background image

9

Installing the appliance

If two V

ario appliances are used, the hob ventilator

must be installed between the appliances. If 4-plate
hobs are used, it is recommended to place two
ventilators to the left and right of the hob. Owing to
the high air output, an adequate supply of air is
required. If you have installed a gas appliance
between the hob extractors VL 430/431, the gas
hob has to be fitted with two air baffles LS 330 on
the side of the hob while cooking. The air baffles
not only improve the airflow of the extractor next to
a gas appliance, but also prevent a flame which has
been set to a low level from being extinguished. 
If you have installed the hob extractor only on one
side of the gas appliance, it is sufficient to fit one
air baffle LS 330 on the side facing the extractor. 

Note: do not install this appliance next to a 

VG 411 gas cooker.

The hob ventilator is installed at the side of the

Vario appliance without any gap between the
appliances.

• As standard, the blow-out direction is downward.

Proceed as follows to establish a blow-out opening
at the side: 
– Undo all 5 screws on the connection piece and 

detach the connection piece.

– Undo the screws of the side cover. 
– Screw the connection piece onto the side 

opening and the cover onto the bottom opening.

• Cut out the recess for one or several Vario

appliances in your worktop. Proceed as indicated
on the installation sketch.  

• Peel the protective film off the sealing tape. Stick

the sealing tape to the front and rear of the cut
out, so that half of the tape overlaps on the inside. 

• On the side of the ventilator, press the seal into

the groove provided. 

820

min. 35

min. 50

490

1280

450

80

93

510

162

140

50

140

Ø

125

135

85

Blow-out opening: 

downward or 
at the side

Summary of Contents for VL 431

Page 1: ...Operating and assembly instructions VL 430 431 Hob ventilator...

Page 2: ......

Page 3: ...ge 4 Maintenance Page 4 2 Features Page 5 Features Page 5 Special accessories Page 5 3 Operation Page 6 4 Cleaning and care Page 7 5 Assembly instructions Page 8 11 Important notes on installation Pag...

Page 4: ...rve to ensure your personal safety and the lasting value of your appliance You will find notes on Page 4 that you ought to observe before operating the appliance for the first time The chapters entitl...

Page 5: ...To do this remove the mains plug or actuate the corresponding fuse If the mains plug is not accessible the appliance must be disconnected from the mains by means of the domestic fuse Fire risk It is...

Page 6: ...titled Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order Maintenance The appliance must always be disconnected from the mai...

Page 7: ...ion flaps 2 Metal grease filter 3 Membrane key pad VL 431 only 4 Clamping screw 5 Suction extraction connection AL 400 000 Edge trim RV 050 150 Bifurcated pipe for joining 2 x DN 125 into DN 150 LS 33...

Page 8: ...ng on Press the corresponding membrane key for the required level The indicator light of the chosen level lights 1 Low speed the flaps open 2 High speed Approximately 20 minutes run on time on level 1...

Page 9: ...se order as follows switch appliance to level 1 Insert the grease filter and turn the two retaining hooks down Insert the flap pins on the front into the hole and hook in at the rear at the correct an...

Page 10: ...ntilator Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for com...

Page 11: ...the side facing the extractor Note do not install this appliance next to a VG 411 gas cooker The hob ventilator is installed at the side of the Vario appliance without any gap between the appliances A...

Page 12: ...s of the 4 pole plug We recommend the use of our telescopic wall box TM 180 043 to route exhaust air through the outside wall Installing the edge trim AL 400 000 The edge trim has to be fitted to the...

Page 13: ...on Pay attention to the rating plate data Observe the connecting scheme when connecting the hob ventilator and the fan module 9000029649 en 12 04 EB 11 Connectors VL 431 connecting cable to GB connect...

Page 14: ......

Page 15: ......

Page 16: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 D 81739 M NCHEN Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com...

Reviews: