Dimensions
All Dimension in inch
33
11.4
10.2
5
19.6
6 inch
37.4
6.2
4.9
2.5
3
GHC 1000 2AM
Page 1: ...fl KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE CASSETTE FAN COIL TYPE ROOM AIR CONDITIONER TECHNICAL MANUAL...
Page 2: ...G DANGER Do not attempt to install this air conditioner by yourself Consult authorized service personnel for all installations Consult authorized service personnel for any repairs Do not attempt to re...
Page 3: ...port or indoor unit front panel A fan operates at high speed inside the unit and personal injury could result Be particularly careful regarding small children Do not start and stop air conditioner ope...
Page 4: ...ecautions to prevent infants from accidentally swallowing batteries A battery can be very harmful if swallowed If an infant accidentally swallows a battery make the infant eject it and consult your ph...
Page 5: ...precautions to prevent access by infants Unexpected accidents could occur Avoid to install the air conditioners near the fireplace and heating devices The shell of air conditioner may be warped when...
Page 6: ...ND FUNCTION OF PARTS 1 Air Filter Remove all dirt and dust from the air 2 Air flow direction Louvers Control airflow direction 3 Indicator Lamps Show the current operating status 4 Front Panel Air ent...
Page 7: ...NDICATOR GREEN Lights when unit is operating Flashes when unit turn on lasts for 20 seconds or 2 way 3 way stops 3 TIMER INDICATOR YELLOW Lights during TIMER operation Flashes when unit is broken down...
Page 8: ...connection tube coupler Cooling unit only For wiring access of outdoor unit Be sure to use the exclusive accessories list above in the installation otherwise it will lead to water leakage electric sho...
Page 9: ...clearance CAUTION The installation must be done by trained and qualified service personnel with reliability ac cording to this manual When lifting up and moving the units you must be guided by trained...
Page 10: ...nit and the mount ing template Fasten the mounting template on the unit with screws and tighten the corner of the drainage groove of the pipe outlet 3 Adjust the unit to proper installation position R...
Page 11: ...ipe must be installed In order not to twist the drainage hose there must be 1 1 5m be tween the pendant rack Use auxiliary drainage hose and clamp Insert drainage hose into the drain age plug then tig...
Page 12: ...ion check the status of water drainage while cooling After completing the installation check whether water drainage is fluent 2 Electrical wiring The parts material and electrical work supplied must m...
Page 13: ...nding terminals while connecting the indoor unit with the outdoor unit Panel installation 1 Position the stepping motor on the panel to the pipe end of the indoor unit as shown in figure 4 2 panel ins...
Page 14: ...adjust the height of the indoor unit through the hole on the corner of the panel No crack is permitted Figure 6 Improper screw tightening will re sult in malfunctions as shown in fig ure 5 After tigh...
Page 15: ...n in inch 23 3 23 3 12 5 11 25 6 23 3 25 6 8 8 4 7 6 2 16 5 1 inch 6 inch 2 7 inch 4 2 1 9 3 5 6 1 3 5 33 33 9 9 9 3 5 19 6 33 33 6 inch 37 4 6 2 4 9 37 4 2 5 3 GHC 300 2AM GHC 400 2AM GHC 500 2AM GHC...
Page 16: ...Dimensions All Dimension in inch 33 33 11 4 10 2 5 19 6 33 33 6 inch 37 4 6 2 4 9 37 4 2 5 3 GHC 1000 2AM...
Page 17: ...ic heater output Power Line plug Heat water valve output Cold water valve output Drainage pump output Neutra plug 4 DIP switch Float switch Indoor temperature sensor input Wired control receiver 3 DIP...
Page 18: ...Heating TEMP button and TEMP button Temperature adjustment range 16 32 FAN button Change the fan speed will change in turn as Low Medium High Auto SWING button 1 Press this button for the first time w...
Page 19: ...y screen displays all presetting parameters and remains constant after reaching presetting time air conditioner will automatically start as per presetting state After setting timing ON and OFF functio...
Page 20: ...r and another 1 auto matically after 1hour 2 After the setting of sleeping mode the heating operation enables the set temperature to drop 2 after 1 hour and another 2 auto matically after 1hour 3 The...
Page 21: ...o adjust the temperature setting with the range of 16 32 and increment of 1 4 Depress air speed button to select between Auto Low speed Middle speed High speed 5 Stop the air conditioner by depressing...
Page 22: ...ss the timing button again to set the function of Timer ON Depress other function buttons to set the operation condition after the starting of the air conditioner including mode temperature air damper...
Page 23: ...y one hour The thermostat setting can decrease total 2 J Operation Model 1 While in the cooling model whenever the SLEEP function is started the thermostat setting is automatically raised 1 J Setting...
Page 24: ...ded Periods One Month or More Operate the unit on fan mode for about one half day on a day with clear weather to assure that the internal parts are dried Clean the indoor unit by wiping with a cloth d...
Page 25: ...he Air Filter 1 Move the front panel 100 X to 120 X 2 Take the filter out 3 To install the air filter follow the opposite procedure of Removing If dirt is allowed to collect in the air fiter the airfl...
Page 26: ...ower outlet the protection circuit will operate for about 3 minutes preventing unit operation during that period During operation and immediately after stopping the unit the sound of water flowing in...
Page 27: ...set to the OFF position Is the timer operating Is the air filter dirty Are the air conditioner s intake grille or outlet port blocked Did you adjust the room temperature settings thermostat correctly...
Page 28: ...r plug from its outlet and connect it again then use the remote control unit to resume operation Auto Restant function is available after professional modification The air conditioner power has been i...