9
English
Gallagher 3E0679 M600 M700 M1200 User Manual
Step 2. Connect to earth (ground) system
a)
Using Underground Cable (G627) remove 5cm (2”) of plas c coa ng from one
end of the cable and connect to the green ( ) terminal on the energizer.
b)
A ach the cable to the earth system by removing 10cm (4”) of insula on from
the cable at each Earth Stake (G879), then clamp the exposed wire to each
stake using an Earth Clamp (G876).
c)
Tighten the clamp.
Reference Earth:
An addi onal earth stake is required to allow correct measurement of the earth
voltage.
a)
Install a single stake (G878/ G879) at least 60cm (2 ) long, at least 10m (16 )
from the main Energizer earth system and at least 10m (33 ) from any power
supply earth peg, underground telephone or power cable.
b)
Using Underground Cable (G627) connect the Reference Earth Stake to the
black ( ) terminal on the Energizer.
Important:
If the Reference Earth is not connected, the Earth Voltage display will
fl
ash 0.0. Note that if your earth is near perfect, the display may also
fl
ash 0.0. To
con
fi
rm that your earth system is good check the voltage at the stakes is 0.0.
Step 3. Connect the fence - Full Power
a)
Connect Energizer’s red Output ( ) terminal to the fence using Underground
Cable (G627).
b) A ach the other end of the cable to the fence using a Joint Clamp (G603).
Important:
If you wish to use the Output Voltage informa on see the sec on
“Understanding your Energizer: Output Voltage and Alarm” (p.14)
9
kV
kV
M1200
RED
GREEN
BLACK
To Fence
To Earth System
To Reference Earth
YELLOW
To Fence