20
Countries
AU
AU
Gas family / Gas type
Natural gas / N
Propane gas / X
Pressure
1.0 kPa (10 mbar)
2.75 kPa (27.5 mbar)
Nozzle, full burn, outer
1.68
1.05
Nozzle, low burn, outer
0.70
0.45
Nozzle, full burn, inner
0.42
0.29
Nozzle, low burn, inner
0.42
0.28
Air gap adjustm. outer [mm]
4
2
Air gap adjustm. inner [mm]
open, fixed
open, fixed
T
otal output (5 burners)
59 MJ (16.5 kW)
62 MJ (17.2 kW)
Nozzle table large burner