4
1. Performance and Main Features
2. Application Areas
3. Bactericidal Factors and Strength
4. Microbial Category
5. Technical Parameter
gako UV-C Air Sterilizer
is a device designed for air disinfection using
high-intensity germicidal lamps, a method that can be used for safe disin-
fection of environments where health professionals, patients, students, and
people in public places are exposed to contagious risk factors.
gako UV-C Air Sterilizer
is suitable for dynamic indoor air disinfection in
pharmacies, medical examination cabinets, waiting rooms, hospitals, food,
beverage and pharmaceutical factories, restaurants, schools, universities,
or any other environment with constant people circulation and potential
contamination risk.
The main bactericidal factor used is ultraviolet irradiation (UVC) through
short wavelength ultraviolet. The UV lamps in the
gako UV-C Air Sterilizer
device meet the technical requirements achieving 254nm wavelength.
Germicidal lamp is a special type of lamp that produces UVC light. This
short wave ultraviolet light disrupts DNA base pairing, causing formation of
pyramidine dimers and leads to the inactivation of microorganisms such as
bacteria, virus and protozoa.
According to the electric shock protection, product classifies
as: Class II, Type B, general equipment. CE Certified.
Table 1.0: Technical Parameter gako UV-C Air Sterilizer.
Model
gako UV-C Air Sterilizer
Power Supply
1AC220V±10%; 50/60Hz
Temperature
-10ºC ~ 40ºC
Humidity
≤ 80%
Air Pressure
600hpa � 1060hpa
Applicable Room
≅
80m3
Circulating Air Volume
≥ 800m3/h
UK Leakage
≤ 5µw/cm2 (30cm from the device)
Noise
≤ 55db
Consuption
≤ 260W
Summary of Contents for UV-C
Page 1: ...gako UV C Air Sterilizer User Manual ...