 countries Our Clinell Universal Wipes are the NHS number 1 most used disinfectant wipe trusted by 9 out of 10 NHS hospitals to help safeguard patients and healthcare workers from the risk of infection Rediair is part of the Redi family of products Redi products equip you to respond instantly to outbreaks infections and emergencies giving you the tools to protect your patients and staff They...

Page 24: ...d 23 02 2022 JBN220094 GAMA Healthcare Ltd The Maylands Building Maylands Avenue Hemel Hempstead Hertfordshire HP2 7TG UK Tel 44 0 20 7993 0030 E mail info gamahealthcare com from the makers of Scan QR code for more information ...