background image

AW 221190CN

Gaggenau

zh

操作与安装说明

en

Operating and installation instructions

嘉格纳

Summary of Contents for AW 221190CN

Page 1: ...AW 221190CN Gaggenau zh en Operating and installation instructions...

Page 2: ...2 1 Fig 1 GAS 1 ELECTRO zh 03 18 en page 19 34...

Page 3: ...3 4 4 4 5 5 5 6 7 7 8 8 8 9 11 12 12 12 13 14 14 15 16 16 17 18...

Page 4: ...4 2002 96 EC WEEE F 1 E FD...

Page 5: ...5...

Page 6: ...6 4 Pa 0 04 mbar Technische Regeln Gasinstallation TRGI 50 mm 2 15 1 5 kW 2...

Page 7: ...7 550 mm 1 650 mm 1...

Page 8: ...8 min 126 mm min 580 mm max 1 445 mm min 170 mm 170 mm...

Page 9: ...9 1 2 3 Int 0 Int 2 1 2 3 Int 2 2 0 0 0...

Page 10: ...10 Int 1 2 3 3 4 2 Int 2 1 2 3 Int 10 10 5 0 1 2 3 0 F 30 F F...

Page 11: ...11 1 2...

Page 12: ...12 1 2 3 1 2 2 1 2 3 4...

Page 13: ...13 1 2 3 4 1 2 3 4 5...

Page 14: ...14 150 mm 150 mm 150 mm 120 mm 150 mm 177 cm2 120 mm 113 cm2 150 mm 120 mm...

Page 15: ...15 3 mm LS 1 30 m EC...

Page 16: ...16 Poroton 40 kg 1 2 3 2x 8 mm 2x 8 mm 4 5 3 Nm...

Page 17: ...17 1 1 2 2 3 3 1 2 3 4 5...

Page 18: ...GB 29539 2013...

Page 19: ...ng modes 24 Exhaust air mode 24 Circulating air mode 24 Operating procedure 25 Cleaning and care 27 Removing and installing the grease filters 28 Removing and installing the metal mesh grease filters...

Page 20: ...ure that the old appliance is kept childproof until it is disposed of Before using the appliance for the first time Note These operating instructions apply to several appliance models It is possible t...

Page 21: ...ustomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isol...

Page 22: ...bove gas hobs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the...

Page 23: ...e due to deposits on the grease filter Do not leave pans frying pans or deep fat fryers unattended if you are cooking food with oils or fats e g chips Overheated oils or fats can easily ignite A risk...

Page 24: ...vated carbon filter and conveyed back into the kitchen An activated carbon filter must be installed to bind odours in circulating air mode see Removing and installing the grease filters The complete i...

Page 25: ...uld be pressed when browning and frying in an open pan If you have switched on the hood by selecting the intensive level it will be switched off again automatically after 2 hours If you press the Int...

Page 26: ...ou can activate this function by simultaneously pressing the 0 key and depending on the required extraction capacity the 1 2 or 3 key This mode of operation is indicated by alternating illumination of...

Page 27: ...bsorb the grease particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The funct...

Page 28: ...culating air mode Under normal operation daily 1 to 2 hours the activated carbon filters must be replaced approximately 2x year The activated carbon filter is available from specialist outlets custome...

Page 29: ...e of the same type and equivalent power see rating plate Note When inserting halogen bulbs do not touch the glass tube Therefore use a clean cloth when inserting the bulb 3 Reinsert the bulb cover 4 R...

Page 30: ...ong rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses ma...

Page 31: ...the earthed socket as directly as possible behind the flue duct The earthed socket should be connected via its own circuit If the earthed socket is no longer accessible following installation of the...

Page 32: ...pacity Ensure that the depth of the drilled holes corresponds with the length of the screws Ensure that the wall plugs are secure Max weight 40 kg Design subject to modification in line with technical...

Page 33: ...the holes for the safety screws Detach the extractor hood drill holes for the safety screws and press in wall plugs flush with the wall 2 Attach the extractor hood and screw in the safety screws tigh...

Page 34: ...GB 29539 2013...

Page 35: ...35 AD220182 AD220110 AD220312 AD220322 AD221312 AD221322...

Page 36: ...Gaggenau Hausger te GmbH Carl Wery Stra e 34 D 81739 M nchen www gaggenau com 9000766017 EB 9308...

Reviews: