Pub. 42004-449B 

Model 210-001 Corridor Telephone 

Page:  2 of 9 

f:\standard ioms - current release\42004 instr. manuals\42004-449b.doc 
06/11 

 

Install a UL Listed lightning arrestor

 on any phone installed where the phone or phone cable is at 

risk of being exposed to lightning strikes.  The lightning arrestor must be installed as close to the 
phone as possible to maximize the protection.  The lightning arrestor must not be installed within the 
enclosure supplied with the phone. 

 

NEVER touch uninsulated telephone wires or terminals unless the telephone line has been 
disconnected at the network interface. 

 

USE CAUTION when installing or modifying telephone lines. 

 

Install UL Listed telephone line suppressor (customer-supplied) on the telephone line. 

Installation 

Mounting and Wiring Instructions 

1.

 

Use a GAI-Tronics Model 233-001 Security Screwdriver to remove the four tamper-resistant cover 
panel screws. 

2.

 

Remove the front cover assembly to expose the four mounting holes on the mounting panel.  These 
holes accept #10-32 screws (customer provided).  The length of these screws will depend on the 
mounting surface.  See Figure 2. 

 

Figure 2.  Mounting Details 

Summary of Contents for 210-001

Page 1: ...one operation in a rugged package including the following features Volume control handset with a 29 inch swivel armored cord Brushed stainless steel housing Ringer with loudness control Less than 3 in...

Page 2: ...NEVER touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface USE CAUTION when installing or modifying telephone lines Install UL Liste...

Page 3: ...or direct subscriber telephone line to the PCBA terminal strip Figure 3 Telephone Cord Connection to PCBA Terminal Strip 5 Connect the free end of the modular telephone cord to the incoming subscribe...

Page 4: ...e starts at 0 dB and increases to a maximum volume of 18 dB Pressing the pressbar a seventh time will return the volume to 0 dB 3 Dial the desired number 4 After completion of the call place the hands...

Page 5: ...ved to positions 1 and 2 Refer to Figure 6 for the location of J4 Auxiliary Output Each telephone includes one isolated solid state switch capable of switching a maximum of 48 V dc 125 mA or 28 VRMS a...

Page 6: ...nance than others depending on the environment and exposure to airborne contaminants The following maintenance steps should be performed on a regular basis or when corrosion is first noticed on your M...

Page 7: ...n 16 gauge 060 inch Type 304 brushed stainless steel Dimensions 10 00 H 5 50 3 27 D inches 254 139 7 83 1 mm Weight 5 5 lbs 2 5 kg Handset cord G style with armored cord and volume switch Dial pad Chr...

Page 8: ...s equipment uses the following USOC jacks RJ11CIt is recommended that the customer install an ac surge arrester in the ac outlet to which this device is connected This is to avoid damaging the equipme...

Page 9: ...doc 06 11 Replacement Parts Accessories Part No Description 10118 101 Handset assembly 29 inch Armored Cord 51035 005A Replacement Keypad 61504 048 Keypad Cable Assembly 13707 013 Replacement Ringer w...

Page 10: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...