16
Extraction mode unit with internal remote fan unit
AR 400 743
1
Attach the exhaust air pipe directly to the remote
fan unit’s air pipe connector
(A)
.
2
Connect it to the air extractor opening
(B)
.
3
Seal the joints appropriately.
Extraction mode units without internal remote fan unit
AR 400 743
1
Unscrew the connecting pieces from the cover
plate in the ventilation hood. Secure the exhaust air
pipe to the connecting piece. Screw the connecting
piece to the cover plate in the ventilation hood.
2
Connect it to the air extractor opening.
3
Seal the joints appropriately.
Connecting the power supply
1
Plug the mains plug into the grounded socket.
2
If a fixed connection is required, please follow the
instructions in the
Electrical Connection
section.
Attaching flue duct
9
WARNING
Risk of injury
Components inside the appliance may have sharp
edges. Wear protective gloves.
1
Remove the protective foil from both flue ducts.
2
Fit the upper flue duct.
Hook both side panels onto the angle brackets and
screw them in at both sides.