USER INTERFACE
CODE
SYMBOL
DESCRIPTION
L1
Illumination shows that the following function has been activated: Q-START
L2
Illumination shows that the following function has been activated: DYNAMIC ARC
L3
Illumination shows that the following function has been activated: MULTI TACK
L4
This LED illuminates to confirm the presence of power on the output sockets.
L5
This LED illuminates to show an anomaly in the operating conditions.
See “ALARMS MANAGEMENT”(§ 9 page 32).
L6
Illumination shows that the following function has been activated: 2 times Spot procedure
§ 13g page 41 / § 13h page 41
L7
When this LED illuminates the following parameter can be set: TIG SYNERGIC PULSE
When this is on, it means that the synergic mode is active and that the operator can set just the welding current while the other parameters
are automatically regulated by the machine. The synergy is optimised by angle welding.
L8
Illumination shows that the following function has been activated: High frequency arc strike (HF)
L9
This LED indicates that the current reference setting is imposed by the remote controller.
L10
Illumination shows that the following function has been activated: 2 times procedure
§ 13a page 40 / § 13b page 40
L11
Illumination shows that the following function has been activated: 4 times procedure
§ 13c page 40 / § 13d page 41
L12
Illumination shows that the following function has been activated: 4 times Bi-level procedure
§ 13e page 41 / § 13f page 41
L13
This LED illuminates to show that the following welding mode is selected: MMA
L14
This LED illuminates to show that the following welding mode is selected: TIG CONTINUOUS
L15
This LED illuminates to show that the following welding mode is selected: TIG PULSED
D1
Parameters/functions setting: 1st level menu:
The displays show the value of the following parameter: WELDING CURRENT
Parameters/functions setting: 2nd level menu:
The displays show “L.2“.
Welding:
The displays show the value of the following parameter: WELDING CURRENT
D2
Parameters/functions setting:
The displays show the selected parameter and its value.
Welding:
The displays show the average instantaneous voltage value.
HOLD function:
The displays show the average voltage value of the last weld executed.
The "HOLD" value is cleared when a new weld is started, or when any action is performed on the user interface.
S1
DC TIG mode:
Press the button to select the parameter to be set. Possible choices:
-
Q-START
-
DYNAMIC ARC
-
MULTI-TACK
S2
Press the button once to open the JOB upload menu.
Hold down the button for 3 seconds to gain access to the JOB save/delete menu.
S3
Press the button once to select the parameters of the first level menu.
Hold down the button for 3 seconds to gain access to the second level menu.