18
8.1 Technical data
Total rating:
2.3 kW
Fuse:
10 Ampère
Appliance dimensions:
288 x 510 x 198.5 mm
11
5
/
16 x
20
1
/
16 x
7
13
/
16
”
8.2 Important notes on assembly
The installing techician
is responsible for
perfect functioning of the appliance at its
installation location. He must explain the operating
principle of the appliance to the user with
reference to the operating instructions. He must
draw the user's attention as to how to isolate the
appliance from the mains whenever necessary.
Any damage
caused by failure to observe these
instructions cannot be recognised.
If, after installation,
not all poles of the appliance
can be isolated from the mains by removing a plug,
an isolating device with a contact gap of at least
3 mm (e.g. a fuse) must be permanently installed.
Note:
do not install the appliance directly next to a
steam cooker!
The deep fryer
may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures.
Pay attention to the
“Important notes"
(Chapter 1).
There must be
a door in the base cabinet
so as to
enable you to operate the oil drain valve.
Technical modifications without notice.
Electrical connection
The appliance
must only be connected by an
authorised electrician
, paying attention to all
relevant regulations
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
Plug must be rated not less than type 6-15 P
(2-pole 3-wire grounding).
Only a qualified electrician should install this
appliance.
Pay attention to the data on the rating plate.
The mains connecting cable must at least
correspond to the type SJTO 3x16 AWG 105°C
(oil resisting).
You are advised to install a socket outlet earthed in
accordance with regulations approximately 70 cm
(27
1
/
2
”) above the floor behind the appliance. This
must still be accessible after installation.
If damaged, the mains cable must be replaced by a
special mains connecting cable. The mains
connecting cable must only be connected by the
manufacturer or the manufacturer's after-sales
service.
8. Assembly instructions
VF 230-610
FDxxxx
AC 208/220-240 V
60 Hz
2100/2300W
10A