5.0 OPERATION

 

 

A.  Galiso, Inc. recommends a warm up time of approximately 2 minutes at the start-

up of the machine. Switch the Power Switch to the HEAT position. After the warm 
up, the Power Switch can remain in the HEAT position, or be switched to COOL 
or OFF 

 

B.  Check that the cylinders are emptied and drained of water. 

 

C.  Invert drained cylinder and place upside down with a manifold outlet inserted into 

the cylinder neck. 

 

! CAUTION ! 

Avoid bending or otherwise damaging the tube. 

 

D.  When cylinders have been loaded, flip the Power Switch to the HEAT or COOL 

position. 

 

E.  After  cylinders  have  been  drying  for  a  short  time  (5-10  minutes),  check  each 

cylinder  for  dryness,  and  replace  on  the  dryer  if  necessary  or,  load  the  next 
cylinder. 

 

NOTE:

 Cylinder dry times can vary, depending on the size and/or material. 

Galiso, Inc. recommends using the COOL setting for composite cylinders.  

 

! CAUTION ! 

The dryer can remain “On” when changing out cylinders but 
the operator should be careful to avoid touching the Manifold 
Frame, as it may be hot. 

 

F. 

To  shut  down  at  the  end  of  the  day,  flip  the  Power  Switch  to  “COOL”  for 
approximately  2  minutes  for  the  unit  to  cool  down  before  flipping  to  the  “OFF” 
position. 
 

6.0 MAINTENANCE

 

 

A.  No regular maintenance is required except to check the air filter on top of the 

muffler at least once a month and replace if needed. 

 

 
 

 

Summary of Contents for LDD-4

Page 1: ...ALISO LIGHT DUTY DRYER INSTALLATION OPERATION INSTRUCTION MANUAL MANUAL NUMBER 21 11 1027 Issued July 2018 Copyright 2018 Galiso Inc 22 Ponderosa Ct Montrose CO 81401 970 249 0233 800 854 3789 www gal...

Page 2: ...DANGER DO NOT USE THIS EQUIPMENT TO PURGE TOXIC OR FLAMMABLE GAS AND DO NOT USE THIS EQUIPMENT UNDER FLAMMABLE VOLATILE OR TOXIC ENVIRONMENTAL CONDITIONS...

Page 3: ...nstallation 3 1 5 0 Operation 4 1 6 0 Maintenance 4 1 7 0 Spare Parts 110Volt 5 1 7 1 Spare Parts 220Volt 5 2 List of Tables and Figures Number Title Page Figure 1 LDD 4 Galiso Cylinder Dryer 2 1 Figu...

Page 4: ...and can produce temperatures up to 175 F to accelerate the drying of steel and aluminum cylinders Cool can be selected to use non heated air for protection of fiber wrapped or composite cylinders The...

Page 5: ...Switch Heat Cool Off Dryer Probes x 4 Figure 1 LDD 4 Galiso Light Duty Dryer Power Requirements 110 Volt single phase 50 60Hz 20 Amp 220 Volt single phase 50 60 Hz 12 Amp Blower Motor generates 95 CF...

Page 6: ...rable heat Use insulating gloves to protect hands against possible burns from hot areas and items D Do not cover motor fan cowl Do not drop screwdrivers nails etc into the openings of the fan cowl E M...

Page 7: ...position E After cylinders have been drying for a short time 5 10 minutes check each cylinder for dryness and replace on the dryer if necessary or load the next cylinder NOTE Cylinder dry times can v...

Page 8: ...your machine Replacement Components Electrical Enclosure Assembly Fuse 20 Amps Blower Filter Assembly Heater Tube Assembly 110 Volt Components 25 41 3191 88 11 0054 A D C B 25 41 3186 25 43 3024 Figu...

Page 9: ...sembly Heater Tube Assembly 220 Volt Components 25 41 3196 US coded A C European Standard B 25 41 3197 CE coded Blower Filter Assembly D 25 41 3188 25 41 3025 OR Fuse 15 Amps 250V 1 1 4 x 1 4 88 11 00...

Page 10: ...equipment malfunction notify Galiso 1 800 854 3789 and provide the Model Name Model Number Serial Number and a description of the problem Return Authorization Number shipping and or service informati...

Reviews: