Specifications 

Construction/finish................................................................................. Cast aluminum/gray polyurethane 

Mounting...............................................................  Wall or column, four 1/2-inch mounting feet with slots 

Connections ...............................................................................Internal screw-type barrier terminal blocks 

Dimensions.......................................... 15.25 H 

×

 15.25 W 

×

 9.375 D inches (387.4 

×

 387.4 

×

 238.1 mm) 

Temperature range (operating and storage)........................................... (-4º F to +140º F) -20º C to +60º C 

Shipping weight .............................................................................................................  75 lbs. (34.02 kg) 

Enclosure............................................................................................................................. IP66/Type 4X 

Approvals 

ATEX Certified ...............................................................................................

ll

 2 G Ex d [ib] IIB + H

2

 T6 

Applicable standards......................................................... EN 50014:1997, A1+A2:1999, EN50020:2002, 

 

 

EN 60079-0:2006 and EN 60079-1:2004 

CE Mark ...........................................................Complies with Low Voltage Directive 73/23/EEC, and the 
 

EMC Directive 89/336/EEC amended by the Directive 93/68/EEC. 

Certificate No. DEMKO 05 ATEX 0526157X 
Notified Body Id No. 0539 
UL International DEMKO A/S 
Lyskear 8 
DK-2730 Herlev 
Denmark 

 

Summary of Contents for 707-001-EX

Page 1: ...lifier Enclosure is a component of the 700 Series Page Party system It is constructed of cast aluminum and is extremely weatherproof and corrosion resistant This enclosure is equipped with terminal st...

Page 2: ...Install and tighten all cover bolts to 30 ft lbs Make certain no cover bolts are omitted Use only those bolts supplied with the enclosure When installing an add on station consult the appropriate sys...

Page 3: ...s only applicable approval labeling on the exterior The enclosure itself has 12 cover mounting bolts located around the perimeter and a set of aluminum hinges located on the left side See Figure 2 Out...

Page 4: ...plifier The amplifier bridging plate is hinged on one side and attached on the opposite side with two 10 32 screws For system cable installation the screws to this plate must be removed and the bridgi...

Page 5: ...pable of being rotated 90 This allows for top and bottom mounting feet or side to side mounting feet The enclosure ships with the mounting feet in the top to bottom configuration for ease of installat...

Page 6: ...age 6 of 11 s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 703l2a doc 11 07 Cable Entries Refer to Figure 5 for the EX cable gland entries Ensure any unused openings are sea...

Page 7: ...nd completely to the terminal block An improper termination may result in diminished station performance See Figure 6 CAUTION For safe operation connect terminal 3 of TB1 to system ground Mutual Mutin...

Page 8: ...Amplifier Enclosure Page 8 of 11 s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 703l2a doc 11 07 Figure 6 Wiring Diagram Operation Refer to GAI Tronics Pub 42004 699L2 for M...

Page 9: ...ier into the connector in the enclosure Check and if necessary adjust the amplifier to maximize performance 4 Reinstall the amplifier in the enclosure Ensure that all gaskets and hardware are in place...

Page 10: ...attached to other stations located nearby are not pointed in your direction If changing the orientation of the other speakers has no effect mutual muting may be required Mutual muting silences all the...

Page 11: ...blocks Dimensions 15 25 H 15 25 W 9 375 D inches 387 4 387 4 238 1 mm Temperature range operating and storage 4 F to 140 F 20 C to 60 C Shipping weight 75 lbs 34 02 kg Enclosure IP66 Type 4X Approvals...

Page 12: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: