3.5.1 TIG STD.
E2: ADJUST WELDING CURRENT
3.5.2. TIG PULSE.
E1: ADJUST FRECUENCY
E2: ADJUST WELDING CURRENT
3.5.3. PARAMETERS SETTING MODE. TIG PROCESSES.
P1: SELECT PROCESS
P1: ENTER TO SETUP
E1: SELECT CYCLE PARAMETER
E2: ADJUST VALUE
P1:
SAVE PARAMETERS
(2”)
(2”)
PARAMETER
RANGE
UNIT RESOLUTION RESET
STD
PULSE
MOD
Torch Mode
VAL-2T-4T
--
--
2T
REF
Cooling unit mode
OFF-ON-AUT
--
--
OFF
Restrictions mode
VAL 2T
4T
VAL
2T
4T
TPR
Gas pre-flow time
0,0-5,0
s
0,1
0,3
IS
Initial current
10-100
%
1
30
UPS
Up Slope
0,0-10,0
s
0,1
0,4
IB
Base Intensity
10-100
%
1
50
DCL
% Upper Intensity Bipulse
20-80
%
1
50
DWS
Down Slope
0,0-10,0
s
0,1
0,6
IE
End crater current
10-100
%
1
30
TPS
Gas post-flow time
0,0-10,0
s
0,1
0,4
3.6. JOB RECORDING MODE.
P4 : BURN JOB
E2: SELECT Nº JOB
P4: SAVE JOB
(2”)
(2”)
3.6.1. LOAD JOB
P1: SELECT PROCESS
P4: ENTER TO JOB MODE
E2: SELECT JOB
D1: JOB SELECT
Note: if the message
JOB
appear on display D1, this is indicative that there are not programs recorded.