Configuring the Amplifier Enable Circuit
ICM-42000 and ICM-42100
The following section details the steps needed to change the amplifier enable configuration for the DMC-40x0
controller with an ICM-42000 or ICM-42100. For detailed instruction on changing the amplifier enable
configuration on a DMC-40x0 with an ICM-42200 see the section in Chapter 3 labeled ICM-42200 Amplifier
Enable Configuration. For electrical details about the amplifier enable circuit, see the ICM-42000 and ICM-42100
Amplifier Enable Circuit section in Chapter 3.
For DMC-4080 refer to DMC-4080 (Steps 1 and 2) section below.
NOTE:
From the default configuration, the configuration for +12V High Amp Enable Sinking Configuration does
not require the remove of the metal cover. This can be achieved by simply changing the jumpers.
DMC-4040 (Steps 1 and 2)
Step 1: Remove Cover
Notes:
1.
Cover Removal:
A.
Remove Jack Screws (20 Places)
B.
Remove #6-32x3/16” Button Head Cover Screws (4 Places)
2.
Lift Cover Straight Up and Away from Unit.
DMC-40x0 User Manual
Appendices
•
210
Summary of Contents for DMC-4040
Page 54: ...Chapter 3 Connecting Hardware 45 DMC 40x0 User Manual...
Page 55: ...DMC 40x0 User Manual Chapter 3 Connecting Hardware 46...
Page 56: ...Chapter 3 Connecting Hardware 47 DMC 40x0 User Manual...
Page 73: ...Figure 4 1 GalilTools DMC 40x0 User Manual Chapter 4 Software Tools and Communication 64...
Page 185: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 7 Application Programming 176...
Page 205: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 10 Theory of Operation 196...
Page 222: ...Step 2 Remove ICM s Appendices 213 DMC 40x0 User Manual...
Page 232: ...DMC 4080 Steps 4 and 5 Step 4 Replace ICM s Appendices 223 DMC 40x0 User Manual...