background image

3

1. Important notes

1.1 For your safety

Damaged 

appliances must not be operated.

The appliance must only be connected by an

authorised specialist

, paying attention to the

relevant regulations of the power supply companies
and the regional construction regulations. 

Also observe the assembly instructions!

Connecting cables

must not come into contact

with hot cooking surfaces.

Hazardous

or explosive substances and vapours

must not be extracted!

The user 

is responsible for expert use and the

perfect condition of the appliance.

Never 

operate the appliance 

without a grease

filter

.

Only ever operate the appliance under
supervision

. The appliance is intended solely for

use in the household and must not be put to any
other uses.

Do not place any objects on the appliance

this will have a detrimental effect on functioning. 
Do not place any objects under the swivel arm
when it is extended. Make sure that there are no
obstacles in the 

swivel and entry range

.

Do not clean 

the appliance with a steam cleaning

apparatus or with water pressure because this
poses a 

risk of short-circuits.

Isolate the appliance from the mains during 

every

maintenance operation

. To do this, remove the

mains plug or actuate the corresponding fuse. If the
mains plug is not accessible, the appliance must be
deenergised by means of the domestic installation
fuse.

In the event of 

malfunctions

, first of all check 

the household fuses. If the malfunction has nothing
to do with the power supply, please contact your 

specialist dealer or your responsible Gaggenau
after-sales service. 

Repairs 

must be carried out 

by authorised specialists, thus ensuring electrical
safety.

After a power failure

, the hob ventilator will not

switch on automatically, but must be reset instead
by any operator action.

When operated next to gas appliances, the 

swivel

arm

must be extended at least to the 

top edge of

the pan

as otherwise the flame of the gas burner

will be impaired. 

Gas appliances

may only be

used next to a hob ventilator when pots and pans
are placed on them! 

Please note that a wok must

not be installed next to a hob ventilator.

No warranty claims

can be lodged 

in the event 

of damage

caused by failure to observe these

instructions.

Caution!

Over-greased filters are a fire risk! Only

ever deep-fry under the extractor under constant
supervision. Pay attention to cleaning the grease
filter on a regular basis. 

Fire risk! 

It is not permitted to flambé meals next

to a hob ventilator that is in operation.

You may only ever use a grill or a deep fryer at 
the same time as the hob ventilator if it is under
constant 

supervision.

This will involve a fire risk!

When the ventilator is installed next to gas
appliances, swivelling of the boom in the direction
of the gas must be prevented by an additionally
fitted pin (see assembly instructions). 

Caution! The appliance may get very hot! 
Risk of burns!

Technical modifications reserved.

Summary of Contents for VL 051-907

Page 1: ...Operating and assembly instructions VL 051 907 Automatically extendible hob ventilator 3 ...

Page 2: ...rinciple Page 5 2 1 Structure of the appliance Page 5 2 2 Control panel Page 5 2 3 Accessories Page 5 3 Operation Page 6 4 Cleaning and care Page 7 8 5 Maintenance Page 9 6 Assembly instructions Page 10 15 6 1 Technical data Page 10 6 2 Important notes Page 10 6 3 Electrical connection Page 11 6 4 Installation next to a gas hob Page 11 6 5 Installation Page 12 15 ...

Page 3: ...ons conscientiously before operating it for the first time The instructions contain important notes on use installation and maintenance of the appli ance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on Page 4 that you ought to observe before operating the appli...

Page 4: ... event of malfunctions first of all check the household fuses If the malfunction has nothing to do with the power supply please contact your specialist dealer or your responsible Gaggenau after sales service Repairs must be carried out by authorised specialists thus ensuring electrical safety After a power failure the hob ventilator will not switch on automatically but must be reset instead by any...

Page 5: ... rating plate for possible damage and warranty cases Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are acces sories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter entitled Cleaning and care Before operating the appliance for the first time c...

Page 6: ...p 8 Power level control knob with the positions 0 1 2 3 after running stage and grease filter indication You can order the following special accessories VV 200 000 connecting trim AR 070 051 flat Aluflex duct app 40 cm long AS 081 051 attachment plate for GB 031 AS 090 051 2 deflectors for installation with flat duct 2 Structure and operating principle 3 Fig 2 Fig 3 1 3 4 5 6 7 8 2 ...

Page 7: ...put level having been set as from the roasting position the connected fan module automatically runs at a basic level Switching off Turn the Power level control knob to the 0 position on the left Turn the Height adjustment knob to the left to retract the boom The boom turns automatically to its defined starting position in the trough After running Turn the control knob to the left to the After runn...

Page 8: ...grease filters have to be cleaned You can clean the metal grease filters in a dish washer at a maximum temperature of 65 C To do this place the grease filters in the dishwasher in such a way that it is cleaned completely Clean the the grease filter at least once a month Proceed as follows Turn the Height adjustment control knob to the right to extend the boom slightly By doing so you can detach th...

Page 9: ...e boom slightly By doing so you can detach the cover easily Detach the cover Turn up the two retaining clips and remove the grease filter from the appliance Place the two included protective covers on the tube opening to make sure that no small parts will fall into the suction pipe Using a suitable tool undo the 3 cap nuts Remove the protective cover Insert in the reverse order Caution Only clean ...

Page 10: ...less not functioning then please contact your specialist dealer or your responsible Gaggenau after sales service Specify the appliance type To this end have a look at the rating plate which is included with the operating and assembly instructions 5 Maintenance Repairs must only be carried out by authorised specialists thus ensuring the safety of the appliance Improper tampering will render all war...

Page 11: ...er or an open hearth is operated in the same room as the one in which the wall hood is installed Adequate ventilation of the room must be ensured whenever a hob ventilator is operated simultaneously with devices that are operated with non electrical energy Official regulations must be observed with regard to removal of the exhaust air The applicable regulations of the power supply companies and th...

Page 12: ...nce can now only be operated when the window is open Important the window switch must only be connected by an authorised specialist 6 4 Installation next to a gas hob Pay attention to the following notes if you wish to install a gas range next to the hob ventilator A locking bolt must be installed in the hob ventilator to prevent the boom from swivelling over the gas range Extend the unit Position...

Page 13: ...uring rail lie on the worktop and that the centre marking of the securing rail is precisely flush with the centre marking on the worktop Fig 8 When installed in a stone worktop the securing rail must be adhered with a suitable adhesive Make sure that the securing rail is fitted at a right angle to the surface of the worktop Remove the protective film from the included sealing tape and stick the se...

Page 14: ...the VL 051 so that it will protrude into the attachment plate by no more than 10 mm Stick the included sealing tape onto the base plate of the VL 051 around the pipe connection piece Place the VL 051 with the pipe connection piece directly in one of the openings of the AS 081 In the event of a greater distance between VL 051 and AS 081 you can bridge the space between them with a flexible aluminiu...

Page 15: ...ob ventilator into the worktop Make sure that the engaging lugs on the appliance lie exactly on the clamping springs Press the appliance firmly into the worktop The engaging lugs on the appliance snap into the clamping springs At the front fix the hob clamping element onto the worktop from below until the appliance is pressed on evenly Fig 14 If the worktop is less than 36 mm thick place the hob c...

Page 16: ...fan module Now lower the hob ventilator into the worktop Make sure that the engaging lugs on the appliance lie exactly on the clamping springs Press the appliance firmly into the worktop The engaging lugs on the appliance snap into the clamping springs At the front fix the hob clamping element onto the worktop from below until the appliance is pressed on evenly Fig 17 If the worktop is less than 3...

Page 17: ...GAGGENAU HAUSGERÄTE GMBH CARL WERY STR 34 81739 MÜNCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com ...

Reviews: