WARNING ‒ Risk of electric shock!
Incorrect repairs are dangerous.
▶
Repairs to the appliance should only be carried out
by trained specialist staff.
▶
Only use genuine spare parts when repairing the
appliance.
▶
If the power cord of this appliance is damaged, it
must be replaced with a special connection cable,
which is available from the manufacturer or his Cus-
tomer Service.
WARNING ‒ !
Incorrect installation is dangerous.
▶
Connect and operate the appliance only in accord-
ance with the specifications on the rating plate.
▶
The protective conductor system of the domestic
electrical installation must be properly installed.
▶
Never equip the appliance with an external switch-
ing device, e.g. a timer or remote control.
▶
When the appliance is installed, the mains plug of
the power cord must be freely accessible. If free ac-
cess is not possible, an all-pole isolating switch
must be installed in the permanent electrical installa-
tion according to the installation regulations.
▶
When installing the appliance, check that the power
cable is not trapped or damaged.
Only an appliance which has been correctly installed in
accordance with these installation instructions can be
used safely. The installer shall be liable for damages in-
curred as a result of incorrect installation.
26.5 Notes on the installation
Observe the following installation instructions.
¡
Improper installation, connection or incorrect install-
ation may lead to loss of the warranty.
¡
You can only install the induction hob above draw-
ers or ovens with fan ventilation.
¡
Do not install refrigerators, dishwashers, non-ventil-
ated ovens or washing machines underneath the
appliance.
¡
The clearance between the extractor hood and the
hob must correspond at least to the clearance spe-
cified in the installation instructions for the extractor
hood.
¡
The worktop must be level, horizontal and stable.
Follow the instructions provided by the worktop
manufacturer.
¡
If the thickness of the worktop does not comply with
the specifications, reinforce the worktop using a fire-
and water-resistant material until it reaches the min-
imum thickness. Otherwise, sufficient stability cannot
be guaranteed.
¡
The worktop into which you install the hob should
be able to withstand loads of approx. 60 kg. If ne-
cessary, strengthen the worktop with heat- and wa-
ter-resistant material.
¡
Only check that the hob is level once it has been in-
stalled.
26.6 Instructions for the electrical
connection
In order to safely connect the appliance electrically, ob-
serve this information.
¡
Check the household wiring before connecting the
appliance. Ensure that there is sufficient fuse protec-
tion for the household wiring. The voltage and fre-
quency of the appliance must match the electrical
installation (see rating plate).
¡
Ensure that the power supply is properly earthed,
that the fuse protection is sufficient and the cable
and wiring system in the building is sufficiently di-
mensioned for the electrical power of the appliance.
¡
Route the connection cable in such a way that it
does not touch the hot casing.
¡
Use only the connection cable that is supplied with
the appliance or is provided by technical customer
service.
¡
This appliance complies with the EC interference
suppression regulations.
¡
The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡
Ensure that the protection against contact is guaran-
teed during installation.
¡
Only a qualified electrician may connect appliances
without a plug. They are subject to the requirements
of the local electricity provider. We recommend in-
stalling a residual-current-operated circuit-breaker
(RCCB) in the appliance's power supply circuit.
¡
Carry out the electrical connection in accordance
with the installation instructions. The appliance may
be damaged if it is not connected correctly.
¡
The manufacturer shall assume no liability for mal-
functions or damage resulting from incorrect elec-
trical wiring.
26.7 Information about flush installation
With the flush installation, the appliance and worktop
are on one level. There is no unattractive stepping
between the appliance and the worktop.
You can install the appliance in the following
temperature-resistant and waterproof worktops:
¡
Stone worktops
¡
Plastic worktops, e.g. Corian®
¡
Solid wood worktops
Coordinate with the worktop manufacturer when using
other materials.
Installation in compressed-wood worktops is not pos-
sible.
Have all cut-out work on the worktops carried out in a
specialist workshop in compliance with the installation
diagram. The cut-out must be neat and precise since
the cut edge is visible on the surface.
Clean and degrease the cut-out edges with a suitable
cleaning agent. When doing so, observe the usage in-
structions from the silicone manufacturer.
To level the appliance, do not use supports at indi-