Gallagher SMB T11 Installation Notes Download Page 3

Building cable

Facia

Reader tail

Connection

Fit screw to secure facia to bezel

Bezel

Building cable

No. 6 pan head screw

No. 6 pan head screw

Installation

The reader is designed to be mounted on any solid flat surface. However, installation on metal 
surfaces, particularly those with a large surface area will reduce read range. The extent to 
which the range is reduced will depend upon the type of metal surface.

The recommended mounting height for the reader is 1.1 m (3.6 ft) from the floor level to the 
centre of the reader. However this may vary in some countries and you should check local 
regulations for variations to this height. If using conduit, the reader can be mounted on a 
mounting block (C300951).

ATTENTION: This equipment contains components that can be damaged by electrostatic 
discharge. Ensure both you and the equipment are earthed before beginning any servicing.