Installation
ITR1000-001 Basic Tone Remote Desk Set
02/12 12
Equipment Required
Test Equipment
RF service monitor
AC voltmeter with dB ranges for measuring audio levels
#1 Phillips screwdriver
1/8-inch flat blade screwdriver
Documentation
base station’s tone remote adapter manual
these installation instructions
Cable Installation Safety Considerations
Interconnecting, communications, and Class 2 dc power cables should be separated from electrical light
or other Class 1 circuits by at least 2 inches. The exception is where Class 1 wiring or power circuits are
run in a raceway, or are metal-sheathed or metal-clad, or are permanently separately from the conductors
of the other circuitry by a continuous and firmly fixed nonconductor such as porcelain tubes or flexible
tubing in addition to the insulation on the wire. Communications cables and in-building wiring should be
listed and marked for the purpose according to NEC Article 800.
Telephone Line Lightning and Over-voltage Protection
The ITR1000-001 Basic Tone Remote Desk Set has an over-current phone line fuse (F2) which protects
against occasional extreme fault conditions that may get past the primary protectors. An example of such
a fault condition is a power line cross. If the fuse requires replacement, replace F2 only with the same
type Bussmann C515S 1.25A fuse.
For maximum surge and lightning protection, building primary (over-voltage) protectors should be
installed at the point where the telephone lines enter the radio equipment building. Primary protectors
are usually required by local codes and should be provided by your leased line provider.
Power Connections
Power is applied to the ITR1000-001 from the provided ac wall transformer that is supplied with the unit.
Power is applied to TS1-6 (+, lead with white dashed stripe) and TS1-5 (
−
).