4.9
Auto-learning dose (SAS)
08
The aim of this function is to automatically adjust the average dose of ground coffee (AUTO-
LEARNING); this occurs by means of an algorithm based on three pieces of information detected
by the machine board:
1. Number of coffee grinder pulses during the grinding cycle
2. Max average value of the power consumed by the gearmotor during the coffee brewing cycle
3. Flavour selected by the user
The algorithm compares the maximum average value of the power consumed by the gearmotor
ZLWKWKHYDOXHVKRZQLQWKHWDEOHGHSHQGLQJRQWKHVHOHFWHGÀDYRXULQRUGHUWRFDOFXODWHWKHQHZ
grinding pulse value for the next coffee product.
If the consumption value is less than the minimum current value, the grinding pulses will be in-
creased by 2.
If the consumption value is greater than the maximum current value, the grinding pulses will be
decreased by 4.
If the consumption value falls within the "excessive stress" range, the product is dispensed and
the grinding pulses will be decreased by 10.
If the consumption value falls within the "expel" range, the pad will be expelled and the grinding
pulses decreased by 10.
,IWKHSUHJURXQGÀDYRXULVVHOHFWHGE\WKHXVHUQRPRGL¿FDWLRQLVPDGH
This guarantees that regardless of the coffee type used, the grinding adjustment
and any wear on the grinder blades always remains constant.
Important:
)RUSHUIHFWRSHUDWLRQWKHDGMXVWPHQWLVFDUULHGRXWLQWKHDUHDRIWKH¿HOGVKLJKOLJKWHGLQ
green (A, B and C). When the type or brand of coffee is changed, there may be variations
in the size of the beans and their stickiness or roasting level. This leads to variations in
SRZHUFRQVXPSWLRQP$UHVXOWLQJLQH[FHVVLYHRULQVXI¿FLHQWGRVHVXQWLOWKHDGMXVWPHQW
compensates this change).
Caution: In case of an excessive dose, ground coffee can fall into the dreg drawer.
This is not a fault, but can occur when the machine is switched on or following a
service.
Setting / Status
Power consumption
in mA
The pulse is corrected in the next grinding process
Exceeded in excess
Exceeded in default
A
0LOGÀDYRXU
200 - 300 mA
- 4
+2
B
Medium Flavour
301 - 450 mA
- 4
+2
C
Strong Flavour
451 - 600 mA
- 4
+2
D
Stress
601 - 800 mA
- 4
E
Excessive stress
801 - 1,000 mA
- 10
F
Pad expulsion
> 1000 mA
- 10
Summary of Contents for Accademia
Page 4: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 1 INTRODUCTION...
Page 9: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 13: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 3 USER INSTRUCTIONS...
Page 17: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 4 OPERATING LOGIC...
Page 29: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 5 TROUBLESHOOTING...
Page 42: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 6 STANDARD INSPECTIONS...
Page 45: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 7 DISASSEMBLY...
Page 58: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 8 NOTES...
Page 59: ...ACCADEMIA 08 NOTES GAGGIA Rev 00 March 2010 Page 01 01...
Page 60: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 9 WATER CIRCUIT DIAGRAM...
Page 61: ...ACCADEMIA 09 WATER CIRCUIT DIAGRAM GAGGIA Rev 00 March 2010 Page 01 01...
Page 62: ...GAGGIA Rev 00 March 2010 ACCADEMIA CHAPTER 10 ELECTRICAL DIAGRAM...
Page 63: ...ACCADEMIA 10 ELECTRICAL DIAGRAM GAGGIA Rev 00 March 2010 Page 01 01...