Gallien-Krueger Fusion 550 Owner'S Manual Download Page 6

Fusion 550 Bass Amplifier

Front Panel Features

Front Panel Features

1) Active/Passive Switch:

    Reduces the input signal 

from your bass by -10dB.  Choose Active for basses 

with active electronics and very high output. 

2) Input Jack:    

A standard ¼” input jack to plug 

in  active  or  passive  basses  using  an  instrument 

(shielded) cable.

3) Channel Select Switch:    

Allows you to store two 

different settings via the motorized knobs.  Switch 

to  Channel  1  and  adjust  your  settings  then  switch 

to Channel 2 and adjust the settings for your second 

channel.

4) Gain:

    Sets the preamp volume level before the 

shaping filters and EQ section.

  

5)  Frequency  Select  Switch:       

Sets  the  center 

frequency for the Contour control to either 500Hz 

or 800Hz.

6) Contour:

    Reshapes the voice of the amplifier 

by cutting mid frequencies at either 500Hz or 800Hz 

depending on the position of the Frequency Select 

Switch.

7) Bright:

    Boosts higher frequencies.  

8) Deep:

    Boosts lower frequencies.

9) Treble:

    Active shelving type control which boosts 

and cuts the high frequencies.

10) High Mid:

    Active bandpass type control which 

boosts and cuts at about 1kHz.. 

11) Low Mid:

    Active bandpass type control which 

boosts and cuts at about 250Hz.

 

12) Bass:

    Active shelving type control which boosts 

and cuts the low frequencies.

13) Horn Bi-Amp:

    Sets the ratio between the horn 

output and the master output.

14)  Master:    

Master volume control. 

15)  Power & LED:    

Power on/off switch and 

LED.  The LED ring is blue when the amplifier is 

on and flashes when the amplifier is muted via the 

Mute switch.  If there is an electrical fault (shorted 

output, over heat) the protection circuitry will be 

engaged muting the amplifier output and the LED 

ring will turn red.

16)  Mute:    

Mutes the master and DI output of the 

amplifier.  The Tuner output is not affected.  LED 

ring will flash blue when the amplifier is muted.

TREBLE

BRIGHT

DEEP

HIGH MID

LOW MID

BASS

CHANNEL

C H   2

O F F

PA S S I V E

ON

OFF

S H A P I N G

A C T I V E   E Q U A L I Z E R

CONTOUR

FREQUENCY

800 Hz

500 Hz

O N

O F F

O N

P O W E R

usion 550

Hybrid Valve Bass Amplifier

F

A C T I V E

I N P U T

C H   1

GAIN

O F F

M

U

T

E

HORN BI-AMP

MASTER

O N

O U T P U T

1        2       

3       

4       

5       

6       

7        8       

9       

10       

11       

12       

13       

14       

15       16       

Summary of Contents for Fusion 550

Page 1: ...Fusion 550 Owner s Manual ...

Page 2: ...ler or GK as soon as possible Gallien Krueger Inc 2234 Industrial Drive Stockton CA 95206 phone 209 234 7300 fax 209 234 8420 Internet www gallien krueger com Email info gallien com Always Listening I have never seen the point in doing things the way others have done them I also have not been very interested in following the latest fad I m a Stanford educated engineer who worked my way through sch...

Page 3: ...ING CAUTION ATTENTION TO PREVENT ELECTRIC SHOCK MATCH WIDE BLADE OF PLUG TO WIDE SLOT FULLY INSERTED POUR EVITER LES CHOCS ELECTRIQUES INRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRE SPONDANTE DE LA PRISE ET POUSSER JUSQU AU FOND CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO The lightning flash with arrow head s...

Page 4: ... Make certain that the AC outlet is properly grounded as well Do not use an adapter plug with this product Do Not Open the Amplifier Enclosure There are no user serviceable parts inside this product Opening the amplifier enclosure may present a shock hazard Modification to the product will void your warranty If liquid enters the unit or any metal object such as a paper clip accidentally falls insi...

Page 5: ...n Bi Amp compatible speaker cabinet set it to Bi Amp using the switch on the back of the cabinet See Page 8 for more details on GK s Horn Bi Amp System Initial Front Panel Control Settings Set all ac tive equalizer controls and contour to 12 o clock and the bright and deep switches off Set the Gain and Master Volumes to 0 Connect Your Bass Using an instrument shielded cable connect your bass to th...

Page 6: ...ich boosts and cuts the high frequencies 10 High Mid Active bandpass type control which boosts and cuts at about 1kHz 11 Low Mid Active bandpass type control which boosts and cuts at about 250Hz 12 Bass Active shelving type control which boosts and cuts the low frequencies 13 Horn Bi Amp Sets the ratio between the horn output and the master output 14 Master Master volume control 15 Power LED Power...

Page 7: ...n a different ground system 8 Balanced Direct Out A transformer balanced low impedance output to run directly to the PAsystem via a 3 pin XLR cable 9 Pre Post EQ Takes the Direct Out signal from before or after the EQ section 10 Direct Out Level Controls the output level of the Direct Out signal 11 Speakon Outputs High current twist lock Speakon output connectors Pins 1 and 1 send a fullrange sign...

Page 8: ...to Full range In this mode the cabinet s internal passive crossover is used to split the signal between the woofer and horn Use the Woofer Main knob on the front of the amplifier to control your output level The Horn knob is not used Note To avoid the risk of damage to the amplifier do not use a four conductor Speakon cable with non GK cabinets Instead use a two conductor Speakon or speaker cable ...

Page 9: ...BASS CHANNEL C H 2 O F F PA S S I V E CONTOUR FREQUENCY 800 Hz 500 Hz O N O F F O N A C T I V E C H 1 GAIN O F F M U T E HORN BI AMP MASTER O N 12 O clock 9 12 O clock 12 3 O clock 12 O clock 9 12 O clock Off Off 800Hz Off Off 12 3 O clock 9 O clock 9 12 O clock Off On 800Hz 12 O clock 9 O clock 12 O clock 12 3 O clock Sample Settings Your GK amplifier is versatile in its sound and tone Below are ...

Page 10: ...y in signal reproduction The treble is a shelving type control that boosts the high frequencies evenly Respectively the bass is a shelving control that evenly boosts the low frequencies The high mid and low mid are peak bandpass type controls with wide Q bandwidth patterns which are much more musical sounding Each of the four bands are connected in series meaning the output of the first band is fe...

Page 11: ...ntaining a safe temperature level Intelligent Protection Circuitry Gallien Krueger amplifiers use intelligent protection circuitry which constantly monitors for any un safe operating conditions such as short circuits or improperly wired speaker cables If an unsafe condi tion is detected the output signal is immediately mut ed and the power light changes from blue to red The amplifier will remain m...

Page 12: ...stant voltage crossover at 5kHz Noise 90dB A weighted Cooling Variable Speed Fan Protection Dimensions 5 25H x 19W x 10D Weight 27 5lbs Consumption 994W full 230W average Fuse 100V 120V T 10 A 220V 240V T 5 A Mains Voltage USA Canada 120 Volt 60Hz UK Australia 240 Volt 50Hz Europe 230 Volt 50Hz Japan 100 Volt 50Hz Korea 220 Volt 50Hz Mains Connect Standard IEC Receptacle Fullshortcircuit thermal R...