Encoder 15 pin HD D-Sub Connector (Female)
Pin #
Label
Description
1
MI+
I+ Index Pulse Input
2
MB+
B+ Main Encoder Input
3
MA+
A+ Main Encoder Input
4
AB+
B+ Aux Encoder Input
5
GND
Digital Ground
6
MI-
I- Index Pulse Input
7
MB-
B- Main Encoder Input
8
MA-
A- Main Encoder Input
9
AA-
A- Aux Encoder Input
10
HALA
A Channel Hall Sensor
11
AA+
A+ Aux Encoder Input
12
AB-
B- Aux Encoder Input
13
HALB
B Channel Hall Sensor
14
HALC
C Channel Hall Sensor
15
+5V
+5V
DB-9 Male Serial Connector (Serial Port)
Pin #
Signal Direction
Signal Name
Signal Function
1
-
-
-
2
Output
TxD
Transmit Data
3
Input
RxD
Receive Data
4
-
-
-
5
-
GND
Ground
6
-
-
-
7
Output
CTS
Clear To Send
8
Input
RTS
Request To Send
9
-
-
-
Jumper Description for DMC-30000
Label
Function (If jumpered)
OPT
Reserved
MO
When controller is powered on or reset, Amplifier Enable lines will be in a Motor Off state.
A SH will be required to re-enable the motors.
19.2
Baud Rate setting – see
table below
UG
Used to upgrade controller firmware when resident firmware is corrupt.
MR
Master Reset enable. Returns controller to factory default settings and erases FLASH.
Requires power-on or RESET to be activated.
Baud Rate Jumper Settings
19.2
BAUD RATE
ON
19200
OFF
115200 (Recommended)
Chapter 5 Integrated Components▫ 25
DMC-3x01x UL Installation Manual