IMPORTANT INFORMATION

WARNING: Read all instruc  ons.

Save these instruc  ons.

•     WARNING -

 Do not connect to mains adaptors or 

mains-operated equipment. 

If using a 12V rechargeable ba  ery, 

disconnect the ba  ery from energizer before charging.

• This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabili  es, 
or lack of experience and knowledge, unless they have been 
given supervision or instruc  on concerning use of the appliance 
by a person responsible for their safety.

• Young children should be supervised to ensure that they do not 

play with the appliance.

• Regularly inspect the supply cord, cables, wires and energizer for 

any damage. If found damaged in any way, immediately cease 
use of the energizer and return it to a Gallagher Authorised 
Service Centre for repair in order to avoid a hazard.

•  It is recommended that, in all areas where there is a likely presence of unsupervised children who will be unaware of 

the dangers of electric fencing, that a suitably rated current limi  ng device having a resistance of not less than 500 
ohms be connected between the energizer and the electric fence in this area.

•  The appliance is not intended for use by young children or infi rm persons without supervision.

•  Do not use the energizer with non-rechargeable ba  eries.

•  Do not mount in places exposed to heat sources (e.g. a sun heated metal wall).
•  Refer servicing and replacement ba  eries to a Gallagher Authorised Service Centre.

•  Check your local council for specifi c regula  ons.

•  Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.

•  Well maintained electric fences kept clear of vegeta  on with high quality insula  on are extremely unlikely to cause 

fi res. In   mes of extreme fi re risk, disconnect energizer.

•  Electric animal fences shall be installed and operated so that they cause no electrical hazard to persons, animals or 

their surroundings.

•  Do NOT become entangled in the fence. Avoid electric fence construc  ons that are likely to lead to the 

entanglement of animals or persons.

• WARNING - INSTALLERS/USERS SHOULD NOTE: 

Avoid contac  ng 

the fence with the head, mouth, neck or torso. Do not climb over, 
through or under a mul  -wire electric fence. Use a gate or a specially 
designed crossing point.

•  An electric animal fence shall not be supplied from two separate energizers or from independent fence circuits of 

the same energizer.

•  For any two separate electric animal fences, each supplied from a separate energizer independently   med, the 

distance between the wires of the two electric animal fences shall be at least 2.5m. If this gap is to be closed, this 
shall be eff ected by means of electrically non-conduc  ve material or an isolated metal barrier.

Summary of Contents for BA20

Page 1: ...R BA20BA30 BA40BA80 9 12V Instructions Installatie instucties Notice d installation Betriebsanleitung Monteringsvejledning Instrucciones Monteringsinstrucktioner Istruzioni per l installazione ENG NED FRA DEU DAN ESP SVE ITA ...

Page 2: ...E5023 Edi on 2 September 2019 DISCLAIMER Whilst every effort has been made to ensure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or ac ons they may make as a result of using this informa on In accordance with the Gallagher policy of con nuing development design and specifica ons are subject to ...

Page 3: ... de vie de la Ba erie 19 Déchets d équipements électriques et électroniques 20 Spécifica ons du produit 21 Deutsch 22 Wich ge Informa onen 22 Installa onsanleitung 25 Ba erie Lebensdauer 26 Elektrische und elektronische Abfallprodukte 27 Produkt Spezifizierungen 28 Dansk 29 Vig g Informa on 29 Installa onsvejledning 31 Ba erileve d 32 Affald af elektrisk og elektronisk udstyr 33 Produktspecifika oner ...

Page 4: ...44 Ba eriets livslängd 45 Avfall elektrisk och elektronisk utrustning 46 Produktspecifika oner 46 Italiano 47 Informazioni Importan 47 Guida all installazione 50 Durata della ba eria 51 Ro amazione a rezzature Ele riche od Ele roniche 52 Specifiche tecniche 53 ...

Page 5: ...ns without supervision Do not use the energizer with non rechargeable ba eries Do not mount in places exposed to heat sources e g a sun heated metal wall Refer servicing and replacement ba eries to a Gallagher Authorised Service Centre Check your local council for specific regula ons Fence wiring should be installed well away from any telephone or telegraph line or radio aerial Well maintained elec...

Page 6: ...V 15 m for power lines opera ng at a nominal voltage exceeding 1 000 V Electric animal fences intended for deterring birds household pet containment or training animals such as cows need only be supplied from low output energizers to obtain sa sfactory and safe performance In electric animal fences intended for deterring birds from roos ng on buildings no electric fence wire shall be connected to ...

Page 7: ...ads Red Black Ba ery Red Black WARNING Remove internal ba ery before connec ng the 12V SLA external ba ery Note 12V ba ery lead set Op onal accessory G596003 1 Connect the battery For 9V alkaline ba ery For 12V SLA rechargeable ba ery 2 Connect leads a Connect the Green earth lead to the earth stake b Connect the Red fence lead to the Reel or fence wire For 9V alkaline ba ery For 12V SLA rechargea...

Page 8: ...Normal Mode Manages the performance to give extended ba ery life Switch BA20 BA30 Switch BA40 BA80 3 Switch energizer on The indicator light flashes green with each fence pulse No flashing indicates that the ba ery is flat or the unit is switched off 1 Energizer 2 Earth stake 3 Reel 4 Polywire Turbo Wire 5 Treadin Post 6 Insul grip 7 Pigtail post 8 Earth Green 9 Live Red Portable fence ...

Page 9: ...ates that the ba ery needs replacing 9V BA40 BA80 A red flashing LED indicates the ba ery voltage is low and the ba ery needs replacing 9V Note There is no low ba ery indica on when using a 12 V ba ery Important Ba ery Informa on Use 9V Alkaline or 12V SLA ba eries only Do not recharge alkaline ba eries Ensure correct polarity of connec ons if using a 12V SLA ba ery Remove the ba ery if the energiz...

Page 10: ... 12V Sealed Lead Acid SLA requires adapter G596003 Average Current draw 24 mA 34 mA 43mA 90mA Peak Current draw 39 mA 61 mA 50 mA 100 mA Output Voltage no load 9 6 kV 9 6 kV 9 6 kV 9 6 kV Stored Energy 0 17 J 0 25 J 0 4 J 0 8 J Output Energy maximum 0 12 J 0 19 J 0 28 J 0 56 J Dimensions HxWxD 295mm x 160mm x 280 mm Weight 1 6 kg IP Ra ng IPX4 ...