background image

(Rev. 10/06)

Warranty

Equipment.

  GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any

GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall
comply with the then-current product specifications and product literature, and if applicable, shall be fit
for the purpose specified in the agreed-upon quotation or proposal document.  If (a) Seller’s goods prove
to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose
specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,
Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time
they will be repaired or replaced, at Seller’s option, without charge to Buyer.  Repair or replacement shall
be Buyer’s sole and exclusive remedy.  The warranty period on any repaired or replacement equipment
shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original
equipment was shipped.  In no event shall GAI-Tronics warranty obligations with respect to equipment
exceed 100% of the total cost of the equipment supplied hereunder.  Buyer may also be entitled to the
manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder.  The applicability
of any such third-party warranty will be determined by GAI-Tronics.

Services.

  Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,

shall be performed in accordance with the standard of care with which such services are normally
provided in the industry.  If the services fail to meet the applicable industry standard, GAI-Tronics will
re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided
any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work
site.  Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI-
Tronics warranty obligations with respect to services exceed 100% of the total cost of the services
provided hereunder.

Warranty Periods.

  Every claim by Buyer alleging a defect in the goods and/or services provided

hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty
periods as set forth above.  Provided, however, that if the defect complained of is latent and not
discoverable within the above warranty periods, every claim arising on account of such latent defect shall
be deemed waived unless it is made in writing within a reasonable time after such latent defect is or
should have been discovered by Buyer.

Limitations / Exclusions.

  The warranties herein shall not apply to, and GAI-Tronics shall not be

responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent
caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the
equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the
equipment.  THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND
EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY
OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Return Policy

If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#).  Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number.  If the equipment is under warranty, repairs or a replacement will be made in
accordance with the warranty policy set forth above.  Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.

Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the
Regional Service Center closest to you.

Summary of Contents for 400-003

Page 1: ...cs product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party General Information GAI Tronics Model 400 003 120 V ac and 400 004 230 V...

Page 2: ...ld be in compliance with all regulations This permanently connected apparatus must have an ALL POLE MAINS switch with a contact separation of at least 3 mm in each pole incorporated in the electrical...

Page 3: ...ch other to provide a proper explosion proof joint Clean surfaces by wiping with a clean lint free cloth Make certain no cover bolts are omitted Use only those bolts supplied with the enclosure Recomm...

Page 4: ...of the enclosure The enclosure has an external grounding screw located on the underside of the flange See Figure 2 OFF ON VOLUME PUSH TO CALL GAI TRONICS CORPORATION 400 E Wyomissing Ave Mohnton PA 19...

Page 5: ...voltage wiring in the left side hole and the power wiring through the right side hole Refer to Figure 2 Attach the wires to the terminal blocks located on the PCBA within the enclosure See Figure 4 a...

Page 6: ...400 004 IEC ATEX Zone 1 RigCom Stations Page 6 of 16 f standard ioms current release 42004 instr manuals 42004 460b doc 03 14 Figure 4 RigCom Station PCBA Model 400 003 PCBA shown with Model 400 004...

Page 7: ...one line balance resistor assembly is needed per system For cable runs that are approximately 1219m 4 000 feet or longer it is recommended that the resistor assembly be installed in a junction box cus...

Page 8: ...for a system with less than ten stations using 1 mm2 wiring with stations spaced equidistantly and one station in the call mode at a time For each station in call mode the signal level reduces by half...

Page 9: ...Neutral terminal of the external ac power supply No connection when external ac power supply is not used AC Power GND Ground earth terminal for the ac power must be electrically connected to the chass...

Page 10: ...n Common Line mode Ext Cont 4 Ground reference for call listen control signal for Master Slave operation No connection in Common Line mode or UNBAL audio configuration Shield 5 Ground reference for sh...

Page 11: ...eration If the header is installed in the UNBAL position the assembly is configured for an unbalanced input signal In systems where the external control signal is single ended the system must be set u...

Page 12: ...call switch allows the operator to send a message to another station When not activated the station is in listen mode and the station receives messages from other stations When a station is configure...

Page 13: ...ction of the Slave units through external control wiring When the Master s push to call is not activated the Slave stations are in call mode allowing the Master to monitor the Slave s audio When the M...

Page 14: ...t the equipment from the supply circuit before making any adjustments to the PCBA s settings F1 F2 Fuses WARNING Do not remove fuses when energized Replace with the same type and size fuse for continu...

Page 15: ...terminated Visually inspect the system cable for accidental crossing of cable pairs or grounds Specifications AC Power Voltage Model 400 003 120 V ac 50 60 Hz Model 400 004 230 V ac 50 60 Hz Power con...

Page 16: ...al Temperature range operating and storage 40 C to 60 C 40 F to 140 F Humidity 95 non condensing Outdoor environmental rating IP66 Approvals CE Mark Certificate No Notified Body Id No 0539 Lyskear 8 D...

Page 17: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: