18. Make sure that no unintended firing situations can occur. Common 
causes can be through strong electrical, magnetic, and 
electromagnetic fields as well as other voltage sources. 
 
19. An often underestimated risk, are unintended firings due to live 
contacts found on equipment such as mobile phones, two way radios, 
as well as rechargeable battery driven portable power tools. Even 
when due care and attention is taken, a battery pack or similar can 
be a hazard when dropped, especially as live contacts are revealed. 
 
20. Unintended firing can be caused by thunderstorms or the 
electrostatic fields built up during the approach of a thunderstorm. 
We recommend evacuating and securing the pyrotechnics area in this 
situation. 
 
21. Another possible danger for unintended firings is potential 
equalization currents. Be aware that these currents may occur 
between conductive building segments themselves, or between these 
conductive segments and earth potential. Neither e-matches nor 
wiring should come into contact with such segments. 
 
22. Please be aware that through your pyrotechnical effects ionized 
gases are created. These ions increase the conductivity within the 
air. This ionization process can cause an electrical arcing 
especially within the vicinity of high voltage overhead cables. This 
may lead to lethal consequences for pyrotechnicians and other 
persons. Please also note that wind conditions can be totally 
different a few metres above the ground. 
 
23. Ensure that the firing of pyrotechnic effects can only be 
undertaken by the authorized pyrotechnician. Keep the firing system 
under lock and key when not in use, and ensure it is never left 
unattended during use, with the key in it! Within our safety 
concept, all firing systems are set with individual codes, which 
inhibit unintended and accidental firing through third parties. If 
requested we can also supply systems with the same coding. This may 
be necessary if within a company more than one transmitter is used 
or when companies exchange the units between each other. 
 
24. By using the key code numbers 901 and 311, we are using a 
standard key code, which can also be found in other products. Upon 
customer request we are able to supply other key codes. 
 
25. Please ensure that the relevant safety distances are met by 
everybody. The safety margins are to be kept in place from the 
beginning of the event until such time as the pyrotechnician 
releases the area after firing, and removal of unfired products and 
effects. 
 
26. At all times first connect the e-match to a 100% non-live firing 
line, which is not connected to a firing unit. A pyrotechnic effect 
is classed as 'armed' from the time the e-match wires are connected 
to a firing unit. This is irrespective if the firing unit is 
switched on or off! 
 
27. In the interest of your own safety, and the protection of the 
devices always use a sufficient length of firing wire. 

Summary of Contents for PYROTEC PFS Pocket

Page 1: ...1 User Manual Galaxis Showtechnik PYROTEC PFS Pocket Firmware 1 3 Revision Date February 7th 2019 Batch No EUSP100101 USSP100101...

Page 2: ...essing the submenu Special functions 12 12 2 Acoustic Signals 12 12 3 Transmitting System ID and Teaching in devices 12 12 4 Setting the radio channel Frequency manually 12 12 5 PFS Pocket teach in an...

Page 3: ...damage unit aging as well as the wear and tear of the unit This fundamental thesis was the basic principle when writing these instructions 1 Smoking or naked flames are strictly prohibited within the...

Page 4: ...ing the rental period of the units Advise your staff that it is very important to report any possible damage of the units immediately Customers that have borrowed or rented the equipment are hereby in...

Page 5: ...ians and other persons Please also note that wind conditions can be totally different a few metres above the ground 23 Ensure that the firing of pyrotechnic effects can only be undertaken by the autho...

Page 6: ...9 Make sure the devices are switched off before connecting the e matches 30 When stripping the cable insulation of the igniters and connecting them you must ensure that they are not stripped so far ba...

Page 7: ...eryone in your company who will work with the equipment must receive information instruction training and supervision with regards to the safe use of the equipment The most current version of the safe...

Page 8: ...8...

Page 9: ...inated 7 Button and LED Arm Button to activate and deactivate the firing mode If the firing mode is activated the LED is illuminated 8 Battery Cover The batteries are located in this compartment under...

Page 10: ...en illuminated constantly in blue to indicate that the unit is on After switching on the device will be in normal mode The firing mode is switched off The PFS Pocket can only be switched off when the...

Page 11: ...wlessly 10 Switching on and off the deadman function Deadman means that this button DM must be held depressed at the same time as the firing channel button is depressed in order to transmit an ignitio...

Page 12: ...adio channel is set to 0 and the button 2 indicates the decade while the 3 indicates the unit position When for example the button 2 is pressed four times and the button 3 seven times so radio channel...

Page 13: ...values form For example Forming radio channel 383 from 283 by pressing the arrow button Hundreds 1 is not allowed Select a value from 0 to 5 in the tens before selecting the value 3 in the hundreds A...

Page 14: ...hen the two lower LEDs light up briefly for the second digit of the version number This is 0011 binary and this corresponds to 3 decimal The version number 1 3 results from the values 1 and 3 13 Radio...

Page 15: ...tated above had happened we are only liable if the defect was due to faulty workmanship or component parts The devices have been developed manufactured and tested to the best of our knowledge and beli...

Page 16: ...D V9X LMD400R Maximum radio frequency power transmitted 10 mW Channel Spacing 12 5 kHz Number of radio channels 360 458 0000 462 5000 MHz Modulation FM narrow band Frequency Shift 3 kHz Receiver Princ...

Page 17: ...nd contact details for requesting an EU declaration of conformity Galaxis Showtechnik GmbH Lohgerberstr 2 84524 Neu tting Germany Tel 49 8671 73411 Fax 49 8671 73513 Homepage www galaxis showtechnik d...

Reviews: