background image

 

Version 1, 23 June 2020, Page 

2

 of 

3

 

MOUNTING 

 

     IMPORTANT:

 

MUST BE FITTED TO A SOLID WALL OR OTHER FIRM SURFACE. 

For fixing to timber, use only hexagon coach screws. For fixing to brickwork, block work or cncrete, use the 
hexagon screws with 10mm wall plugs or equivalent. 

Grade 304 Stainless Steel M8 x 75mm hexagon coach screws and 10mm wall plugs supplied.

 

 

Accessible:

 Install as per AS 1428.1 Design for Access 

and Mobility. When in the horizontal position ensure 
seat does not present a hazard and the grab rail is 
accessible.

 

 

Positioning:

 In the horizontal position, level check and 

spot mark wall through seat frame mount holes. 

 

Fixing:

 For timber drill with pilot drill, for concret drill 

spot marks with 10mm bit. Plug and screw seat to wall 
using the 304 Stainless Steel M8 x 75mm hexagon 
coach screws supplied. 

 

Checking:

 Check seat is firmly secured to wall and 

Tension Grip Hinge screws are appropriate for ease of 
movement. 

 

     IMPORTANT: 

All measurements are subject to accepted manufacturing tolerances. To ensure accuracy please 

check actual product dimensions before drilling for installation. The manufacturer reserves the right to change 
specifications at any time without giving prior notification. This product should be installed by a qualified pluber. 
Local authority, and Building Regulations may apply to the installation of this product, and you should consult the 
appropriate bodies on these requirements. 

 

 