GAI-Tronics 7325-106 Manual Download Page 5

Pub. 42004-370E 

Model 7325-106 Multi-Party Amplifier Enclosure 

Page 

5 of 6

 

f:\standard ioms - current release\42004 instr. manuals\42004-370e.doc 

09/13 

Maintenance 

Regular inspection and a good preventive maintenance program will increase the reliability of your 
GAI-Tronics station.  The GAI-Tronics Field Service Department can formulate a service contract suited 
to your facility’s specific need for preventive maintenance. 

In addition, the following procedure can be used to keep Page/Party

®

 systems operating effectively. 

WARNING

 

  Before performing any of the following preventive maintenance steps, remove 

all power from the station. 

1.

 

Remove the amplifier from the enclosure. 

2.

 

Visually check the interior of the enclosure for signs of contamination such as dust, condensation or 
process liquid. 

3.

 

Using the No. 10440-002 Maintenance Cable, plug the amplifier into the connector in the enclosure.  
Check, and if necessary, adjust the amplifier to maximize performance. 

4.

 

Reinstall the amplifier in the enclosure.  Ensure that all gaskets and hardware are in place.  Failure to 
install the gaskets, which also act as spacers, can result in damage to the connectors on the amplifiers 
and inside the enclosures and can cause system faults. 

It may become necessary to re-terminate some or all of the enclosures in a system.  If so, strip the wires 
back to clean copper and connect only one wire to each connector to allow for easier future 
troubleshooting. 

Troubleshooting 

The following table lists some hints to aid technicians in troubleshooting. 

Problem Solution 

Feedback occurs 
only during 
page. 

1.

 

If a speaker is close to the station, try using the muting feature in the amplifier 
enclosure at the terminal blocks.  Connect the violet wire at TB1-8 to TB1-7.  
Refer to the wiring diagram. 

2.

 

Ensure that speakers attached to other stations located nearby are not pointed 
in your direction.  If changing the orientation of the other speakers has no 
effect, mutual muting may be required.  Mutual muting silences all the 
speakers within proximity to the affected stations during a page from any one 
of the mutually muted stations. 
Connect the orange wire (spare) to the TB1-7 of all the stations to be mutually 
muted.  

N

OTE

:

 If too many stations are selected, paging coverage can be 

adversely affected. 

3.

 

Check line terminations at the line balance assembly.  Line balance assembly 
connections are critical. 

Crosstalk 
occurs. 

One or more system cable pairs may be improperly terminated.  Visually inspect 
the system cable connections for accidental crossing of the cable pairs or grounds. 

 

Summary of Contents for 7325-106

Page 1: ...rsations on up to five party lines simultaneously The Model 7325 106 is constructed of cast aluminum and is extremely weatherproof and corrosion resistant It is equipped with terminal strips for conne...

Page 2: ...a factor Mounting The Model 7325 106 Weatherproof Metallic Enclosure is supplied with pre drilled cable openings and dual 1 25 inch conduit hubs located on both the top and bottom For these four entri...

Page 3: ...coustic feedback to the handset microphone However while the handset is in use for party line conversations the paging speaker is live to enable paging calls from other stations To disable the mute fe...

Page 4: ...Pub 42004 370E Model 7325 106 Multi Party Amplifier Enclosure Page 4 of 6 f standard ioms current release 42004 instr manuals 42004 370e doc 09 13 Figure 2 Wiring Diagram...

Page 5: ...side the enclosures and can cause system faults It may become necessary to re terminate some or all of the enclosures in a system If so strip the wires back to clean copper and connect only one wire t...

Page 6: ...nnections Internal screw type barrier terminal blocks External controls Rotary selector switch Dimensions 14 50 H 10 38 W 9 6 D inches 368 3 263 6 244 mm Temperature range operating and storage 22 F t...

Page 7: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: