Galiso LDD-4 Installation/Operation Instruction Manual Download Page 9

 

Section 5 

– 2 

21-11-1027 

7.1 SPARE PARTS 

– 220 Volt

 

 

The LDD-4 has been designed with modular components for ease of replacing parts 
if necessary. See Figure 2 or 3 (dependent on the voltage of your machine and code 
requirements), Replacement Components: 

 

Electrical

Enclosure

Assembly

Heater

Tube

Assembly

220 Volt

Components

25-41-3196
(US coded)

A.

C.

European Standard

B. 25-41-3197

 (CE coded)

Blower /

Filter

Assembly

D.

25-41-3188

25-41-3025

OR

Fuse 15 Amps

250V, 1-1/4” x 1/4”

88-11-0053

E.

 

Figure 3, Spare Parts -220V 

 

 
 

Item 

Part No. 

Description 

A. 

25-41-3196 

Electrical Enclosure Assembly US Coded 

B. 

25-41-3197 

Electrical Enclosure Assembly CE Coded 

C. 

25-43-3025 

Heater Tube Assembly 

D. 

25-41-3188 

Blower / Filter Assembly 

E. 

88-11-0053 

Fuse, 15 Amp, 250V, 1-

1/4” x ¼” 

Summary of Contents for LDD-4

Page 1: ...ALISO LIGHT DUTY DRYER INSTALLATION OPERATION INSTRUCTION MANUAL MANUAL NUMBER 21 11 1027 Issued July 2018 Copyright 2018 Galiso Inc 22 Ponderosa Ct Montrose CO 81401 970 249 0233 800 854 3789 www gal...

Page 2: ...DANGER DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS AND DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS...

Page 3: ...nstallation 3 1 5 0 Operation 4 1 6 0 Maintenance 4 1 7 0 Spare Parts 110Volt 5 1 7 1 Spare Parts 220Volt 5 2 List of Tables and Figures Number Title Page Figure 1 LDD 4 Galiso Cylinder Dryer 2 1 Figu...

Page 4: ...and can produce temperatures up to 175 F to accelerate the drying of steel and aluminum cylinders Cool can be selected to use non heated air for protection of fiber wrapped or composite cylinders The...

Page 5: ...Switch Heat Cool Off Dryer Probes x 4 Figure 1 LDD 4 Galiso Light Duty Dryer Power Requirements 110 Volt single phase 50 60Hz 20 Amp 220 Volt single phase 50 60 Hz 12 Amp Blower Motor generates 95 CF...

Page 6: ...rable heat Use insulating gloves to protect hands against possible burns from hot areas and items D Do not cover motor fan cowl Do not drop screwdrivers nails etc into the openings of the fan cowl E M...

Page 7: ...position E After cylinders have been drying for a short time 5 10 minutes check each cylinder for dryness and replace on the dryer if necessary or load the next cylinder NOTE Cylinder dry times can v...

Page 8: ...your machine Replacement Components Electrical Enclosure Assembly Fuse 20 Amps Blower Filter Assembly Heater Tube Assembly 110 Volt Components 25 41 3191 88 11 0054 A D C B 25 41 3186 25 43 3024 Figu...

Page 9: ...sembly Heater Tube Assembly 220 Volt Components 25 41 3196 US coded A C European Standard B 25 41 3197 CE coded Blower Filter Assembly D 25 41 3188 25 41 3025 OR Fuse 15 Amps 250V 1 1 4 x 1 4 88 11 00...

Page 10: ...equipment malfunction notify Galiso 1 800 854 3789 and provide the Model Name Model Number Serial Number and a description of the problem Return Authorization Number shipping and or service informati...