The following note applies to extractor hood
AH 532-190 or AH 532-120 only; these models
do not have an integrated fan:

The extractor hood can only be used in exhaust air
mode. The exhaust air is conveyed upwards through
an externally attached fan via a ventilation shaft or
directly into the open air through the outer wall.  

The extraction function is realised by an external
fan module. We recommend the fan modules 
GB 032-107 or GB 052/053-140 from our Gaggenau
range; the extractor's electronic circuitry is
optimised for these fan modules.

For the electrical connection between the extractor
hood and external fan see installation instructions
for the external fan. 

For safety reasons, if the connecting cable to 
the external fan has been damaged, it must be
replaced by the manufacturer or the after sales
service or similarly qualified persons.

14

Summary of Contents for AH 530-120

Page 1: ...Operating and assembly instructions AH 530 190 120 AH 532 190 120 Extractor hood...

Page 2: ...190 AH 532 120 Preface 1 Important notes Page 3 4 1 1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Pa...

Page 3: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Page 4: ...poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the corresponding fuse If the mains plug is not acce...

Page 5: ...to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter Cleaning and...

Page 6: ...ing heights of 2 20 2 66 m LK 530 020 for ceiling heights of 2 66 3 15 m Aluminium design ventilation duct LK 530 011 for ceiling heights of 2 20 2 66 m LK 530 021 for ceiling heights of 2 66 3 15 m F...

Page 7: ...or off regardless of whether the wall extractor is in operation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting...

Page 8: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Page 9: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Page 10: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported ver...

Page 11: ...an lift the glass plates singly with a blunt object e g handle of a wooden spoon to detach them with greater ease If they are extremely soiled the glass plates can be cleaned in a dishwasher at a maxi...

Page 12: ...e Improper tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortl...

Page 13: ...installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 700 mm The wall hood was conceived for the exha...

Page 14: ...e To prevent the ingress of water e g condensate or rain water from an uncovered exhaust air shaft our condensate separator RV 060 150 must be installed in the exhaust air line The condensate separato...

Page 15: ...The extraction function is realised by an external fan module We recommend the fan modules GB 032 107 or GB 052 053 140 from our Gaggenau range the extractor s electronic circuitry is optimised for th...

Page 16: ...ix the two hooks d with the countersunk screws c Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the o...

Page 17: ...re at the top Put both chimney duct units onto the hood Pull the top chimney duct unit up into its final position and secure it with 2 screws on the ceiling holder Fig 22 Note avoid scratches when pul...