background image

3E2362

 

Weigh

 

Scale

 

W310

 

v2

 

User

 

Manual

 

 

 

 

Page

 

7

 

 

Low

 

voltage

 

shutdown

 

When

 

the

 

battery

 

charge

 

drops

 

to

 

a

 

critical

 

level,

 

the

 

Weigh

 

Scale

 

will

 

shut

 

down.

  

At

 

this

 

stage

 

it

 

is

 

necessary

 

to

 

recharge

 

the

 

battery.

 

 

Summary of Contents for W310 v2

Page 1: ...Instructions WEIGH SCALE W310 v2...

Page 2: ...ry effort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or actions they...

Page 3: ...istics 20 Weight statistics 20 Deleting a weight from the statistics 21 Clearing the statistics 24 The weighing session 25 Weighing animals automatic or manual modes 25 Weighing static loads fine mode...

Page 4: ......

Page 5: ...for quality equipment that withstands tough agricultural conditions The Gallagher Weigh Scale range of weighing systems is simple tough innovative and reliable All of the Weigh Scales in the Gallaghe...

Page 6: ...r care and maintenance can extend its life Listed below are guidelines for keeping the Weigh Scale in good condition Don t submerge the Weigh Scale in any liquid Store the Weigh Scale in a cool dry pl...

Page 7: ...racket on a round post use the inner holes Don t mount the Weigh Scale bracket on the weighing crate or chute Installing the loadbars To install the loadbars follow these steps 1 Bolt the platform to...

Page 8: ...a table top or mounted on the Weigh Scale bracket supplied Position the Weigh Scale clear of the platform to ensure it does not interfere with the flow of animals during the weighing cycle within eas...

Page 9: ...y on its own will power the Weigh Scale continuously for a minimum of eight hours Charging the battery The battery in the Weigh Scale can be recharged using either a battery charger or an external 12...

Page 10: ...ys in the bottom left corner of the Weigh Scale s upper screen It is important to note that the battery icon will only ever show the actual amount of charge left in the battery when the Weigh Scale is...

Page 11: ...E2362 Weigh Scale W310 v2 User Manual Page 7 Low voltage shutdown When the battery charge drops to a critical level the Weigh Scale will shut down At this stage it is necessary to recharge the battery...

Page 12: ...wer of the two Weigh Scale screens The explanatory information will display only for a few seconds after it disappears the screen displays information relevant to the selected option This position tur...

Page 13: ...briefly appears Manual weighing is covered under Weighing static loads fine mode p 27 S This position accesses the setup options After the mode select switch is first turned to S the following informa...

Page 14: ...3 COMMUNICATIONS sets up a connection to a device plugged into the Weigh Scale s communications port 4 SELECT COUNTRY for a specific country sets a language country specific terminology and other opti...

Page 15: ...menu items are numbered from 1 to 4 Press the button to move to the previous setup menu item Press the button to move to the next setup menu item For example to move from 2 USER OPTIONS to 3 COMMUNICA...

Page 16: ...2 Depending on how the Weigh Scale was previously set up either the Drafting Off or the Two Way Drafting screen will display 3 Depending on the screen displayed do one of the following If the Draftin...

Page 17: ...ton 3 The current drafting limit will display on a screen that looks similar to that below 4 Press the button to enter the edit mode The screen will change to look like that below 5 Press the or butto...

Page 18: ...elow for more information on each of the User Options Press to save the displayed user options and return to the setup menu Weight units You can specify whether the Weigh Scale uses kilograms kg or po...

Page 19: ...Communications screen select 3 COMMUNICATIONS from the setup menu To change the port setting follow these steps 1 Press the button repeatedly until the required option is selected 2 Press to save the...

Page 20: ...y in which the Weigh Scale will be used Selecting a country changes the language and sets some country specific terminology and options To display the Select Country screen choose SELECT COUNTRY from...

Page 21: ...the battery charger or connect to a 12 volt battery If you are not connecting to an external power source the Weigh Scale s internal battery should be fully charged Refer to Charging the battery p 5...

Page 22: ...te for the weight of any accumulation of mud or dung left on the platform If it succeeds the Weigh Scale displays a zero icon If it does not you can manually restore zero by pressing the blue zero but...

Page 23: ...tatistics The displayed weight continues to reflect the actual weight on the platform In Fine mode automatic zero tracking is switched off This means the Weigh Scale does not automatically compensate...

Page 24: ...nformation similar to that shown below In the example above the drafting limit was set to 300 kg Six animals weighed below 300 kg These had an average weight of 292 kg and a total weight of 1753 kg Ei...

Page 25: ...erator presses the green button You can delete a captured weight from the statistics at two stages during a weighing session while the animal or static load is still supported by the platform or immed...

Page 26: ...before the next animal steps onto the platform you have an opportunity to delete from the statistics the weight just captured To delete the weight press the red delete button The last captured weight...

Page 27: ...before another load is placed on the platform you have an opportunity to delete from the statistics the weight just captured To delete the weight press the red delete button The last captured weight...

Page 28: ...eps 1 Set the mode select switch to the Automatic Manual or Fine weighing mode 2 Press the button After you press the button all values will be set to zero and the lower screen will display as shown i...

Page 29: ...blue Zero button 4 Load the animal onto the platform Ensure the animal is entirely supported by the platform no hooves on the ground and that no object is restraining or resting on the animal 5 The W...

Page 30: ...weight replaces the original weight and the statistics are updated 8 Record the weight 9 Move the animal off the platform After the animal has left the platform the following events occur The red lig...

Page 31: ...ain The new weight replaces the original weight and the statistics are updated Weight on scale memory The Weigh Scale remembers the weight on the display at the time it is switched off This weight is...

Page 32: ...the weighing mode Automatic and Manual modes In the Automatic and Manual weighing modes zero tracking is automatically implemented if after the animal leaves the weighing platform the residual weight...

Page 33: ...printer with the Weigh Scale W310 v2 scale Printing weights during a weighing session To print each weight during a weighing session follow these steps 1 Connect the printer cable to the port on the W...

Page 34: ...Scale 2 Turn the mode select switch to S to display the setup menu 3 Select 3 COMMUNICATIONS 4 Ensure the port is set to Printer 5 Press to return to the setup menu 6 Select the required weighing mod...

Page 35: ...ed top mounting holes fit all sizes of platforms and crushes 6m 20 long tough loadbar cables fitted with high quality connectors Fully waterproof No rubber mounts Talk to your Gallagher dealer about t...

Page 36: ...ase of bolting down 6 m 20 long tough loadbar cables fitted with high quality connectors Fully waterproof No rubber mounts High capacity load cells withstand large shock loads Heavy steel chassis cons...

Page 37: ...ct sturdy design No rubber to delaminate or rot Spiral spring metal reinforced cable High quality moisture proof connectors Gallagher Suspension Load Cell 500 kg Features 500 kg capacity loadcells Rep...

Page 38: ...mensions Metric Imperial Length 232 mm 9 25 Width 212 mm 8 5 Height 90 mm 3 5 Weight 2 kg 4 4 lb General Operating Temperature 20 to 50 C 5 to 120 F Accuracy 1 Environmental Protection Rating IP65 Inp...

Page 39: ...Duty Loadbars 4500 kg Automatic or Manual modes 0 49 9 kg 200 g increments 500 g increments 50 199 9 kg 500 g increments 500 g increments 200 499 9 kg 1 kg increments 1 kg increments 500 1999 9 kg 2...

Page 40: ...o a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help conserve...

Reviews: