Description 

 

Features and Benefits 

Feature Benefit 

LCD display 

Allows user-friendly interface; displays zone and alarm, status and 
diagnostic information. 

Programmable buttons 

Four buttons provide up to eight user-defined actions, i.e., 
preprogrammed zone and alarm selection, button remapping, output 
control, etc. 

DTMF Control for Model 133x2 
Series Amplified Addressable 
Speakers and GAI-Tronics SBA 
and SBM Stanchion assemblies. 

Generates the necessary control tones to address the GAI-Tronics 
Amplified Addressable Speaker series and Stanchion Broadcast 
products. 

Hot-Standby Control 

Additional units can be connected for hot standby control in case of 
primary failure.  (Requires relay control option to be installed.) 

External Event Notification 

LCD indicates external Audio Messenger Interface (AMI) event activity 
such as contact closure or phone call. 

Direct AMI Audio Monitoring 

User can hear all audio being generated by the AMI whether originated 
from the ACC2500 or external event such as a timed event or telephone 
broadcast. 

Live Broadcast 

Supports live broadcast with zone selection  

Front-mounted controls and 
adjustments 

Includes mute/unmute and local speaker on/off. 

Preannounce tone 

When programmed in the Audio Messenger Interface (AMI), a 
preannounce tone will be generated prior to live broadcast from the unit 
speaker and all addressed speakers/stanchions. 

Built-in internal mic and speaker 

Allows for single push-button communication. 

Programmable inputs and outputs  Inputs and outputs can be configured for a variety of selections.  

(Requires relay control option to be installed.) 

 

Summary of Contents for ACC2500

Page 1: ...Ave Mohnton PA 19540 USA 610 777 1374 800 492 1212 Fax 610 796 5954 VISIT WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS G AI T RO NI CS CO RPO RAT I O N A H U B B E L L C O M P A N Y Model AC...

Page 2: ...t shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Limitations Exclusions The warranty on any equipment supplied hereunder is...

Page 3: ...ALARM 13 Handset Transmit 14 Transmit from Internal Local Microphone 14 Transmit from Desk Microphone or Footswitch 14 ALARM SELECTION 15 INITIATING ALARM BROADCASTS WITHOUT VOICE 16 STOPPING THE BROA...

Page 4: ...AUDIO 32 MICROPHONE AUDIO 32 RELAY CONTROL MODULE 32 RESET CIRCUIT 32 CARD SUITE PROGRAMMING SOFTWARE 33 GENERAL DESCRIPTION 33 CONNECTION 33 INSTALLATION 33 READING THE UNIT 33 CARD SUITE PROGRAMMIN...

Page 5: ...actory for repair Please call 1 800 492 1212 to obtain a Return Authorization number published repair prices and shipping instructions A Return Authorization number can also be obtained by visiting ou...

Page 6: ...areas dry environments and certain types of clothing silk nylon etc because they contribute to static build up Similarly disconnect the test probe prior to removing the ground lead 5 All electrically...

Page 7: ...option to be installed External Event Notification LCD indicates external Audio Messenger Interface AMI event activity such as contact closure or phone call Direct AMI Audio Monitoring User can hear...

Page 8: ...f zones via the numeric keypad or selection of zones using a preprogrammed alias programmed using the CARD Suite software application In addition the unit allows direct entry of preprogrammed alarm me...

Page 9: ...arms See the Operations section of this manual for further information STOP CLR Button The STOP CLR button serves two purposes While an alarm is being generated pressing the STOP CLR button will stop...

Page 10: ...n with the CTL button Depending on its configuration the selected button illuminates when it is pressed Internal Microphone and Speaker This microphone is intended for use in low noise environments Th...

Page 11: ...c The 5 pin power connector diagram and pinout are shown below Pin Function 1 IN 2 Battery backup IN 3 IN 4 IN 5 IN AMIConnections The rear of the ACC2500 contains two modular ports used to connect to...

Page 12: ...un terminated Connection of these pins may damage the ACC2500 or AMI and may not be covered under warranty To facilitate the connection of these two ports to the AMI the 69612 xxx purchased separatel...

Page 13: ...Kit XRC0001A Mounting Kit for Option Boards XAC0100A Power Supply 120 V ac 60 Hz 3308 00750 00 Power Supply 110 220 V ac 50 60 Hz 3308 00750 10 Desk Microphone XDM002A Gooseneck Microphone XGM002A Am...

Page 14: ...I SELV powered equipment Powered by UL listed E104603 and CSA certified LR67888 Class 2 ac adapter Emissions USA FCC Part 15 Sub B Verification Canada ICES 003 Line interface FCC Part 68 Exempt Catego...

Page 15: ...play to provide valuable operator information This information allows the operator to determine the status of the unit The following describes the display at various states At power up Initially line...

Page 16: ...ct the desired zone This zone is displayed on the first line of the LCD display Note that during installation and programming the zone label can be changed to a desired display using the CARD Suite ap...

Page 17: ...a second time clears the zone entry Initiating Live Voice Broadcasts without an Alarm After selecting the desired zone the operator may initiate a live broadcast immediately by pressing and holding an...

Page 18: ...Handset Transmit Use of the handset is recommended when the desk set is located in noisy surroundings Press the handset PTT bar or TRANSMIT button and speak into the handset microphone to transmit wh...

Page 19: ...and the last digit will become the first digit of the new alarm After entry of the alarm the display will be as shown below Z o n e Z o n e 3 A l a r m _ 1 2 The alarm aliases differ from the zone ali...

Page 20: ...display will be as shown below AC T I V E Z o n e 3 A l a r m L o c k D o w n ACTIVE Alarm and the alarm name will be flashing indicating that the selected zone has been activated is within its time...

Page 21: ...ONE or ALARM buttons during alarm broadcast Leaving the selected field units active will allow the selection of a new alarm without requiring the regeneration of the DTMF sequence to activate the curr...

Page 22: ...ontrol the field units volume or to add in additional field units by specifically dialing the address of the desired field units The feature is only available while ACTIVE is flashing on the first lin...

Page 23: ...st the local speaker volume if the handset is on hook The handset speaker volume is adjusted if the handset is off hook The display shows the new setting for two seconds after a volume change The inte...

Page 24: ...ator to increase the sensitivity of the internal microphone when on hook or the handset microphone when off hook TRANSMIT VOL Down If the microphone sensitivity feature is enabled allows the operator...

Page 25: ...21 09 08 Installation Planning the Installation Typical ACC2500 Connection Diagram Hot Backup ACC2500 Connection Diagram Requires the optional XRC0001A relay board and connection per Table 1 below...

Page 26: ...ls pertaining to Class A and Class B computing devices contain warnings about possible interference with local and residential radio and TV reception Please read these warnings and all safety informat...

Page 27: ...nuous and firmly fixed nonconductor such as porcelain tubes or flexible tubing in addition to the insulation on the wire Interconnecting cables longer than 2 meters should be rated VW 1 or FT 1 or gre...

Page 28: ...een 1 and 5 To confirm the absolute level measure the transmit level across the TX line pair using an ac millivolt meter or dBm meter 4 After the adjustment has been made press and hold the IC button...

Page 29: ...idetone Level Adjust Default 0 dBm PB2 DTMF Level Adjust Default 0 dBm PB3 AMI Message Diagnostic TIME Set Current Time and Date ReloadingFactory Defaults Desk sets are shipped from the factory with d...

Page 30: ...s the PB1 button The display will indicate the current setting which is set at the factory at 10 dBm The range for this setting is variable from off to 12 dBm See the Line Output Adjustment table for...

Page 31: ...e if the audio from the AMI is 0 dBm and the audio line has 10 dB of line loss the line input sensitivity should be set to level 4 9 dBm to accommodate the 10 dB of incurred line loss After pressing t...

Page 32: ...s relay 1 of the relay option board This connects the RS 232 data from the AMI directly to the primary unit When power to the primary unit is lost the RS 232 connection will be made to the backup unit...

Page 33: ...keyboard diagnostic PB4 Tone AlarmDiagnostics This function is accessible via Main Diagnostics mode select PB4 and allows adjustment of the levels of sidetone PB1 and the DTMF tones PB2 The tone leve...

Page 34: ...er programmer to retrieve the message number as stored in the AMI of each message alarm Upon entry into this diagnostic the message number and alarm name of the first message in the list will be displ...

Page 35: ...ed by the DSP to keep the receive audio below the maximum level of approximately 6 dBm After the receive audio has been properly compressed it is passed to A D section of U15 where it is converted to...

Page 36: ...crocontroller using U5 C7 Each mic audio is gain compensated by U22 so that the same level is presented to the mic gain stage consisting U12 and U22 The audio is then presented to the A D section of U...

Page 37: ...s not compatible with Windows NT The CARD Suite Programming Application components are contained on CD ROM Please exit all other programs that are running until the installation is complete Place the...

Page 38: ...tures not found on the ACC2500 ZoneFieldName As discussed in the operations section of this manual what is displayed for the zone field name can be changed to any 8 character alphanumeric string To ch...

Page 39: ...tion is in 5 second increments and will require that the field units be set to the same 5 second granularity If set to 0 the ACC2500 will generate the DTMF ZONE address each time a zone is addressed N...

Page 40: ...determine the message number For example the capcode of 123001 12301 and 1231 will all address zone 123 and broadcast message 1 ProgrammableButtons The ACC2500 includes four programmable buttons that...

Page 41: ...perly adjusted AMI Audio is low or distorted Insure that the audio level is properly adjusted for the particular speaker Insure that the line input sensitivity is properly adjusted No or low transmit...

Page 42: ...ing ACC2500 Audio Control Center 09 08 38 Fuse Replacement CAUTION For continued safe operation replace fuses with the same type Fuses F1 and F2 are Bussmann C515S 1 25A SB 2AG Fuse F401 is Bussmann G...

Page 43: ...39 09 08 Circuit Boards...

Page 44: ...Circuit Boards ACC2500 Audio Control Center 40...

Page 45: ...ACC2500 Audio Control Center Circuit Boards 41...

Page 46: ...Circuit Boards ACC2500 Audio Control Center 42...

Page 47: ...43 09 08 Schematics...

Page 48: ...ACC2500 Audio Control Center Schematics 44 Desk Set Line Interface Sheet 1...

Page 49: ...ACC2500 Audio Control Center Schematics 45 Desk Set User Audio I O Sheet 2...

Page 50: ...Schematics ACC2500 Audio Control Center 46 Desk Set Control Microprocessor I O Sheet 3...

Page 51: ...ACC2500 Audio Control Center Schematics 47 Desk Set DSP Block Sheet 4...

Page 52: ...Schematics ACC2500 Audio Control Center 48 Desk Set Tone Key Panel Sheet 5...

Page 53: ...ACC2500 Audio Control Center Schematics 49 Desk Set Power Supply Sheet 6...

Page 54: ...Schematics ACC2500 Audio Control Center 50 Schematic Sheet 7...

Page 55: ...ACC2500 Audio Control Center Schematics 51...

Page 56: ...ACC2500 Audio Control Center 52 Notes...

Reviews: