English
Gallagher 3E4449 M950 M1400 Energizer User Manual
7
INSTALLATION GUIDE
Step 1. Install the Energizer
Mount the energizer on a wall, under cover and
out of reach of children. Install where there is no
risk of the energizer incurring
fi
re or mechanical
damage and if possible away from heavy electrical
equipment eg. pumps or other items that may
cause electrical interference.
a)
Using the template on the back page, drill 2 x
4mm (5/32”) holes (A & B).
b)
Fix the screws provided into the wall leaving the head of
the screw about 3mm (1/8”) out from the wall.
c)
Place the energizer over and slide down onto the
moun ng screws.
Step 2. Install the Earth system
Buildings and gates for example, can become electri
fi
ed with
fence voltages if the energizer is improperly earthed.
Follow earthing instruc ons carefully
.
a)
Install at least 3 x 2m (6 ) galvanised earth stakes into damp soil where
possible. In dry condi ons or in low mineral content soil more earth stakes
may be required. Earth stakes must be at least 3m (10 ) apart and at least
10m (33 ) away from any mains cabling, telephone cabling, water pipes or
building earth. Do not connect the earth terminal to any building metal work
or framing.
b) To
a ach the earth cable:
1.
Using Underground Cable (G627) remove 5cm (2”) of plas c coa ng from
one end of the cable wire and connect to the green (
) terminal on the
energizer.
2. A ach the cable to the earth system by removing 10cm (4”) of insula on
from the cable at each Earth Stake (G879) and then clamp the exposed
wire to each stake using an Earth Clamp (G876).
3.
Tighten the clamp.
For further instruc ons on the earth (ground) system see the Gallagher Power
Fence™ Manual.
Note:
Poor grounding can cause interference on telephone lines, radios and
televisions. This can be recognised by a clicking sound on telephones.