Pulley, motor and absorber
1
①
Remove the back cover
②
Loosen the big screw nut from the pulley and take out
the belt
③Remove the pulley
2
①
Take off the motor connection plug wire
②
Remove two bolts from motor holder, and take out
the motor bush.(picture 14)
③
Follow the arrow to take off the motor (picture15)
④
Ensure the bush is in the motor holder while reset the
motor
14
15
3
①
Remove the fixed bolt from absorber.
②
Take out the absorber
③
Ensure tighten the fixed bolt while reset the absorber
to avoid the noise from spin
Clear draining pump filer
1
⒉
Turn filer left and take off the water pump
filer(picture 16)
②
Clear the stuff from water pump filer(photo 17)
③
Put back the filer in to right position after clear
⒉
Please well set the dam-board after well set the
filer
16
17
Water pump
①
Remove the control panel, dam-board and front cover
②
Remove two bolts from water pump
③
Remove water pump wires
④
Hole the water pump pull up
⑤
Remove all the hose from water pump
Remove the pump (remark: photo 8 shows the well
set water pump)
18
Summary of Contents for XQG60-A708E
Page 7: ...6 1 Program knob 2 temperature 3 start pause 4 Power 4 Electrical diagrams circuit diagram...
Page 8: ...7 5 Error indication analysis...
Page 15: ...14 6 1 3 Inside door AS 6 1 4Outside door AS...
Page 16: ...15 6 1 5 Control panel AS 6 1 6 Drum AS...
Page 17: ...16 6 1 7 Drying AS Attention this picture only for the washer combine with dryer machine...
Page 18: ...17 6 1 8 Top Cover AS...
Page 19: ...18 6 2 components exploded view...
Page 20: ...19 10 2 1 Drum AS...
Page 21: ...20...