background image

1.1 For your safety

– Damaged appliances must not be operated.
– The appliance must only be connected by an

authorised specialist

, paying attention to 

the relevant regulations of the power supply
companies and the regional construction
regulations. 

Also observe the assembly instructions!

– Connecting cables must not come into contact

with hot cooking surfaces.

– Do not operate the extractor hood without

inserted lamps.

– Never operate the appliance without a grease

filter.

– Hazardous or explosive substances and vapours

must not be extracted!

– The user is responsible for expert use and the

perfect condition of the appliance.

– Only ever operate the appliance under super-

vision.

Caution!

Over-greased filters are a fire risk!

Only ever deep-fry under the extractor under
constant supervision. Be sure to clean the
grease filter on a regular basis and change the
activated charcoal filter. 

Fire risk!

Do not flambé meals under the

extractor hood!

– Operation of the extractor hood above a hearth

for solid fuels, which poses a fire risk (e.g. sparks)
is only permitted, if the hearth possesses a

closed and fixed lid

. The current local

regulations must be obeyed. This does not apply
to gas hobs and gas cookers.

– Hobs may only be used under the extractor hood

when pots and pans are placed on them!

– When using more than 3 gas-operated rings at

the same time, please operate the extractor
hood at level 2 or higher. This prevents a build-
up of heat in the appliance.

– For safety reasons, do not place any heavy

objects on the top of the appliance.

– Do not clean the appliance with a steam

cleaning apparatus or with water pressure
because this poses a 

risk of short-circuits

.

– Isolate the appliance from the mains during

every maintenance operation. To do this, remove
the mains plug or actuate the corresponding
fuse.
If the mains plug is not accessible, the appliance
must be switched off at fuse point.

– Repairs must be carried out by authorised

specialists, thus ensuring electrical safety.

– No warranty claims can be lodged in the event

of damage caused by failure to observe these
instructions.

– Adequate incoming air must be ensured if a

wood, coal, gas or oil heater or an open hearth is
operated in the same room as the one in which
the hood is installed.

– Safe operation is possible whenever the partial

vacuum in the place where the firing equipment
is installed does not exceed 4 Pa (0.04 mbar).
This can be achieved whenever the air needed
for combustion is able to enter through openings
that cannot be sealed, for example in doors,
windows, incoming/exhaust air wall boxes or
other technical means.

– If the appliance is to be operated only with the

window open (to ensure adequate incoming air),
you can use the 

window switch

.

A switch (normally open) is fitted on the window.
On the appliance, this switch is connected to the
window switch terminal on the main electronics.
The appliance can now only be operated when
the window is open. 

Important:

the window switch must only be

connected by an authorised specialist.
Note: the light function works without restriction.

– After a power failure, the extactor will not go on

again automatically. You can recommence
operation by turning a knob or by pressing any
key. 

Technical modifications reserved.

3

1. Important notes

Summary of Contents for AW 211

Page 1: ...Operating and Assembly Instructions AW 200 AW 201 AW 202 AW 210 AW 211 Extractor Hood ...

Page 2: ......

Page 3: ... 4 1 1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly instructions Page 12 17 6 1 Technical data Page 12 6 2 Installation Page 12 17 ...

Page 4: ...notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on page 4 that you ought to observe before operating the appliance for the first time The chapters entitled Structure and operating principle and Operation w...

Page 5: ...pliance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the corresponding fuse If the mains plug is not accessible the appliance must be switched off at fuse point Repairs must be carried out by authorised ...

Page 6: ... to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order 1 3 About use The appliance is intended solely for use in the household and must not ...

Page 7: ...lation duct AD 011 012 for ceiling heights of 2 25 2 64 m AD 011 022 for ceiling heights of 2 64 3 03 m Installation accessories for circulating air mode Stainless steel design ventilation duct AD 010 112 for ceiling heights of 2 36 2 64 m AD 010 122 for ceiling heights of 2 64 3 03 m Aluminium design ventilation duct AD 011 112 for ceiling heights of 2 36 2 64 m AD 011 122 for ceiling heights of ...

Page 8: ...ration by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan levels Three fan speeds and one intensive speed are available see Fig 5 You set the fan level required for each respective cooking situation by pressing the function selector keys 1 2 3 or Int Fig 4 Fig 5...

Page 9: ...ress the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like to end the intensive level before the five minutes have elapsed press the 0 key Motor off or select a different level see Fig 8 It is possible to switch off the extraction function at any time by pres...

Page 10: ...ff time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour You can activate this function by simultaneously pressing the 0 key and depending on the required extraction capacity the 1 2 or 3 key s...

Page 11: ...ds out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported vertically to allow food or rinsing residues to drain off If possible the inner parts of the housing should be wiped out in hot rinsing water when replacing the filters Caution when cleaning the inside ...

Page 12: ...n smells in the circulating air mode In normal use 1 to 2 hours daily the activated charcoal filter must be replaced approximately once a year If no activated charcoal filter is installed kitchen smells will not be eliminated Replacing the activated charcoal filter remove the stainless steel grease filters Push in the clips on the side of the activated charcoal filter and remove the activated char...

Page 13: ... tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use Risk of burns Detach the ring from the lamp cover Note make sure that the glass will not fall out Fig 16 Pull out the lamp Fig 17 Defective lamps must only be replaced by lamps of the same type 12 V...

Page 14: ...0 mm 6 2 Installation The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood The minimum distance from the cooking surface to the bottom edge of the wall hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the wall hood is 650 mm for gas appli...

Page 15: ...e The condensate separator must still be acciessible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Stainless steel design ventilation duct AD 010 012 for ceiling heights of 2 25 2 64 m AD 010 022 for ceiling heights of 2 64 3 03 m Aluminium design ventilation duct AD 011 012 for ceiling heights of 2...

Page 16: ...can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction function is realised by an external fan module We recommend the fan modules GB 032 107 or GB 052 053 140 from our Gaggenau range the extractor s electronic circuitry is optimised for these fan modules...

Page 17: ...d fix the two hooks d with the countersunk screws c Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the other drill holes Note pay attention to any special accessories that you may have to fit Screw on the retaining bracket for the chimney paneling Detach the grease filters Hang the hood on the two ho...

Page 18: ...nsitive metal surfaces Fit the top chimney duct unit into the base Make sure that the fastening holes on the side are at the top Put both chimney duct units onto the hood Pull the top chimney duct unit up into its final position and secure it with 2 screws on the ceiling holder Fig 23 Note avoid scratches when pulling the elements apart by placing the assembly template for example over the edge of...

Page 19: ... Fig 24 Establish the electrical connection Stainless steel chimney only AD 010 112 122 pull the protective film off the chimney s trims Note avoid damaging the sensitive metal surfaces Fit the top chimney duct unit into the base Make sure that the fastening holes on the side are at the top Put both chimney duct units onto the hood Pull the top chimney duct unit up into its final position and secu...

Page 20: ...Gaggenau Hausgeräte GmbH Carl Wery Straße 34 D 81739 München www gaggenau com 9000209513 EB 8609 en ...

Reviews: