Gal Pro
Instruction 1.0
Valves - Water & Fert.
Turn the selector to Valves - Water & Fert. Menu
In this menu enter the water and fertilizer amounts and the valve
constants.
Subject
Example
Explanation
Valve number
1
Change the valve number via the Next and Prev keys
Valve Setup
Automatic
Use the "+" and "-" keys to set the automat status for each
active valve.
Cancel - A cancelled valve will not irrigate even though it is
programmed in a sequence.
N. Activ -Undefined valve.
Please note !! When entering
data for the first time:
First define the water counter number, the water and fertilizer
unit before programming the water required.
Water Req.
30 M3
The amount of water for the irrigation cycle.
Frt.Req.
2 L/M3
The amount of fertilizer required according to the unit set in
the Fert. Unit.
Wtr.Befor.
5 M3
The amount of water before starting the fertilization.
Wtr.After
1 M3
The amount of water after fertilization.
Water Count.No.
1
The water counter that counts the water for the valve.
Water Units
M3
Via the "+" and "-" keys select one of the options: M3,
Seconds, Minutes, Hours, Liter.
6. Programming
Fertilizer
Water
Irrigation End
Water After
Fertilization. Segment
Water Before
Irrigation Start
Services
System Setup
Sequence Setup
Filter Flush
Fertilization
Sequence Timing
Valve • Water & Fert.
Water
Counter
Diaries
Alarms
Valve Info
Sequence Info
Manual Overriding
Sequence Status
Valve Status
System Status