07/14
Models 393-800A, 393AL-800A, and 394AL-802A
The mounting and wiring instructions are as follows:
1.
Remove the four security screws from the
front panel.
2.
Position the enclosure on the mounting
surface. The enclosure provides four
0.28-inch mounting holes in a 7.0
8.5-inch
hole pattern. Secure the enclosure to its
mounting surface with four ¼-inch diameter
bolts of the appropriate length for the surface.
N
OTES
:
1. When using the GAI-Tronics Model 231-
001 Pole Mounting Kit, follow the mounting
instructions provided in the kit.
2. When mounting outdoors, installation of a
surge suppresser (customer-supplied) on the
power line is recommended.
3.
For Model 393-800A only: Create a conduit
access hole using a Greenlee-type punch that
is equivalent in size to the conduit diameter.
Bottom entry is strongly recommended. Insert
a conduit fitting in the access hole.
4.
Install conduit as required. Refer to conduit installation details on page 7.
N
OTE
:
Use silicone sealant or equivalent around and inside all conduit entries.
5.
Pull the power and ground cable through the conduit and install the cable as shown in the “Field Wire
Installation” section on page 13.
N
OTE
:
If mounted outdoors, the installation of a surge suppressor (customer-supplied) on the power
line is recommended.
6.
Connect any desired peripheral devices. Refer to page 17 for connection information.
7.
Perform the initial programming of the telephone. Refer to the “Programming” section on page 19.
8.
Verify operation by calling to and from another telephone.
9.
Complete the installation by attaching the front panel assembly to the rear enclosure using the four
security screws, 10–12 in-lbs. of torque recommended.
Figure 5. Model 393-800A VoIP Telephone in a