Pub. 42004-550C 

 

G A I - T R O N I C S

®

 

A   H U B B E L L   C O M P A N Y  

Elemec3 Console Manual—Version 3

 

T

A B L E   O F  

C

O N T E N T S

 

GAI-TRONICS  3030 KUTZTOWN RD.  READING, PA  19605 USA 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

Confidentiality Notice .....................................................................................................................1

 

Introduction .....................................................................................................................................1

 

The Programming Process .............................................................................................................1

 

Process Flow ............................................................................................................................................ 2

 

E3 Console Process Flow ........................................................................................................................ 2

 

Install the E3 Console Application .................................................................................................7

 

Run the E3 Console Application ....................................................................................................7

 

Manage Configurations .......................................................................................................................... 8

 

LOCAL CONFIGURATIONS (Working Directory) ........................................................................... 8 
REMOTE CONFIGURATIONS (Parent Directory) ............................................................................ 9 

Create New Configuration ..................................................................................................................... 9

 

Create New Configuration from Template ......................................................................................... 10

 

Load an Existing Configuration .......................................................................................................... 10

 

System-Wide Functions ........................................................................................................................ 11

 

System Properties ..........................................................................................................................12

 

Globals ................................................................................................................................................... 12

 

Global Settings .................................................................................................................................... 12 
Network Settings ................................................................................................................................. 14 

Locations ................................................................................................................................................ 15

 

Ack/Cancel Configuration .................................................................................................................... 15

 

Create an Ack/Cancel Action.............................................................................................................. 15 
Delete an Ack/Cancel Action.............................................................................................................. 16 

User Flags .............................................................................................................................................. 17

 

System Flags .......................................................................................................................................... 17

 

Manage Global Mutes ........................................................................................................................... 18

 

Global Audio Mix Setup ....................................................................................................................... 18

 

Amplifiers ......................................................................................................................................20

 

D600i, D300i, and D550i Power Amplifier Properties ....................................................................... 21

 

GAI (Generic Amplifier Interface) Properties ................................................................................... 22

 

Hot Standby Amplifiers ........................................................................................................................ 23

 

Speaker Masters ............................................................................................................................24

 

Summary of Contents for Elemec3 013-02-0095-002

Page 1: ...ation 7 Manage Configurations 8 LOCAL CONFIGURATIONS Working Directory 8 REMOTE CONFIGURATIONS Parent Directory 9 Create New Configuration 9 Create New Configuration from Template 10 Load an Existing...

Page 2: ...tup 31 Remove Button 32 Close Button 32 Access Panel Button Configuration 32 Button Properties 33 Create and Modify AP Buttons 33 Reset Buttons 34 Print Preview 34 Close 34 IP Access Panels 35 IP Acce...

Page 3: ...rty Audio Input Properties 60 Telephone Interface Audio Input Properties 61 VoIP Telephone Interface Setup 62 SIP Properties 63 SIP Registrar Configuration 64 SP2 Properties 65 Auxiliary Inputs 1 5 Au...

Page 4: ...IONS 86 ADD IP DESTINATION 87 SP2 Integration 87 Configuration Parameter Field Flags 88 Parameter Panes 89 Station Parameter Configuration and Precedence 89 I O States 90 System Properties Screen 91 G...

Page 5: ...8 Manage Global Mutes 18 Figure 19 Global Audio Mix Setup 19 Figure 20 Amplifiers Summary 20 Figure 21 Add Amplifier 20 Figure 22 Amplifier Properties 21 Figure 23 Amplifier Address Assignment Conflic...

Page 6: ...67 Page Party Audio Input Properties 60 Figure 68 Telephone Interface Audio Input Properties 61 Figure 69 VoIP Telephone Interface Setup 62 Figure 70 Configure SIP Registrar Properties 63 Figure 71 C...

Page 7: ...e on the Stations Screen 93 Figure 107 Manage Profiles Screen 94 Figure 108 Profile Selected 94 Figure 109 Global System Settings Pane 95 Figure 110 Page Receive RX Sockets Pane 96 Figure 111 Page Tra...

Page 8: ...to incorrect programming resulting in a potentially life threatening situation Usage of the E3 Console and E3 Portal applications should be strictly limited to individuals who are factory trained and...

Page 9: ...iguration to a preset storage location on the host computer called the Elemec bridge Optionally store the configuration file to a custom location using the BROWSE button to select where to save the fi...

Page 10: ...mplifiers Select the amplifier type Edit the amplifier description Set the channel ID 1 64 Set channel zone display Enable disable load testing Identify if channel is a standby amp Amplifiers on page...

Page 11: ...Background Music on page 72 7 Import Sound Files for Pre Recorded Messages Action Screen Browse and select an mp3 file Import the mp3 file it into the configuration file Playback Audio Import MP3 on p...

Page 12: ...mode repeat continuous Select the cancel and acknowledgement options Select the default broadcast zone Select the output and logic flags to activate Select an event chain Event Builder on page 75 For...

Page 13: ...es Summary screen on page 28 Edit the access panel description Set the access panel address 0 F Enable disable supervision Access Panel Properties screen on page 30 Program the inputs to the I O contr...

Page 14: ...tions Run the E3 Console Application Start the Elemec3 Console application from the Start Menu Go to Programs GAI Tronics Corporation and click on ElemecConsole3 Optionally double click the desktop sh...

Page 15: ...remote storage locations to the local working directory to work on them Export a configuration file back to a remote custom storage location or to the Elemec3 bridge folder for upload to an E3 control...

Page 16: ...lemec3 configuration storage location on the local computer that is common with the E3 Portal application The Elemec bridge is useful when running the E3 Console and E3 Portal applications on the same...

Page 17: ...nge incrementally with the release of new software Figure 6 Invalid Database Version 3 Click UPGRADE DATABASE to proceed with the configuration version upgrade otherwise click CLOSE Load an Existing C...

Page 18: ...loaded configuration Choose SAVE CHANGES or DISCARD CHANGES as desired to continue to the CREATE NEW CONFIGURATION screen see the Create New Configuration section Save saves the currently loaded conf...

Page 19: ...ings System Type Select the system type using the pull down menu Standalone System a system consisting of a single E3 controller with associated amplifiers access panels I O controllers etc A B System...

Page 20: ...XILIARY AUDIO OUTPUT ONE terminals on the E3 controller See Pub 42004 497 Elemec3 System Controllers for event recorder connection information see the Reference Documentation section Enable audio even...

Page 21: ...TWORK CONFIGURATION screen see Figure 13 Use this screen to set the network parameters for the E3 controller s Standalone systems only display one system Enter settings for both controllers for an A B...

Page 22: ...screen to open the MANAGE DEVICE LOCATIONS screen see Figure 14 Locations are text only descriptors associated with any hardware device optional Locations normally specify the physical location of a...

Page 23: ...n action that may acknowledge or cancel all events or just the current event if possible Select BY PRIORITY to enable the configuration of ack cancel actions that act upon events with equal or lower p...

Page 24: ...2 Enter a description and click ADD FLAG Description a unique description for the user flag followAudio specifies if the flag asserts only while the event is active and the event s audio is broadcast...

Page 25: ...h Threshold priority that determines the muting of live speech events The system mutes all live speech events at or below the priority of the selected event The lists shown in the PLAYBACK EVENT MUTIN...

Page 26: ...n with live speech All events at or above the selected threshold will not attenuate playback events when mixed with listed live speech events Not Mixed lists all live speech and playback events not li...

Page 27: ...Y screen see Figure 20 The summary screen displays all amplifiers in the system Figure 20 Amplifiers Summary 2 Click ADD AMPLIFIER to add an amplifier 3 Select the appropriate amplifier model on the A...

Page 28: ...model display below the amplifier graphic The number of channels physically present in the amplifier determines the number of panes displayed onscreen Description generic name for each amplifier chann...

Page 29: ...nnel configures the current channel to be identical to an existing already configured amplifier channel Click COPY CHANNEL to open the ZONE AUTO ASSIGNMENT dialog box This button is available when the...

Page 30: ...ial that the amplifier wiring match the hot standby Elemec3 configuration for proper operation The wiring sequence determines the priority for failed amplifiers switching to the hot standby amplifier...

Page 31: ...o each speaker master audio channel The speaker master powers the speaker remote modules on each channel and transmits power level tap commands and receives speaker coil health check status from the s...

Page 32: ...onsole 3 Assign AUDIO CHANNELS to the speaker master controller Channel 1 Channel 4 Select the amplifier channel to assign to each of the four audio channels Amplifier channels are assignable to only...

Page 33: ...EMOTES to add speaker remotes to the Elemec3 system The CREATE SPEAKER REMOTES dialog box displays 3 Select the amplifier channel to assign the speaker remotes to 4 Use the HOW MANY selector to enter...

Page 34: ...using the drop down list selector The speaker audio output power corresponds to the position of jumper P6 on the speaker remote module and the volume level selected in the E3 Console Table 2 Speaker...

Page 35: ...eckbox to add access panels connected to the physical API card s installed in the system Access Panel Interface Type Selection There are two types of API cards both types permit connection of up to fo...

Page 36: ...the button template layout The button template defines the default button layout for the physical access panels in the Elemec3 system see the Access Panel Button Configuration section Add Access Pane...

Page 37: ...causes the current access panel to swap audio path values with the other panel Audio path assignments of access panels connected to an API type I cards are set by the system Location the physical loca...

Page 38: ...udspeaker s to prevent acoustic feedback through the access panel s microphone The ACCESS PANEL MUTE SETUP screen is divided into five panes see Figure 34 to configure the settings of the local mute r...

Page 39: ...ccess panel from the configuration A confirmation prompt displays unless it is disabled by the DON T SHOW THIS AGAIN application option see the Settings section Close Button Click CLOSE to return to t...

Page 40: ...s type to NOT PRESENT Button Types The following types of access panel push buttons are available Not Present default all unassigned buttons These buttons have a gray top and black bottom Indicator pr...

Page 41: ...ay period for delayed or staged events Any active events currently delayed immediately activate Select the OVERRIDE ALL or OVERRIDE CURRENT radio button Background Music activate deactivate the backgr...

Page 42: ...S SUMMARY screen to add IPAP definitions to the Elemec3 configuration Define a maximum of 16 IPAPs in an Elemec3 system Figure 36 IP Access Panels Summary 1 Click ADD IP ACCESS PANEL to add an IPAP IP...

Page 43: ...but can be acknowledged Urgent fault acknowledgement must occur before clearing the fault Time to Live ttl the maximum number of router hops that the multicast packets traverse before being discarded...

Page 44: ...ting displays the description of the IPAP being configured Page Level Functions Each button page in the IPAP configuration is a button panel in the IPAP application ADD Button adds button pages to the...

Page 45: ...ies Use the IPAP BUTTON PROPERTIES pane to configure the buttons on each button page for the current IPAP Figure 40 IPAP Button Properties There are two BUTTON FUNCTIONS at the right end of the IPAP B...

Page 46: ...t key for the following functionality NEXT PAGE navigate to the next button panel page PREVIOUS PAGE navigate to the previous button panel page HOME navigate to the page defined as home Button Screen...

Page 47: ...button appearance IPAP panels have two tone colors or are black with a color ribbon Button Type displays the button type Button Color Click and select a color from the palette Button Label sets the la...

Page 48: ...tion load that profile s button screen Configure multiple HUBBCOM stations with the same profile PIN to load a common screen on multiple HUBBCOM stations GAI Tronics publication 42004 531 covers downl...

Page 49: ...BBCOM screen in the position they occupy in the list Create and insert a blank button to place functional buttons in the desired position on the HUBBCOM APLite screen 5 Click CLOSE to return to the AP...

Page 50: ...n Style Select the desired button style color ribbon or solid color from the drop down list Preview view only field displays what the button will look like 3 Click CLOSE to return to the previous scre...

Page 51: ...the E3 controller and the IP I O devices on the network All IP I O devises communicate on the same control socket The socket number consists of a multicast IP address and port number separated by a c...

Page 52: ...n I O controller to the system 2 Select one of the seven types of I O controller on the ADD I O CONTROLLER screen see Figure 49 NOTE The IP controller only supports IP I O controllers 3 Click ADD DEVI...

Page 53: ...s Monitored Relay Module 8 relay outputs with 8 optionally supervised inputs Beacon Monitor 8 supervised outputs with monitoring for power distribution circuits IP Monitored Input Module 8 optionally...

Page 54: ...42004 550C docx 07 21 Figure 51 Elemec I O Controller Properties Description a generic unique name for the I O controller generated by default Location A the location of the I O controller card see th...

Page 55: ...er The first input on I O card zero is 0 1 the second input on card zero is 0 2 and so on The properties for each input appear in the columns from left to right across the inputs tab and define the ad...

Page 56: ...s first so they have addresses 0 1 through 0 8 The output property fields appear from left to right across the outputs tab see Figure 54 and Figure 55 Configure the relay state in column two to enable...

Page 57: ...t Contact Definitions Inhibit Groups Inhibit groups allow for selectively inhibiting inputs to the Elemec3 system Configure system inputs to trigger an inhibit group that inhibits all inputs in the gr...

Page 58: ...e descriptive name of the inhibit group Available Inputs Pane Select enabled input contacts on the I O controller cards listed in the AVAILABLE INPUTS pane for addition to the ASSIGNED list The AVAILA...

Page 59: ...elays the initial transition to active The output remains active for the duration of the on time setting The output remains idle for the duration of the off time setting The output then continuously c...

Page 60: ...plication consists of a network with multiple servers i e instruments or PLC inputs outputs and one or more clients e g PLC CPU or SCADA system Unique IP addresses identify each client and server The...

Page 61: ...to configure the Modbus TCP server parameters Modbus TCP modules have two tabs on their property screens INPUTS and OUTPUTS Inputs allow Modbus clients to trigger events in the E3 system Outputs allow...

Page 62: ...e until an event CANCEL command is issued to the E3 controller Trigger event to trigger when the input coil is ON Auto Inhibit the auto inhibit key switch ignores triggered events when the input coil...

Page 63: ...output Modbus coil 2 Configure the COIL ADDRESS DESCRIPTION MODE and FOLLOW AUDIO properties for the output 3 Click REMOVE to delete the selected output from the list 4 Click CLOSE to return to the MO...

Page 64: ...active while the input coil is on and immediately cancels when turned off by a Modbus client Momentary The event is active when the discrete input coil is ON and remains active until an event CANCEL c...

Page 65: ...ly OFF The output Modbus coil is OFF data 0000 when the event is inactive The output Modbus coil is ON data FF00 when the event is active Follow Audio assuming the event is a playback type the output...

Page 66: ...rioritized list Sources Enabled The SOURCES ENABLED checkboxes enable the live audio sources in the E3 system 1 Select the check boxes for the audio input sources in the Elemec3 system Each input appe...

Page 67: ...m on any of the enabled audio input sources see Insert 1 Enabled Insert 2 Enabled Event Choose the event from the dropdown list that will initiate when the controller detects audio on the Page Party i...

Page 68: ...e Interface the E3 controller uses the VoIP telephone interface instead of an analog PSTN connection for all telephony functions This removes the Ring Count A System property and replaces it with a VO...

Page 69: ...audio to remove at the end of the playback The STOP TRIM duration is dependent on the operation of the PBX at call termination Ring Count A System number of rings before the telephone interface answer...

Page 70: ...interval may be different than the value entered Keep Alive Interval time seconds that the E3 controller sends keep alive messages to ensure the port remains open Set this number to zero 0 to disable...

Page 71: ...egistrar IP PABX Extension extension number assigned to the telephone interface by the SIP Registrar Authentication ID account username assigned by the SIP Registrar Authentication Password account pa...

Page 72: ...e PARTY MAX DURATION allowing the call to continue if needed The caller hears a beep indicating the party line time limit is about to expire 1 Press the button on the telephone s keypad to extend the...

Page 73: ...tion maximum duration of an auxiliary input broadcast Start Trim recording delay at the beginning of a record playback event seconds Stop Trim amount of playback audio to remove at the end of the play...

Page 74: ...address of the multicast input Multicast Port IP port of the multicast input Zones Use the ZONES configuration screen to create and manage communication zones in an Elemec3 system A zone is a set of o...

Page 75: ...en see the Globals section to enable the option here Beneath the ZONE DESCRIPTION field are four selectable audio outputs Select the audio outputs to include in the zone The available audio outputs ar...

Page 76: ...button to move selected zones to the ASSIGNED AUDIO DESTINATIONS list on the right IP Destinations add previously defined IP destinations to this zone Select the IP DESTINATIONS from the AVAILABLE DES...

Page 77: ...docx 07 21 Figure 76 Playback Audio Configuration Playback Audio Configuration Add Message Click ADD MESSAGE on the PLAYBACK AUDIO CONFIGURATION screen to open the CREATE NEW MESSAGE screen Figure 77...

Page 78: ...ESSAGE to have user logic flag s with the same description as the message automatically added to the created event s Create New Message Click CREATE NEW MESSAGE to finish creating the message Import M...

Page 79: ...amplifier audio path and load tests The background music resumes when the tests are complete Messages The MESSAGES pane lists the messages for use with the E3 system Messages consist of one or more m...

Page 80: ...SEQUENCE pane Select a message fragment in the MESSAGE FRAGMENTS list to access the play button Press the green play button to listen to the fragment Message Sequence Change the playback sequence of...

Page 81: ...created with the AUTOMATICALLY CREATE EVENT option are in the EVENTS AND EVENT GROUPS pane Add Event Click ADD EVENT to open the CREATE NEW EVENT OBJECT screen Enter a description for the event objec...

Page 82: ...the event type selected see the Event Options section Behavior Playback and External events only event behavior for playback and external audio events Normal attempts to play the specified message imm...

Page 83: ...parison to the VLC threshold parameter configured on the SP2 station using the VLC AMP MODE operator to perform the comparison EDIT STAGED Click EDIT STAGED to configure the staged portion of an event...

Page 84: ...S Select each output type as necessary and then select the items in the list to add and click the right pointing arrow button to add them to the ASSIGNED list For each I O card Only the enabled output...

Page 85: ...e otherwise the event plays only in the available destinations i e play where possible VLC Enabled system broadcasts a VLC Volume Level Control tone to the Page Party output Event Options Use the EVEN...

Page 86: ...use to source audio for an event via an input contact on an I O card Use this setting whenever an input source doesn t have its own push to talk PTT capability Select the SOURCE from the drop down for...

Page 87: ...the event Auto cancel the event manually or it will cancel automatically after the Auto Cancel Delay expires Auto Cancel Delay delay seconds for the event to cancel Event Acknowledge Ack Required an a...

Page 88: ...than a standard event Use event groups to sequence alarms when multiple events are active simultaneously The maximum number of event groups is 16 There are three types of event groups standard sequenc...

Page 89: ...ent NOTE The E3 controller requires NTP Network Time Protocol service access to implement scheduled events Figure 91 Scheduled Events Select Region Country Select the region or country for the E3 syst...

Page 90: ...r the period of the event Month s of Year Select EVERY MONTH or the individual months of the year Day s of Week Select EVERY DAY or the individual days of the week Week s of Month Select EVERY WEEK or...

Page 91: ...access panel status indicators Normal faults automatically acknowledge when the fault clears URGENT access panels status indicators show an Urgent fault Urgent faults are critical system faults that...

Page 92: ...lable IP AUX INPUTS and IP AUX OUTPUTS These inputs and outputs are part of the system and are not removable Figure 95 System IP Aux IP Inputs Enable the necessary auxiliary IP inputs on the SOURCES E...

Page 93: ...at the analog MONITOR OUT transmits from the system Figure 96 Edit IP Output Properties Multicast Group IP address for the IP aux output Multicast Port port address for the IP aux output Time to Live...

Page 94: ...ations to any zone see the Zones section SP2 Integration E3 systems integrate SP2 SVS HUBBCOM devices to add the features and flexibility of these systems The E3 Console implements portions of the SP2...

Page 95: ...configuration location for that setting in the SP2 configuration The flags display as colored triangular overlays on the upper left corner of each parameter field label and match the color of the loca...

Page 96: ...TEM PROPERTIES level in the SP2 configuration hierarchy in the E3 Console They appear with slightly dimmed flags to indicate they have default settings Change the value assigned to an attribute at thi...

Page 97: ...set is off hook ON Always ON OFF Always OFF HEALTHY The station is not detecting any fault conditions FAULTY The station is detecting a fault condition LINKUP The network interface physical link is up...

Page 98: ...xpands by default see the Global System Settings section Figure 102 System Properties Pane with Global System Settings Pane Expanded Groups Screen Click the GROUPS button at the top of the screen to a...

Page 99: ...values to attributes at the group and station levels of the hierarchy To assign a profile to a group click the PROFILE field label and select profile one through nine from the dropdown list see the Pr...

Page 100: ...dress cycle through the SP2 stations that have identifiers in the system This allows browsing to a different station s settings without having to use the station list utility Hostname this station s n...

Page 101: ...nted in a profile override the previously set value for all parameters assigned in the profile Figure 107 Manage Profiles Screen Select a Profile Click on a profile number to select it Figure 108 Prof...

Page 102: ...ation file by one whenever making a change to the configuration The SP2 stations use this in conjunction with the CRC of the file to determine whether to use and save these parameters Provisioning Soc...

Page 103: ...ticast Sockets section Incoming Page Routing The AUDIO OUTPUT fields control the destination of received page audio Select 600OHMOUT SPEAKER or BOTH using the drop down list for each AUDIO OUTPUT Page...

Page 104: ...in the E3 Console for use in the E3 system Audio Settings Figure 113 Audio Settings Pane Volume Settings Mute Speaker mutes incoming pages during page transmission on any PAGETX socket A E Valid setti...

Page 105: ...of the 600 ohm audio output for page lines configured for 600 ohm output The value represents the amplitude in millivolts RMS If the Page Destination parameter is set to BOTH then the value stored in...

Page 106: ...S utility see the VLC Levels section Assign VLC levels to events see the Event Builder section to configure the VLC priority level for the event Assign the VLC levels to SP2 stations on the VLC Settin...

Page 107: ...rt paging to the PAGETX_B_SOCK multicast address Do not press the handset pressbar to initiate the page Pressing the handset pressbar without holding the ALL CALL button initiates a page on PAGETX_A_S...

Page 108: ...guration limit the available options All options are available at the remaining configuration levels RTU OUT specifies what activates the RTU output on the station RS IN 1 RS IN 2 specifies the remote...

Page 109: ...ibit specifies the inhibit groups that affects the SVS inputs see the Inhibit Groups section SVS Volume Settings SVS Amplifier Volume the default volume for SVS stations SVS POE Volume the volume leve...

Page 110: ...t IP port address of the SNMP service on the SNMP server RTU RS IO See the RTU Settings Excluding SVS section SVS I O Settings See the SVS Settings SVS Only section SP2 Configuration Assets SP2 config...

Page 111: ...event VLC Levels VLC levels allow setting volume levels independently by event or source Click to create a new VLC level A new VLC level with a default description VLC Level N appears in the VLC PRIO...

Page 112: ...xists in the configuration a prompt to add the station to the configuration if the station is not found see Figure 120 Click the CREATE STATION button to add the station s ID to the configuration or C...

Page 113: ...oup selector switch set to the selected group number 0 F Add Stations to Group opens the dialog box at the right to add stations to the configuration in the group selected above STATIONS TO ADD the nu...

Page 114: ...the configuration to the Elemec Bridge location for upload to an E3 controller using the E3 Portal application Save as Copy saves the current configuration with a new name Save Configuration Changes...

Page 115: ...vation requests in accord with the configuration Contingent Override A type of event group that automatically substitutes a general event to occur if multiple specific events initiate Elemec3 Portal S...

Page 116: ...r This type of system has no backup in the case of controller failure System Flag One of several logic outputs without relays originating within the Elemec3 system that provide real time active idle s...

Reviews: