WARNING ‒ Risk of electric shock!
Incorrect installation is dangerous.
▶
Connect and operate the appliance only in accord-
ance with the specifications on the rating plate.
▶
Connect the appliance to a power supply with al-
ternating current only via a properly installed socket
with earthing.
▶
The protective conductor system of the domestic
electrical installation must be properly installed.
▶
Never equip the appliance with an external switch-
ing device, e.g. a timer or remote control.
▶
When the appliance is installed, the mains plug of
the power cord must be freely accessible. If free ac-
cess is not possible, an isolating switch must be in-
tegrated into the permanent electrical installation ac-
cording to the installation regulations.
▶
When installing the appliance, check that the power
cable is not trapped or damaged.
13.6 Information about the installation room
For safe operation, observe the following information
regarding the installation area.
¡
Install the appliance in accordance with the installa-
tion diagram.
¡
Observe the minimum clearance from the side
walls, parts of the cupboard, and to the rear.
13.7 Information about flush installation
With the flush installation, the appliance and worktop
are on one level. There is no unattractive stepping
between the appliance and the worktop.
You can install the appliance in the following
temperature-resistant and waterproof worktops:
¡
Stone worktops
¡
Plastic worktops, e.g. Corian®
¡
Solid wood worktops
Coordinate with the worktop manufacturer when using
other materials.
Installation in compressed-wood worktops is not pos-
sible.
Have all cut-out work on the worktops carried out in a
specialist workshop in compliance with the installation
diagram. The cut-out must be neat and precise since
the cut edge is visible on the surface.
Clean and degrease the cut-out edges with a suitable
cleaning agent. When doing so, observe the usage in-
structions from the silicone manufacturer.
13.8 Installation accessories
Here, you can find an overview of the installation ac-
cessories.
Use the accessories only as specified. The manufac-
turer shall accept no liability if you use the accessories
incorrectly.
Accessories
Order number
Connection strip for sur-
face-mounted installation
VA420010
Connection strip for flush
installation
VA420004
Appliance cover, stainless
steel
VA440010
13.9 Combining multiple appliances
Requirement:
You need a suitable connection strip to
combine several Vario appliances. You can obtain the
connection strip as an optional accessory.
1.
When making the unit cut-out, allow extra space for
the connecting strip between the appliances.
‒
Observe the installation instructions for the con-
nection strip.
2.
If required, install the appliances in individual cut-
outs.
‒
Maintain a bar width of at least 50 mm between
the individual cut-outs.
13.10 Installing the appliance flush with the
frameless induction hobs
1.
For flush installation in combination with frameless
induction hobs, cut out the support edge with
6.5 mm.
2.
Make the unit cut-out in the worktop for one or more
Vario appliances in accordance with the installation
drawing.
‒
Observe the installation instructions for the con-