12
Technical data (gas)
Burners: super strong burner
Level 1 low flame
< 1 MJ (0.28 kW)
Level 2 full inner flame
< 2 MJ (0.56 kW)
Level 3 small outer flame
plus level 2 full inner flame 5.5 MJ (1.53 kW)
Level 4 full flame
18 MJ (5.0 kW)
Gas connection:
R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
conical-cylindrical
Technical data, gas
Technical data (electrical)
Rated consumption
0.8 W
Voltage
220-240 V
Frequency
50-60 Hz
Technical modifications reserved.
6. Technical data / Table
Countries
AU
AU
Gas family
Natural gas
Propane gas
Gas type
N
X
Pressure
1.0 kPa (10 mbar)
2.75 kPa (27.5 mbar)
Outer burner, full
1.95
1.10 A
Outer burner Bypass
0.88
0.57
Inner burner, full
Nr. 10
Nr. 3
Inner burner Bypass
0.51
0.31
Air gap adj / outer [mm]
2
0
Air gap adj / inner [mm]
open
open
∑ Power
18 MJ (5 kW)
18 MJ (5 kW)
∑ Consumption
0.55 m
3
/h
364 g/h