GAI-Tronics 7325-106 Manual Download Page 2

Pub. 42004-370E 

Model 7325-106 Multi-Party Amplifier Enclosure 

Page 

2 of 6

 

f:\standard ioms - current release\42004 instr. manuals\42004-370e.doc 

09/13 

System layout and power cable length are very important when installing Page/Party

 equipment.  

Although it varies for different systems, the general guideline is that the total power cable length should 
not exceed 1 mile (5280 feet) for 120 V ac systems.  The total cable length is the most important 
consideration while cable length between the stations is generally not a factor. 

Mounting 

The Model 7325-106 Weatherproof Metallic Enclosure is supplied with pre-drilled cable openings and 
dual 1.25-inch conduit hubs located on both the top and bottom.  For these four entries, two have hole 
plugs in place and two have (provided) cap plugs to prevent contamination.  Remove the plugs if the 
entries are to be used. 

For specific details including mounting hole dimensions, refer to Figure 1.  The suggested mounting 
height for all station enclosures is 54 inches (137 cm) up to the centerline of the enclosure. 

For continued IP 66 protection, torque setting for securing the amplifier to the enclosure should be 10 to 
12 in-lbs. or 1.13 to 1.36 N-m. 

 

Figure 1.  Model 7325-106 Enclosure Mounting Details 

Summary of Contents for 7325-106

Page 1: ...rsations on up to five party lines simultaneously The Model 7325 106 is constructed of cast aluminum and is extremely weatherproof and corrosion resistant It is equipped with terminal strips for conne...

Page 2: ...a factor Mounting The Model 7325 106 Weatherproof Metallic Enclosure is supplied with pre drilled cable openings and dual 1 25 inch conduit hubs located on both the top and bottom For these four entri...

Page 3: ...coustic feedback to the handset microphone However while the handset is in use for party line conversations the paging speaker is live to enable paging calls from other stations To disable the mute fe...

Page 4: ...Pub 42004 370E Model 7325 106 Multi Party Amplifier Enclosure Page 4 of 6 f standard ioms current release 42004 instr manuals 42004 370e doc 09 13 Figure 2 Wiring Diagram...

Page 5: ...side the enclosures and can cause system faults It may become necessary to re terminate some or all of the enclosures in a system If so strip the wires back to clean copper and connect only one wire t...

Page 6: ...nnections Internal screw type barrier terminal blocks External controls Rotary selector switch Dimensions 14 50 H 10 38 W 9 6 D inches 368 3 263 6 244 mm Temperature range operating and storage 22 F t...

Page 7: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: