Most of the electronic circuitry is located on a single plug-in PCBA, GAI-Tronics Model 69491-401, 
inside the Model 491-204 Station.  The circuitry associated with keypad and sidetone adjustment is 
located on a small PCBA behind the keypad (Model 69491-002).  All these circuits operate from a single 
12 V NEDA 926 lantern battery also contained within the station.  These internal components are shown 
in Figure 3. 

 

Figure 3.  Internal Components 

For each Mine Dial/Page Telephone station, a GAI-Tronics Model 69001-001 Interface PCBA must be 
used.  This assembly is a plug-in printed circuit board measuring approximately 7.5 

×

 4.5 inches (190.5 

×

 

114 mm) and must be mounted in a non-hazardous area within a Model 495-001 Mine Dial/Page 
Telephone Interface Cabinet. 

Summary of Contents for 491-204

Page 1: ...ermissible for use in gassy coal mines by the Mine Safety and Health Administration MSHA of the United States Department of the Labor Approval Number 9B 221 The system is used in conjunction with a touch tone also known as dual tone multi frequency DTMF operated public telephone exchange or a private branch exchange PBX Each station in the system is made up of two components Mine Dial Page Telepho...

Page 2: ... those stations using the system for normal conversations The push button controlled all station page operation is activated automatically in the event of a telephone switchboard failure A single pair of wires connects each Mine Dial Page Telephone to the interface assembly Each interface is connected to the telephone switchboard with another corresponding pair of wires A person using a Mine Dial ...

Page 3: ...ds within the Model 495 001 Mine Dial Page Telephone Interface Cabinet See Figure 1 for a typical system configuration and guidelines on cabling Refer to Pub 42004 198 for installation and cabling of the Model 495 001 Interface Cabinet The Model 491 204 Mine Dial Page Telephone is contained within a corrosion resistant non metallic enclosure measuring approximately 13 10 7 inches 330 254 178 mm no...

Page 4: ...hese stations such as the horn loaded loudspeaker telephone keypad emergency page push button weatherproof seals and stainless steel hardware A pressbar switch is built into the handset and must be pressed whenever the station is in use both talking and listening This control replaces the conventional hang up hookswitch eliminating the possibility of a user leaving the station off hook and thereby...

Page 5: ...on a small PCBA behind the keypad Model 69491 002 All these circuits operate from a single 12 V NEDA 926 lantern battery also contained within the station These internal components are shown in Figure 3 Figure 3 Internal Components For each Mine Dial Page Telephone station a GAI Tronics Model 69001 001 Interface PCBA must be used This assembly is a plug in printed circuit board measuring approxima...

Page 6: ...d to form a seal to the station enclosure While each underground station will have a telephone extension number that number is associated with the line rather than the actual station For Example If two separately connected stations at locations A and B are interchanged the unit brought from location B to location A will respond to the same telephone extension number as the original unit at locatio...

Page 7: ...l tone 2 Dial the desired telephone number 3 Wait until the birdie signal stops then page the desired person s 4 If no one answers after 30 seconds terminate the call the called person s telephone connection returns to ready condition after 30 seconds 5 Release the handset pressbar to terminate the call Paging All Mine Dial Page Telephone Stations All Call 1 Press and hold the handset pressbar whi...

Page 8: ...d is accompanied by a flashing light to assist in locating the telephone in dark areas The flashing light also gives visual notice of the call in high noise areas The flashing light complies with Virginia and West Virginia MSHA regulations The flashing light circuitry connects to the mine dial page telephone circuitry at only four points the two battery binding posts and the two loudspeaker connec...

Page 9: ...nductor Maximum Cable Length No 22 AWG 16 5 ohms per 1000 feet Maximum 0 20 µH foot Maximum 35 pF foot 15 750 feet 3 miles No 18 AWG 7 1 ohms per 1000 feet Maximum 0 20 µH foot Maximum 35 pF foot 31 500 feet 6 miles No 14 AWG 2 8 ohms per 1000 feet Maximum 0 20 µH foot Maximum 35 pF foot 63 000 feet 12 miles Replacement Parts Part Number Description 10415 101 Handset Assembly 12502 101 Replacement...

Page 10: ... of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of the services provided hereunder Warranty Periods Every claim by Buyer alleging a defect in the goods and or services provided hereunder shall be deemed waived unless su...

Reviews: