Networked operation
Several appliances can be networked together. The light
and blower on each of the appliances are operated
synchronously.
Connect the appliances in series via the connector
sockets X1 and X2 (equal value). The sequence of the
networking does not have any effect. If the enclosed
network cables are too short, use a commercially
available network cable (min. Cat. 5, shielded).
Maximum number of networked appliances: 20. Total
length of all of the network cables: 131 feet (40 m).
During the initial installation, a qualified electrician must
check that the system functions correctly.
If one of the networked appliances fails (power
interruption, network cable disconnected), this leads to
the blower function being blocked for the entire system.
All of the buttons on the appliance flash.
When changing the configuration, the system must be re-
initialized:
1.
Unscrew the cover plate.
2.
Press and hold the reset button until both LEDs light
up continuously (approx. 5 seconds). Then release the
button within 5 seconds.
3.
Screw on the cover plate.
4.
After initialization, have a qualified electrician check
that the system functions correctly.
Connect Electrical Supply
9
WARNING
Before you connect an electrical cord for
permanent connection or turn on power supply,
make sure all controls are in the OFF position.
9
WARNING
Risk of electric shock!
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during
installation.
Attach flexible conduit to the junction box. The junction
box must be accessible after installation.
To facilitate serviceability, the flex conduit should be
routed to allow for temporary removal of the appliance.
Connect the wires from the appliance conduit to the
junction box supply wires in proper phase:
▯
black (L)
▯
white (neutral)
▯
green (ground)
Check the Installation
9
WARNING
Before you connect an electrical cord for
permanent connection or turn on power supply,
make sure all controls are in the OFF position.
Switch on the circuit breaker.
Verify that elements function properly.
Removing the appliance
Disconnect the appliance from the power supply. Remove
the control cable. Undo the exhaust connections. Pull out
the appliance.