1  BEFORE STARTING THE INSTALLATION PROCEDURE

Carefully read this manual.
Installation and maintenance should be carried out by technical 
personnel qualified for this type of machine, in compliance with 
current safety regulations.
When receiving the unit please check its state verifying if any 
damage occurred during the transport.
For installation and use of possible accessories please refer to 
the pertinent technical sheets.
Identify the model of the ART-U fan coil following the indications 
on the packing container. See paragraph   Configurator  p. 19.

WARNING:

 Electrical and electronic products may not be 

mixed with unsorted household waste. Do NOT try to dis-
mantle the system yourself: the dismantling of the system, 
treatment of the refrigerant, of oil and of other parts must be 
done by an authorized installer and must comply with appli-
cable legislation. Units must be treated at a specialized treat-
ment facility for reuse, recycling and recovery. By ensuring 
this product is disposed of correctly, you will help to prevent 
potential negative consequences for the environment and 
human health. For more information, contact your installer 
or local authority.

2 INTENDED 

USE

Galletti S.p.A. will not accept any liability for damage or injury 
caused as a result of installation by non-qualified personnel; im-
proper use or use in conditions not allowed by the manufactur-
er; failure to perform the maintenance prescribed in this manual; 

use of spare parts other than original factory parts.
Equipment designed for ambient air conditioning and intended 
for use in civil comfort applications.

INSTALLATION SITE

When choosing an installation site, you should observe the fol-
lowing rules:

 

—  The air conditioning unit should not be placed immediately 

under a socket 

 

—  Do not install the unit in places where inflammable gases or 

powders are present

 

—  Do not expose the unit to sprays of water

 

—  Install the fan coil on walls able to withstand its weight. Keep 

a clear space all around the unit to assure the proper func-
tioning and accessibility for maintenance

 

—   Store the unit in its packing container until you are ready to 

install it to prevent dust from infiltrating inside it.

3 UNIT 

DESCRIPTION

Fan coil unit with Design cabinet, minimum depth and BLDC motor. See figure  p. 60 Exploded view .

DESIGN-DRIVEN INNOVATION

From the extensive experience of Galletti in the development 
and design of fan coil units, and in confirmation of its continu-
ous search for innovation, has been created ART-U, the result of 
a perfect combination of performance and design.
The ambitious goal of this project was to develop something 
absolutely new and unique, a product not yet present on the 
market, which on the one hand was able to meet the increasing-
ly stringent demands for energy efficiency, while on the other 
hand could, for the first time, reflect the latest trends in furnish-
ings and interior design.
With the new ART-U, Galletti this goal has been fully achieved, 
presenting on the market a new concept of hydronic indoor 
unit, a product that is characterized by its enviable technical 
performance and at the same time represents a true style shift 
in a field that has long been dominated by products that are all 
very similar to each other.
ART-U, with its width that in some places is only 10 cm, and 
thanks to its unique lines, was designed to be an absolutely 

all-purpose product, that adapts perfectly to rigorous and es-
sential environments as well as to warmer and more sophisticat-
ed spaces. Thanks also to the possibility of customizing the front 
panel, ART-U meets the demand for ever more personalization 
of the spaces to be furnished.
The achievement of extremely high aesthetic standards has not 
weakened the usual construction integrity of Galletti products: 
striving for innovation has in fact also focused on the compo-
nents and the use of new materials.
With ART-U the state of the art has been redefined also in terms 
of technical performance, thanks to the use of computational 
fluid dynamics simulations for the optimisation of the heat ex-
change inside the indoor unit combined with the use of perma-
nent magnet electric motors.

Summary of Contents for ART-U

Page 1: ...n innovative design and width up to only 10 cm Inverter controlled BLDC motor Low energy consumption Modulating operation 2 2 2 2 BLDC motor Tangential fan Supervision ERGO 2 pipes systems Vertical installation Design fan coil unit of small depth and BLDC motor FC66005296 09 18 ...

Page 2: ...aterials employing state of the art components and production technology The CE marking of the product ensures its compliance with the safety requirements of the following directives the Machinery Directive the Electromagnetic Compatibility Directive the Electrical Safety Directive and the Pressure Equipment Directive Fulfillment of the Ecodesign requirements is fully in keeping with the environ m...

Page 3: ...ERSIONS p 17 MAIN COMPONENTS p 18 CONFIGURATOR p 19 ACCESSORIES p 19 4 DIMENSIONS p 19 5 INSTALLATION p 20 INSTALLATION REQUIREMENTS p 20 MOUNTING BASE UNIT AND COVER CABINET p 21 6 CHECKS BEFORE STARTUP p 21 7 USE p 21 8 MAINTENANCE p 22 CLEANING THE AIR FILTER p 22 CLEANING THE HEAT EXCHANGER p 22 CLEANING THE CABINET p 22 9 TROUBLESHOOTING p 22 10 RATED TECHNICAL DATA p 23 ...

Page 4: ...ace all around the unit to assure the proper func tioning and accessibility for maintenance Store the unit in its packing container until you are ready to install it to prevent dust from infiltrating inside it 3 UNIT DESCRIPTION Fan coil unit with Design cabinet minimum depth and BLDC motor See figure p 60 Exploded view DESIGN DRIVEN INNOVATION From the extensive experience of Galletti in the deve...

Page 5: ... or dering the unit ART U It can be customized in different chromatic variations on request ART U Grey Front panel consisting of brushed natural aluminium sheets Side panels in ABS colour RAL 9005 Front grill supplied with black stainless steel filter Upper grille colour black consisting of adjustable fins in ano dized aluminium and ABS supports ART U White Front panel consisting of RAL9010 colour...

Page 6: ... board control the grill has two side doors to allow access to the control Front grille Stabilizes the operation of the tangential fan unit and is equipped with a stainless steel filter Electric motor Permanent magnet BLDC motor with inverter integrated in the ventilation unit An IP54 protection rating is guaranteed therefore dust inside is avoided and resistance to water spray is guaranteed Heat ...

Page 7: ... controller KBEVS EVO on board installation Kit for ART U MCLE Microprocessor control with display MY COMFORT LARGE MCSUE Humidity sensor for MY COMFORT LARGE EVO MCSWE Water sensor for MYCOMFORT EVO LED 503 controllers Electronic microprocessor control panels KBTES On board ART U installation kit suitable forTED controller TED 10 Electronic controller for BLDC fan equipped with inverter and ON OF...

Page 8: ...ewing the unit from the front Hydraulic connections on the opposite side are available on ly on order The water connection pipes must pass through the slots pro vided on the rear panel of the unit depending on the L or R version use the appropriate slot NOTE the electrical wiring must always be positioned on the opposite side of the plumbing connections Make the plumbing connections to the heat ex...

Page 9: ...ensure a correct intake of air and facilitate the filter removal See figure p 68 Air filter Once the installation of the base unit which also includes the hydraulic and electrical connections is completed it is possible to proceed with the assembly of the covering cabinet front pan el and side panels In order to fix the cabinet proceed with positioning it near the base unit so as to align the supp...

Page 10: ...in place 4 Once the filter has been repositioned fix it again with the two M5 screws WARNING THE FILTER MUST ALWAYS BE SECURED IN PLACE WITH THE SCREWS PROVIDED TO PREVENT ACCIDENTAL CONTACT WITH THE FAN It is recommended to replace the air filter once a year using an original replacement filter the indoor unit model is specified on the identification plate on the inside of the side panel CLEANING...

Page 11: ...Water pressure drop 1 E kPa 3 1 2 4 8 11 12 20 27 9 15 20 14 23 31 Heating capacity 3 E kW 0 73 0 93 1 05 1 28 1 7 2 14 1 98 2 41 2 94 2 65 3 22 3 92 3 08 3 74 4 56 FCCOP class E Water pressure drop 3 E kPa 1 1 2 4 8 11 12 20 27 9 15 20 14 23 31 Heating capacity 4 E kW 0 56 0 73 0 87 1 04 1 38 1 81 1 52 2 09 2 48 1 96 2 66 3 34 2 49 3 07 3 74 Water flow 4 l h 98 126 146 169 238 303 261 359 413 360 ...

Page 12: ......